Hostname: page-component-586b7cd67f-dlnhk Total loading time: 0 Render date: 2024-11-27T20:34:15.044Z Has data issue: false hasContentIssue false

Mono versus dual isocentric technique for breast cancer radiotherapy: evaluation of planning, dosimetry and treatment delivery

Published online by Cambridge University Press:  23 September 2020

Tabassum Wadasadawala*
Affiliation:
Department of Radiation Oncology, Tata Memorial Centre, ACTREC, Homi Bhabha National Institute, Navi Mumbai, India
Shirley Lewis
Affiliation:
Department of Radiotherapy and Oncology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India
Utpal Gaikwad
Affiliation:
Department of Radiation Oncology, Tata Memorial Centre, ACTREC, Homi Bhabha National Institute, Navi Mumbai, India
Umesh Gayake
Affiliation:
Department of Radiation Oncology, Tata Memorial Centre, ACTREC, Homi Bhabha National Institute, Navi Mumbai, India
Reena Phurailatpam
Affiliation:
Department of Radiation Oncology, Tata Memorial Centre, ACTREC, Homi Bhabha National Institute, Navi Mumbai, India
Santosh Tambe
Affiliation:
Department of Radiation Oncology, Tata Memorial Centre, ACTREC, Homi Bhabha National Institute, Navi Mumbai, India
Rajiv Sarin
Affiliation:
Department of Radiation Oncology, Tata Memorial Centre, ACTREC, Homi Bhabha National Institute, Navi Mumbai, India
*
Address for Correspondence: Dr Tabassum Wadasadawala, MD, DNB, Professor (Radiation Oncology), Advanced Center for Treatment Research and Education in Cancer (ACTREC), Tata Memorial Centre, CISF Road, Near Central Park, Kharghar, Navi Mumbai, India-410210; Phone: +91-22-27405079; Fax: +91-22-27405061. E-mail: [email protected]; [email protected]

Abstract

Aim:

To compare the dosimetry and reproducibility of set-up with monoisocentric technique (MIT) and dual isocentric technique (DIT) in adjuvant breast radiotherapy (RT).

Material and methods:

Breast cancer patients treated with MIT or DIT were retrospectively studied. The organ-at-risk dose was compared between two groups. All patients underwent set-up verification with an electronic portal imaging device, and set-up time was recorded for each fraction. Treatment reproducibility was assessed in terms of systematic and random error.

Results:

Twenty patients were included (11 right and 9 left-sided tumours) and ten received whole breast RT, while the rest received chest wall RT. Overall, the mean heart dose was less with MIT (0.40 versus 0.79, p = <0.001) as well as in left-sided tumours (0.37 versus 0.98, p = 0.003). The maximum dose at the field junction was significantly higher with DIT (43 Gy, 107%, p = 0.003). The maximum total error was 1 cm in lateral for supraclavicular field and 8 mm in superior–inferior in tangents for both techniques. There was no difference in set-up errors between the two techniques.

Findings:

MIT resulted in better dose homogeneity at the field junctions and reduced mean heart dose as compared to DIT. MIT is safe for implementation in clinical practice for breast cancer treatment.

Conclusion:

This study is one of the few studies comparing MIT with DIT in terms of the dosimetry and the first one to compare set-up errors between the two techniques. The ease of set-up and better dosimetry with MIT was achieved.

Type
Original Article
Copyright
© The Author(s), 2020. Published by Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Ferlay, J, Colombet, M, Soerjomataram, I, et al. Estimating the global cancer incidence and mortality in 2018: GLOBOCAN sources and methods. Int J Cancer 2019; 144 (8): 19411953.CrossRefGoogle ScholarPubMed
Malvia, S, Bagadi, S A, Dubey, U S, Saxena, S. Epidemiology of breast cancer in Indian women. Asia-Pac J Clin Oncol 2017; 13 (4): 289295.CrossRefGoogle ScholarPubMed
Group EBCTC. Effect of radiotherapy after breast-conserving surgery on 10-year recurrence and 15-year breast cancer death: meta-analysis of individual patient data for 10 801 women in 17 randomised trials. Lancet 2011; 378 (9804): 17071716.10.1016/S0140-6736(11)61629-2CrossRefGoogle Scholar
McGale, P, Taylor, C, Correa, C, et al. Effect of radiotherapy after mastectomy and axillary surgery on 10-year recurrence and 20-year breast cancer mortality: meta-analysis of individual patient data for 8135 women in 22 randomised trials. Lancet 2014; 383 (9935): 21272135.Google ScholarPubMed
Zeidan, Y H, Habib, J G, Ameye, L, et al. Postmastectomy Radiation Therapy in Women with T1-T2 Tumors and 1 to 3 Positive Lymph Nodes: Analysis of the Breast International Group 02-98 Trial. Int J Radiat Oncol Biol Phys 2018; 101 (2): 316324.10.1016/j.ijrobp.2018.01.105CrossRefGoogle Scholar
Whelan, T J, Olivotto, I A, Parulekar, W R, et al. Regional Nodal Irradiation in Early-Stage Breast Cancer. N Engl J Med 2015; 373 (4): 307316.10.1056/NEJMoa1415340CrossRefGoogle ScholarPubMed
Poortmans, P M, Collette, S, Kirkove, C, et al. Internal Mammary and Medial Supraclavicular Irradiation in Breast Cancer. N Engl J Med 2015; 373 (4): 317327.10.1056/NEJMoa1415369CrossRefGoogle ScholarPubMed
Sloan, L, Alcorn, S. Acute and Late Skin Toxicity from Breast Radiation. Toxicities of Radiation Treatment for Breast Cancer. Springer, 2019: 522.CrossRefGoogle Scholar
Jagsi, R, Griffith, K A, Boike, T P, et al. Differences in the acute toxic effects of breast radiotherapy by fractionation schedule: comparative analysis of physician-assessed and patient-reported outcomes in a large multicenter cohort. JAMA Oncol 2015; 1 (7): 918930.10.1001/jamaoncol.2015.2590CrossRefGoogle Scholar
Demirci, S, Nam, J, Hubbs, J L, Nguyen, T, Marks, L B. Radiation-induced cardiac toxicity after therapy for breast cancer: interaction between treatment era and follow-up duration. Int J Radiat Oncol Biol Phys 2009; 73 (4): 980987.10.1016/j.ijrobp.2008.11.016CrossRefGoogle ScholarPubMed
Lingos, T I, Recht, A, Vicini, F, Abner, A, Silver, B, Harris, J R. Radiation pneumonitis in breast cancer patients treated with conservative surgery and radiation therapy. Int J Radiat Oncol Biol Phys 1991; 21 (2): 355360.CrossRefGoogle ScholarPubMed
Olsen, N K, Pfeiffer, P, Johannsen, L, Schrøder, H, Rose, C. Radiation-induced brachial plexopathy: neurological follow-up in 161 recurrence-free breast cancer patients. Int J Radiat Oncol Biol Phys 1993; 26 (1): 4349.CrossRefGoogle ScholarPubMed
Dobbs, H J. Radiation therapy for breast cancer at the millennium. Radiother Oncol 2000; 54 (3): 191200.10.1016/S0167-8140(00)00137-7CrossRefGoogle ScholarPubMed
Marshall, M G. Three-field isocentric breast irradiation using asymmetric jaws and a tilt board. Radiother Oncol 1993; 28 (3): 228232.10.1016/0167-8140(93)90062-DCrossRefGoogle Scholar
Klein, E E, Taylor, M, Michaletz-Lorenz, M, Zoeller, D, Umfleet, W. A mono isocentric technique for breast and regional nodal therapy using dual asymmetric jaws. Int J Radiat Oncol Biol Phy 1994; 28 (3): 753760.10.1016/0360-3016(94)90204-6CrossRefGoogle ScholarPubMed
Banaei, A, Hashemi, B, Bakhshandeh, M. Comparing the monoisocentric and dual isocentric techniques in chest wall radiotherapy of mastectomy patients. J Appl Clin Med Phy 2015; 16 (1): 130138.10.1120/jacmp.v16i1.5069CrossRefGoogle ScholarPubMed
Jooladi, N, Mahdavi, S R, Nedaei, H, et al. A comparison of dose distribution parameters between conventional and mono isocentric methods of breast irradiation in phantom by gafchromic EBT2 films. Basic Clin Cancer Res 2014; 6 (2): 3541.Google Scholar
White, J., Arthur, D., Buchholz, T.A., et al. Breast cancer atlas for radiation therapy planning: consensus definitions. RTOG. http://www.rtogorg/CoreLab/ContouringAtlases/BreastCancerAtlasaspx. Accessed on 20th January 2020.Google Scholar
van Herk, M. Errors and margins in radiotherapy. Semin Radiat Oncol 2004; 14 (1): 5264.10.1053/j.semradonc.2003.10.003CrossRefGoogle ScholarPubMed
Van Herk, M, Remeijer, P, Rasch, C, Lebesque, J V. The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phy 2000; 47 (4): 11211135.10.1016/S0360-3016(00)00518-6CrossRefGoogle ScholarPubMed
Kagkiouzis, J, Platoni, K, Kantzou, I, et al. Review of the three-field techniques in breast cancer radiotherapy. JBUON 2017; 22 (3): 599605.Google ScholarPubMed
Urbańczyk, H, Hawrylewicz, L, Ganowicz, M, et al. The “one-isocenter-quarter-beam” technique as a radiotherapy of breast cancer patients. Rep Pract Oncol Radiother 2005; 10 (6): 307312.10.1016/S1507-1367(05)71104-4CrossRefGoogle Scholar
Gałecki, J, Grudzień-Kowalska, M, Kawczyńska, M, et al. Experiences with the mono isocentric irradiation technique in breast cancer patients after conservative surgery. Nowotwory J Oncol 2004; 54 (5): 474.Google Scholar
Chaikh, A, Fayolle, S, Gabelle-Flandin, I, et al. A quantitative method to implement and to assess the single isocenter technique for breast cancer radiation therapy. Int J Cancer Ther Oncol 2015; 3 (3): 10.14319.CrossRefGoogle Scholar
Assaoui, F, Toulba, A, Nouh, M, et al. Mono-isocentric technique in the breast cancer and organ at risk tolerance. J Nucl Med Radiat Ther S 2012; S2: 010.Google Scholar