Article contents
Utilization of sound signals to evaluate the risk of sloppingin oxygen converters⋆
Published online by Cambridge University Press: 18 January 2011
Abstract
Ternium Siderar has recently installed a commercial sensor that measures the soundoriginated during blowing. A proper analysis of this signal may give valuable informationabout the slopping tendency of the heat. Data from more than 4000 heats were collected andthoroughly analyzed. The influences of the materials charged and of their compositions onthe slag slopping tendency were investigated. Based on these results, an application toevaluate the risk of slopping for given process conditions was developed.
Keywords
- Type
- Research Article
- Information
- Copyright
- © EDP Sciences
References
Références
- 4
- Cited by