Hostname: page-component-cd9895bd7-jkksz Total loading time: 0 Render date: 2024-12-24T17:02:10.359Z Has data issue: false hasContentIssue false

An electrical method for the determination of short-period activities and its use in the evaluation of the half-life of 12B

Published online by Cambridge University Press:  24 October 2008

J. V. Jelley
Affiliation:
St John's CollegeCambridge
E. B. Paul
Affiliation:
Selwyn CollegeCambridge

Extract

Equipment has been designed and constructed for the interruption of the ion beam in a high-voltage accelerating tube and for the detection and measurement of the period of short-lived radioactive elements. This method has been applied to the measurement of the half-life of 12B which has been found to be 27 ± 2 msec. The reaction 15N(n, α)12B has been detected.

Type
Research Article
Copyright
Copyright © Cambridge Philosophical Society 1948

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

(1)Cassels, J. M. and Latham, R.Nature, London, 159 (1947), 367.CrossRefGoogle Scholar
(2)Crane, H. R., Delsasso, L. A., Fowler, W. A. and Lauritsen, C. C.Phys. Rev. 47 (1935), 887.CrossRefGoogle Scholar
(3)Becker, R. A. and Gaerttner, R. E.Phys. Rev. 56 (1939), 854.Google Scholar