Hostname: page-component-cd9895bd7-gvvz8 Total loading time: 0 Render date: 2024-12-25T05:12:24.413Z Has data issue: false hasContentIssue false

Optimization of the non-normal incidence, transient pumped plasma X-ray laser for laser spectroscopy and plasma diagnostics at the facility for antiproton and ion research (FAIR)

Published online by Cambridge University Press:  28 February 2007

TH. KUEHL
Affiliation:
GSI, Darmstadt, Germany University of Mainz, Mainz, Germany
D. URSESCU
Affiliation:
GSI, Darmstadt, Germany
V. BAGNOUD
Affiliation:
GSI, Darmstadt, Germany
D. JAVORKOVA
Affiliation:
GSI, Darmstadt, Germany
O. ROSMEJ
Affiliation:
GSI, Darmstadt, Germany
K. CASSOU
Affiliation:
Université Paris Sud/LIXAM, Paris, France
S. KAZAMIAS
Affiliation:
Université Paris Sud/LIXAM, Paris, France
A. KLISNICK
Affiliation:
Université Paris Sud/LIXAM, Paris, France
D. ROS
Affiliation:
Université Paris Sud/LIXAM, Paris, France
P. NICKLES
Affiliation:
MBI, Berlin, Germany
B. ZIELBAUER
Affiliation:
GSI, Darmstadt, Germany University of Mainz, Mainz, Germany MBI, Berlin, Germany
J. DUNN
Affiliation:
Lawrence Livermore National Laboratory, Livermore, California
P. NEUMAYER
Affiliation:
GSI, Darmstadt, Germany Lawrence Livermore National Laboratory, Livermore, California
G. PERT
Affiliation:
York University, York, United Kingdom

Abstract

Intense and stable laser operation with Ni-like Zr and Ag was demonstrated at pump energies between 2 J and 5 J energy from the PHELIX pre-amplifier section. A novel single mirror focusing scheme for the TCE x-ray laser (XRL) has been successfully implemented by the LIXAM/MBI/GSI collaboration under different pump geometries. This shows potential for an extension to shorter XRL wavelength. Generation of high quality XRL beams for XRL spectroscopy of highly charged ions is an important issue within the scientific program of PHELIX. Long range perspective is the study of nuclear properties of radioactive isotopes within the FAIR project.

Type
Research Article
Copyright
© 2007 Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Cassou, K., Kazamias, S., Ros, D., Ple, F., Jamelot, G., Klisnick, A., Lundh, O., Lindau, F., Persson, A., Wahlström, C.-G., De Rossi, S., Joyeux, D., Zielbauer, B., Ursescu, D. & Kuehl, Th. (2006). Optimization towards high average brightness soft X-ray laser pumped in grazing incidence. Opt. Lett. 32, 139141.Google Scholar
Henning, W.F. (2004). The future GSI facility. Nucl. Instr Meth. B 214, 211215.Google Scholar
Hoffmann, D.H.H., Blazevic, A., Ni, P., Rosmej, O., Roth, M., Tahir, N., Tauschwitz, A., Udrea, S., Varentsov, D., Weyrich, K. & Maron, Y. (2005). Present and future perspectives for high energy density physics with intense heavy ion and laser beams. Laser Part. Beams 23, 395395.Google Scholar
Neumayer, P., Alvarez, J., Becker-de Mos, B., Borneis, S., Brueck, K., Gaul, E.W., Haefner, C., Janulewicz, K.A., Kuehl, Th., Marx, D., Reinhard, I., Tomaselli, M., Nickles, P.V., Sandner, W. & Seelig, W. (2001). X-ray laser spectroscopy on lithium-like ions. Proc. SPIE Int. Soc. Opt. Eng. 4505, 236.Google Scholar
Neumayer, P., Bock, R., Borneis, S., Brambrink, E., Brand, H., Caird, J., Campbell, E.M., Gaul, E., Goette, S., Haefner, C., Hahn, T., Heuck, H.M., Hoffmann, D.H.H., Javorkova, D., Kluge, H.J., Kuehl, Th., Kunzer, S., Merz, T., Onkels, E., Perry, M.D., Reemts, D., Roth, M., Samek, S., Schaumann, G., Schrader, F., Seelig, W., Tauschwitz, A., Thiel, R., Ursescu, D., Wiewior, P., Wittrock, U. & Zielbauer, B. (2005). Status of PHELIX laser and first experiments. Laser Part. Beams 23, 385.Google Scholar
Neumayer, P., Seelig, W., Cassou, K., Klisnick, A., Ros, D., Ursescu, D., Kuehl, Th., Borneis, S., Gaul, E., Geithner, W., Haefner, C. & Wiewior, P. (2004). Transient collisionally excited X-ray laser in nickel-like zirconium pumped with the PHELIX laser facility. Appl. Phys. B 78, 957.Google Scholar
Pert, G.J. (2006). Optimizing the performance of nickel-like collisionally pumped X-ray lasers. Phys. Rev. A 73, 033809.Google Scholar
Schaumann, G., Schollmeier, M.S., Rodriguez-Prieto, G., Blazevic, A., Brambrink, E., Geissel, M., Korostiy, S., Pirzadeh, P., Roth, M., Rosmej, F.B., Faenov, A.Y., Pikuz, T.A., Tsigutkin, K., Maron, Y., Tahir, N.A. & Hoffmann, D.H.H. (2005). High energy heavy ion jets emerging from laser plasma generated by long pulse laser beams from the NHELIX laser system at GSI. Laser Part. Beams 23, 503512.Google Scholar
Stoehlker, T., Backe, H., Beyer, H., Bosch, F., Braeuning-Demian, A., Hagman, S., Ionescu, D., Jungmann, K., Kluge, H.-J., Kozhuharov, C., Kuehl, Th., Lisen, D., Mann, R., Mokler, P. & Quint, W. (2003). Status and perspectives of atomic physics research at GSI: The new GSI accelerator project. Nucl. Instr. Meth. B 205, 156.Google Scholar