Hostname: page-component-586b7cd67f-2brh9 Total loading time: 0 Render date: 2024-11-24T09:43:02.175Z Has data issue: false hasContentIssue false

Fabrication of micro-scale fracture specimens for nuclear applications by direct laser writing

Published online by Cambridge University Press:  26 February 2018

Mike P.C. Taverne
Affiliation:
Department of Mechanical Engineering, University of Bristol, Bristol, BS8 1TR, UK Department of Electrical and Electronic Engineering, University of Bristol, Bristol BS8 1UB, UK
Xu Zeng
Affiliation:
Department of Mechanical Engineering, University of Bristol, Bristol, BS8 1TR, UK Department of Electrical and Electronic Engineering, University of Bristol, Bristol BS8 1UB, UK
Katrina A. Morgan
Affiliation:
Optoelectronics Research Centre, University of Southampton, Southampton SO17 1BJ, UK
Ioannis Zeimpekis
Affiliation:
Optoelectronics Research Centre, University of Southampton, Southampton SO17 1BJ, UK
Chung-Che Huang
Affiliation:
Optoelectronics Research Centre, University of Southampton, Southampton SO17 1BJ, UK
Ying-Lung D. Ho
Affiliation:
Department of Electrical and Electronic Engineering, University of Bristol, Bristol BS8 1UB, UK
Mahmoud Mostafavi
Affiliation:
Department of Mechanical Engineering, University of Bristol, Bristol, BS8 1TR, UK
Anton Shterenlikht*
Affiliation:
Department of Mechanical Engineering, University of Bristol, Bristol, BS8 1TR, UK
*
Get access

Abstract

The structural integrity of nuclear fission and fusion power plant components is the focus of this research. The state of the art is using micro scale specimens milled with a focussed ion beam (FIB). Because of their very low volume such specimens can be lab tested, even when irradiated to low or medium level of activity. This offers a possibility of testing multiple specimens to investigate stochastic effects, e.g. effects of irradiation on the shift of the ductile to brittle transition. However, FIB milled specimens suffer from Ga contamination, to the degree that the validity of fracture data obtained on such specimens is questionable. We propose to use nano-additive manufacturing as an alternative to FIB for making micro scale fracture specimens. A combination of two-photon polymerization and electrodeposition and sputtering was used to manufacture micro-scale Brazilian disk fracture specimens (CBD), which are free from Ga and thus better suited for the study of irradiation effects on structural integrity. In this study Ni CBD specimens were made with 30 µm diameter and up to 13 µm thickness. The slot width varied between 1 µm to 2.9 µm width the corresponding slot length of between 7.5 µm and 8 µm. Consecutive FIB characterization shows that the specimens have polycrystalline microstructure with sub-µm grains. The work is ongoing making W CBD specimens and on reducing the slot width and using chemical vapor deposition fabrication.

Type
Articles
Copyright
Copyright © Materials Research Society 2018 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Klimenkov, M., Juntsch, U., Rieth, M., et al. , Nuclear Materials and Energy 14 (2016).Google Scholar
Nagata, S., Katsui, H., Hoshi, K., et al. , Journal of Nuclear Materials 442 328332 (2013).CrossRefGoogle Scholar
Grieveson, E. M., Armstrong, D. E. J., Xu, S., and Roberts, S.G., J. Nucl. Mater. 430, 119124 (2012).CrossRefGoogle Scholar
Mostafavi, M., Bradley, R., Armstrong, D. E. J., and Marrow, T. J., Sci. Rep. 6 (2016).Google Scholar
Thompson, K., Gorman, B., Larson, D., van Leer, B., and Hong, L., Microsc. & Microanalysis 12, 1736 (2006).CrossRefGoogle Scholar
Wang, Z., Kato, T., Hirayama, T., Kato, N., Sasaki, K., and Saka, H., Appl. Surf. Sci. 241, 8086 (2005).CrossRefGoogle Scholar
Jany, B.R., Szajna, K., Nikiel, M., Wrana, D., Trynkiewicz, E., Pedrys, R., Krok, F. Appl. Surf. Sci. 327, 8692 (2015).CrossRefGoogle Scholar
Mayer, J., Giannuzzi, L.A., Kamino, T. and Michael, J., MRS Bulletin 32, 400407 (2007).CrossRefGoogle Scholar
Stratulat, , Armstrong, D. E. J., Roberts, S. G., Corrosion Sci. 104, 916 (2016).CrossRefGoogle Scholar
von Freymann, G, Ledermann, A., Thiel, M., Staude, I., Essig, S., Busch, K. and Wegener, M., Adv. Funct. Mater. 20, 1038 (2010).CrossRefGoogle Scholar
Chen, L.-F., Taverne, M. P. C., Zheng, X., Lin, J.-D., Oulton, R., Lopez-Garcia, M., Ho, Y.-L. D., Rarity, J. G., Opt. Express 23, 2656526575 (2015)CrossRefGoogle Scholar
Williams, G. I., Hunt, M., Boeheme, B., Traverne, M., Ho, Y.-L. D., Giblin, S., Read, D. E., Rarity, J. G., Allenspach, R., and Ladak, S., Nano Res. (2017). doi:10.1007/s12274-017-1694-0.Google Scholar