Hostname: page-component-cd9895bd7-jn8rn Total loading time: 0 Render date: 2024-12-24T17:14:52.407Z Has data issue: false hasContentIssue false

Some calculations on the γ-ray dose produced by a 14 Mev. betasynchrotron using an internal target

Published online by Cambridge University Press:  24 October 2008

D. J. Allen-Williams
Affiliation:
Department of RadiotherapeuticsUniversity of Cambridge
R. K. Appleyard
Affiliation:
Department of RadiotherapeuticsUniversity of Cambridge

Extract

Relations are derived between the dose in r./min. delivered by the γ-ray beam from a betasynchrotron and the mean electron current which is incident on the internal target. Comparison with experiment shows that multiple passage of electrons through the target probably plays an important part in production of the γ-ray beam. Some possible effects connected with the multiple passage of electrons are discussed.

Type
Research Article
Copyright
Copyright © Cambridge Philosophical Society 1949

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

(1)Goward, F. K. and Barnes, D. E.Nature, London, 158 (1946), 413.CrossRefGoogle Scholar
(2)Schiff, L. I.Phys. Rev. 70 (1946), 87.CrossRefGoogle Scholar
(3)Heitler, W.The Quantum Theory of Radiation (Oxford 1936), p. 170.Google Scholar
(4)Heitler, W. Op. cit. pp. 157, 170.Google Scholar
(5)Kerst, D. W. and Serber, R.Phys. Rev. 60 (1941), 53.CrossRefGoogle Scholar