Hostname: page-component-586b7cd67f-t7fkt Total loading time: 0 Render date: 2024-11-30T23:14:46.383Z Has data issue: false hasContentIssue false

Magnetothermodynamics: measurements of the thermodynamic properties in a relaxed magnetohydrodynamic plasma

Published online by Cambridge University Press:  19 February 2018

M. Kaur*
Affiliation:
Swarthmore College, Swarthmore, Pennsylvania 19081, USA
L. J. Barbano
Affiliation:
Swarthmore College, Swarthmore, Pennsylvania 19081, USA
E. M. Suen-Lewis
Affiliation:
Swarthmore College, Swarthmore, Pennsylvania 19081, USA
J. E. Shrock
Affiliation:
Swarthmore College, Swarthmore, Pennsylvania 19081, USA
A. D. Light
Affiliation:
Swarthmore College, Swarthmore, Pennsylvania 19081, USA
D. A. Schaffner
Affiliation:
Bryn Mawr College, Bryn Mawr, Pennsylvania 19010, USA
M. B. Brown
Affiliation:
Swarthmore College, Swarthmore, Pennsylvania 19081, USA
S. Woodruff
Affiliation:
Woodruff Scientific Inc., Seattle, Washington 98103, USA
T. Meyer
Affiliation:
Woodruff Scientific Inc., Seattle, Washington 98103, USA
*
Email address for correspondence: [email protected]
Rights & Permissions [Opens in a new window]

Abstract

We have explored the thermodynamics of compressed magnetized plasmas in laboratory experiments and we call these studies ‘magnetothermodynamics’. The experiments are carried out in the Swarthmore Spheromak eXperiment device. In this device, a magnetized plasma source is located at one end and at the other end, a closed conducting can is installed. We generate parcels of magnetized plasma and observe their compression against the end wall of the conducting cylinder. The plasma parameters such as plasma density, temperature and magnetic field are measured during compression using HeNe laser interferometry, ion Doppler spectroscopy and a linear ${\dot{B}}$ probe array, respectively. To identify the instances of ion heating during compression, a PV diagram is constructed using measured density, temperature and a proxy for the volume of the magnetized plasma. Different equations of state are analysed to evaluate the adiabatic nature of the compressed plasma. A three-dimensional resistive magnetohydrodynamic code (NIMROD) is employed to simulate the twisted Taylor states and shows stagnation against the end wall of the closed conducting can. The simulation results are consistent to what we observe in our experiments.

Type
Research Article
Copyright
© Cambridge University Press 2018 

1 Introduction

The equation of state (EOS) of an ideal gas as derived from statistical mechanics relates pressure, volume and temperature of the gas. Charged particles in a plasma, particularly if there is a strong magnetic field, need not obey an ideal gas EOS. In such a case, one needs to consider the motion of charged particles both along and across the local magnetic field. Measuring the EOS of a magnetized plasma is important for advancing fusion experiments as well as for understanding natural systems such as stellar winds.

The true equation of state in the solar wind, for example, is still unknown. Solar wind plasmas are collisionless and in the supersonic expansion of such plasmas, an anisotropy between perpendicular temperature ( $T_{\bot }$ ) and parallel temperature ( $T_{\Vert }$ ) with respect to the direction of the background magnetic field is observed (Kasper et al. Reference Kasper, Lazarus, Gary and Szabo2003). If the expansion of the solar wind plasma were to be regulated by an adiabatic equation of state, the expected drop in the proton temperature (particularly $T_{\bot }$ ) would be much faster with radius from the Sun (Brown & Schaffner Reference Brown and Schaffner2015) than is measured at 1 AU. This is because the volume of a shell of solar wind plasma increases as the square of the radius, i.e. $r^{2}$ and 1 AU is approximately 200 solar radii. Instead, the effects of collisional age (time measured in units of mean time between collisions) (Bale et al. Reference Bale, Kasper, Howes, Quataert, Salem and Sundkvist2009) and kinetic instabilities (such as firehose and mirror) (Kasper, Lazarus & Gary Reference Kasper, Lazarus and Gary2002) appear to regulate the temperature anisotropy but do not yet account for the thermodynamics of the expansion.

Over the past decades, numerous experiments (Hammer et al. Reference Hammer, Hartman, Eddleman and McLean1988, Reference Hammer, Eddleman, Hartman, McLean and Molvik1991; Molvik et al. Reference Molvik, Eddleman, Hammer, Hartman and McLean1991; Hurricane et al. Reference Hurricane, Callahan, Casey, Celliers, Cerjan, Dewald, Dittrich, Doppner, Hinkel and Berzak Hopkins2014; Park et al. Reference Park, Hurricane, Callahan, Casey, Dewald, Dittrich, Döppner, Hinkel, Berzak Hopkins and Le Pape2014) motivated by fusion applications have been performed to achieve a highly compressed plasma but little has been done to understand the thermodynamics of such systems. Some progress has been made in measuring the EOS of unmagnetized plasma in the context of inertial confinement fusion experiments (Hurricane et al. Reference Hurricane, Callahan, Casey, Celliers, Cerjan, Dewald, Dittrich, Doppner, Hinkel and Berzak Hopkins2014; Park et al. Reference Park, Hurricane, Callahan, Casey, Dewald, Dittrich, Döppner, Hinkel, Berzak Hopkins and Le Pape2014). At the national ignition facility (NIF), a radial compression of an unmagnetized Deuterium–Tritium pellet resulted in a density increase by a factor of 1000. The full NIF EOS is unpublished but includes radiation as well as compressive effects. Similar thorough studies in magnetized plasma have yet to be performed.

Early compression experiments on magnetized plasma were performed at the RACE facility in the 1990s (Hammer et al. Reference Hammer, Hartman, Eddleman and McLean1988, Reference Hammer, Eddleman, Hartman, McLean and Molvik1991; Molvik et al. Reference Molvik, Eddleman, Hammer, Hartman and McLean1991). In these experiments, spheromak-type axisymmetric plasmas were magnetically accelerated to $2500~\text{km}~\text{s}^{-1}$ along 6 m long coaxial electrodes and stagnated in a conical taper. Radial compression of a factor of three and magnetic field amplification by a factor of four were observed. In compression experiments on the Inductive Plasma Accelerator (IPA) device, two axisymmetric field reversed configurations (FRCs) were merged and magnetically compressed to kilovolt ion temperature (Votroubek et al. Reference Votroubek, Slough, Andreason and Pihl2008; Slough, Votroubek & Pihl Reference Slough, Votroubek and Pihl2011). Velocities of $250~\text{km}~\text{s}^{-1}$ were achieved in IPA. Finally, in liner implosion experiments at the Shiva Star facility, dense, initially unmagnetized hydrogen plasma was compressed to megabar pressures inside a magnetically imploded aluminium sphere. A radial compression of a factor of three was observed in the Shiva Star experiments (Degnan et al. Reference Degnan, Alme, Austin, Beason, Coffey, Gale, Graham, Havranek, Hussey and Kiuttu1999). However, an equation of state was not reported in any of these experiments. As compression experiments in magneto-inertial fusion (MIF) (Lindemuth & Kirkpatrick Reference Lindemuth and Kirkpatrick1983; Lindemuth Reference Lindemuth2015, Reference Lindemuth2017) come online, it will be important to understand the EOS of such magnetized plasmas.

Recently, compression experiments were carried out at the magnetized liner inertial fusion (MagLIF) experiment at Sandia (Slutz & Vesey Reference Slutz and Vesey2012; Awe et al. Reference Awe, McBride, Jennings, Lamppa, Martin, Rovang, Slutz, Cuneo, Owen and Sinars2013; Gomez et al. Reference Gomez, Slutz, Sefkow, Sinars, Hahn, Hansen, Harding, Knapp, Schmit and Jennings2014). In these experiments, a 4.6 mm diameter cylinder of deuterium is premagnetized to 10 T, then preheated by a laser pulse to 100 eV and imploded by the Z-machine. Physical scale and temporal duration (100 ns) of these experiments are much larger than that of typical inertial confinement fusion experiments which significantly relaxes constraints on the driver. Final plasma parameters upon compression at MagLIF were as follows: plasma temperature increases to 4 keV, magnetic field to 1000 T, and Deuterium–Deuterium neutron yield of approximately $2\times 10^{12}$ was achieved. These are promising results that could be aided by well-established EOS.

In this paper, the experimental studies in which we have explored the thermodynamics of compressed magnetized plasmas (‘magnetothermodynamics’) using measured plasma parameters, described in Kaur et al. (Reference Kaur, Barbano, Suen-Lewis, Shrock, Light, Brown and Schaffner2018), are presented in detail. In these experiments, we generate a parcel of magnetized, fully relaxed, non-axisymmetric plasma (Woltjer Reference Woltjer1958; Taylor Reference Taylor1985, Reference Taylor1986; Cothran et al. Reference Cothran, Brown, Gray, Schaffer and Marklin2009; Gray, Brown & Dandurand Reference Gray, Brown and Dandurand2013) and observe its compression against a conducting cylinder closed at one end. The plasma parameters are measured during compression and a pressure–volume (PV) diagram is constructed to identify instances of associated ion heating; we call these ‘compressive heating events’. The local magnetohydrodynamic (MHD) and the double adiabatic (CGL) equations of state are tested during compression events, under several experimental conditions. Our aim for these studies is to know whether there is an equation of state that describes the ion compressional heating of such relaxed plasmas. We find that the MHD EOS is not consistent with our observations, while the parallel CGL equation of state is valid for our data. To understand the axial variation of the plasma parameters, a three-dimensional resistive magnetohydrodynamic code (NIMROD) is employed, which shows a helical structure consistent with previous observations (Gray et al. Reference Gray, Brown and Dandurand2013). A Taylor state was observed to stagnate against the end wall of the closed conducting can in the simulations.

The remainder of the paper is organized as follows. In § 2, we review the theory of equations of state for magnetized plasmas, both the MHD EOS and the so-called double adiabatic EOS. In § 3, we describe the experimental set-up of the SSX plasma accelerator. In § 4, we discuss our three principal diagnostics: an ion Doppler spectrometer for sub-microsecond temperature measurements, a HeNe laser interferometer for density measurements and a magnetic probe array for magnetic structure and time-of-flight measurements. In § 5, we present our experimental results, and in § 6, our simulation results are described. A discussion and conclusion are presented in § 7.

2 Theory

Equations of state for magnetized plasmas fall into two categories. In the collisional regime (i.e. $\unicode[STIX]{x1D714}_{ci}\unicode[STIX]{x1D70F}<1$ , where $\unicode[STIX]{x1D714}_{ci}$ and $\unicode[STIX]{x1D70F}$ are the ion cyclotron frequency and Coulomb collision time, respectively), ions suffer multiple collisions before executing a Larmor orbit. In this case, magnetic field plays no role; MHD plasma exhibits an isotropic velocity distribution and can be treated as an ideal gas. The adiabatic EOS for such a plasma can be written

(2.1) $$\begin{eqnarray}\displaystyle \frac{\unicode[STIX]{x2202}}{\unicode[STIX]{x2202}t}\left(\frac{P}{n^{\unicode[STIX]{x1D6FE}}}\right)=0, & & \displaystyle\end{eqnarray}$$

where $P$ and $n$ are the plasma pressure ( $P=nk_{B}T$ ) and density, respectively; $T$ is the plasma temperature. $\unicode[STIX]{x1D6FE}$ is the ratio of heat capacity at constant pressure to heat capacity at constant volume. Its value is given by $\unicode[STIX]{x1D6FE}=(f+2)/f$ , where $f$ is the number of microscopic degrees of freedom. Thus, for an MHD plasma with three degrees of freedom, $\unicode[STIX]{x1D6FE}=5/3$ .

If the collision rate is low (i.e. $\unicode[STIX]{x1D714}_{ci}\unicode[STIX]{x1D70F}>1$ ), ions execute many Larmor orbits before suffering a collision. In this case, the perpendicular ( $P_{\bot }=nk_{B}T_{\bot }$ ) and parallel pressure ( $P_{\Vert }=nk_{B}T_{\Vert }$ ) with respect to the direction of the background magnetic field need not be the same. Because of this anisotropy, the MHD equation of state no longer remains valid. To account for such a situation, Chew, Goldberger and Low proposed a modified set of adiabatic EOS, commonly known as double adiabatic or CGL equations of state (Chew, Goldberger & Low Reference Chew, Goldberger and Low1956):

(2.2) $$\begin{eqnarray}\displaystyle & \displaystyle \frac{\unicode[STIX]{x2202}}{\unicode[STIX]{x2202}t}\left(\frac{P_{\bot }}{nB}\right)=0, & \displaystyle\end{eqnarray}$$
(2.3) $$\begin{eqnarray}\displaystyle & \displaystyle \frac{\unicode[STIX]{x2202}}{\unicode[STIX]{x2202}t}\left(\frac{P_{\Vert }B^{2}}{n^{3}}\right)=0. & \displaystyle\end{eqnarray}$$

Equation (2.2) is related to the constancy of the first adiabatic invariant $\unicode[STIX]{x1D707}=W_{\bot }/B$ and (2.3) is related to the constancy of the second adiabatic invariant, ${\mathcal{J}}=v_{\Vert }L$ ; where $W_{\bot }$ , $v_{\Vert }$ and $L$ are the perpendicular kinetic energy with respect to magnetic field, parallel velocity with respect to magnetic field, and the length of the guiding centre along the field lines, respectively. Equation (2.3) follows from the assumption of constant magnetic flux along a flux tube and fixed number of particles. While deriving (2.2) and (2.3), the plasma oscillations have been neglected as for these plasmas, the plasma frequency is very large compared to the ion cyclotron frequency.

3 Experimental set-up

In these experiments, we produce parcels of magnetized plasma using a coaxial magnetized plasma gun, which is located at one end of the linear Swarthmore Spheromak eXperiment (SSX) device, as shown in figure 1. The diameter of the inner electrode of the gun is 6.2 cm and the outer electrode (i.e. flux conserver) diameter is 15 cm. More details about the plasma gun can be found in earlier publications (Geddes, Kornack & Brown Reference Geddes, Kornack and Brown1998; Brown & Schaffner Reference Brown and Schaffner2014, Reference Brown and Schaffner2015). At the other end of the linear chamber, a closed, tungsten-lined copper can, referred to here as a stagnation flux conserver (SFC), is installed. The SFC is ${\sim}30~\text{cm}$ long and has the same inner diameter as that of the outer electrode. A ${\sim}1~\text{m}$ long quartz tube ( $\text{diameter}=15~\text{cm}$ ) is installed in between the gun and the SFC to accommodate theta-pinch coils for our future experiments. For the present studies, the glass tube has been covered with a copper flux conserving shell having long magnetic soak time ( ${>}200~\unicode[STIX]{x03BC}\text{s}$ ) to provide flux conservation to the magnetized plasma. We maintain a good vacuum using a cryopump. After each vacuum break, the gun and the device are cleaned using He glow discharge to maintain a low-impurity plasma.

Figure 1. A schematic of the experimental set-up. A glass tube has been added in between the gun and the stagnation flux conserver (SFC) and is covered with a copper flux conserving shell. A Permendur magnet rod is installed at the centre of the inner electrode shell. All the three principal plasma diagnostics are located in the SFC at the location of the circle. $T_{i}$ is measured using ion Doppler spectroscopy along the vertical chord and $n$ is measured using HeNe laser interferometry along a horizontal chord. The long ${\dot{B}}$ probe array is aligned along the axis of the SFC. The red lines on the magnetic probe array represent the locations of the ${\dot{B}}$ probes.

Tungsten-lined coaxial electrodes are cleaned by producing a He glow discharge before experiments to obtain good wall conditions. A strong magnetic field ( $\backsim 1~\text{T}$ ) is generated in the inner electrode using an external electromagnet and a strong ferromagnetic core. Hydrogen gas is puffed into the annular region between the two electrodes using gas puff valves. A voltage pulse ( ${\approx}4~\text{kV}$ , 8 kJ) is applied between the two electrodes which ionizes the gas and causes a high current ( $\backsim 100~\text{kA}$ ) to flow through the plasma. $\boldsymbol{J}\times \boldsymbol{B}$ forces accelerate the plasma out of the gun (where $\boldsymbol{J}$ stands for the current density associated with the radial plasma current sheet and $\boldsymbol{B}$ represents the toroidal magnetic field generated due to the current flowing through the inner electrode) and a toroidal self-consistent magnetic object, called a spheromak (Geddes et al. Reference Geddes, Kornack and Brown1998), is formed.

The neutral hydrogen gas density (and hence, plasma density) can be controlled by varying the delay between the gas puff valve and gun. The gas puff valves are similar to those described by Thomas et al. (Reference Thomas, Hwang, Horton, Rogers and Raman1993). Using this scheme, a proper delay will provide only as much gas as is necessary to form the parcels of magnetized plasma. If the delay is too short, i.e. the gun fires too early (in our case, $300~\unicode[STIX]{x03BC}\text{s}$ after the gas puff), there will not be enough hydrogen gas to ionize and this may result in sputtering of the electrode surface. If the delay is too long (e.g. the gun fires $750~\unicode[STIX]{x03BC}\text{s}$ after the gas puff), due to the thermal speed of the gas atoms, some hydrogen gas would leave the gun and enter the glass tube. In such a case, the spheromak will form by ionizing the hydrogen gas present in the annular region; but as soon as it enters the glass tube, due to its interaction with the neutral hydrogen gas, the spheromak will cool. For most of our experiments, the delay between the gas puff valve and the gun has been set between $500$ and $600~\unicode[STIX]{x03BC}\text{s}$ .

The toroidal structure continues to move away from the gun after its formation; the leading edge of the Taylor state moves at $60~\text{km}~\text{s}^{-1}$ whereas the bulk plasma moves at $v\geqslant 40~\text{km}~\text{s}^{-1}$ . The copper sheet wrapped around the glass tube acts as a flux conserver with long aspect ratio for which the predicted minimum energy state is close to the infinite cylinder solution. Therefore, the toroidal structure tilts and relaxes to a non-axisymmetric twisted, force-free minimum energy state, called a Taylor state, within few Alfvén times. This minimum energy state has been well characterized in previous studies (Woltjer Reference Woltjer1958; Taylor Reference Taylor1985, Reference Taylor1986; Cothran et al. Reference Cothran, Brown, Gray, Schaffer and Marklin2009; Gray et al. Reference Gray, Brown and Dandurand2013; Brown & Schaffner Reference Brown and Schaffner2014; Schaffner et al. Reference Schaffner, Lukin, Wan and Brown2014). The inertia of the Taylor state carries it to the other end of the device into the SFC, where the object stagnates and compresses against the end wall; this is where we perform measurements on the compressed plasma.

4 Diagnostics

For these experiments, we rely on three principal diagnostics. While selecting these diagnostics, our goal is to be minimally invasive. For measuring the equations of state, it is important that the measurements perturb the plasma as little as possible. For measurement of ion temperature and plasma density, we use non-invasive diagnostics, ion Doppler spectroscopy and HeNe laser interferometry, whereas for the measurement the local magnetic field, we use a long, axial ${\dot{B}}$ probe array. All these three diagnostics have a high frequency response, ${\geqslant}1~\text{MHz}$ , which is sufficient to resolve the physics of processes lying in the proton cyclotron frequency regime, ${\sim}1.5~\text{MHz}$ for the 1 kG magnetic field in our experiments.

4.1 Ion Doppler spectroscopy

To measure ion temperature with sub-microsecond time resolution, we make use of ion Doppler spectroscopy (IDS). Our IDS system features a 1.33 m (Czerny–Turner) spectrometer which makes use of an echelle grating (with 316 grooves/mm) to achieve high spectral resolution and a 32-channel photomultiplier tube (PMT) array for fast time response (Cothran et al. Reference Cothran, Fung, Brown and Schaffer2006). The plasma light is collected along a vertical chord using a telescope, as shown in figure 2, dispersed on the echelle grating, and is recorded using the PMT array. Our current studies are focused on the evolution of 229.687 nm emission line from $CIII$ -impurity ions present in our plasma (Chaplin et al. Reference Chaplin, Brown, Cohen, Gray and Cothran2009) which we observe at twenty-fifth order over a lifetime of $\simeq 100~\unicode[STIX]{x03BC}\text{s}$ . The proton-impurity ion equilibration time is faster than $1~\unicode[STIX]{x03BC}\text{s}$ and the instrument temperature is 3–5 eV. We are using 16 channels available on the PMT array. A typical lineshape at $60~\unicode[STIX]{x03BC}\text{s}$ is shown in figure 3. The ion temperature obtained from this lineshape is 12 eV and the shift in the Gaussian fit along the negative $x$ -axis indicates a vertical velocity of $11.6~\text{km}~\text{s}^{-1}$ . The time resolution of these measurements is $\backsimeq 1~\unicode[STIX]{x03BC}\text{s}$ and is sufficient to observe any magnetohydrodynamic phenomena.

Figure 2. A cross-sectional view of the set-up along with diagnostics. In ion Doppler spectroscopy, $C_{III}$ line (229.687 nm) is dispersed using an echelle grating and recorded at twenty-fifth order. In laser interferometry, the interference output is passed through a Wollaston prism which generates two outputs $90^{\circ }$ out of phase with each other. The circle indicates the position of the ${\dot{B}}$ probe array, slightly off-centred.

Figure 3. A typical lineshape obtained from the ion Doppler spectroscopy at $60~\unicode[STIX]{x03BC}\text{s}$ using 16 channels on PMT array. The cross-marks in the black colour correspond to the photocurrent and the red colour bars represent their corresponding error bars. The blue line represents the Gaussian fit to the IDS data and the ion temperature obtained from the half-width-full-maxima of this Gaussian lineshape is ${\sim}12~\text{eV}$ .

4.2 HeNe laser interferometry

The line-averaged density of the Taylor state is measured along a horizontal chord using a 632.8 nm HeNe laser quadrature interferometer. The interferometer utilizes a modified Mach–Zehnder configuration and employs a Wollaston prism (Brown & Schaffner Reference Brown and Schaffner2014). Phase shift ambiguities associated with normal interferometers are resolved by circularly polarizing the reference beam. Interference signal is passed through the Wollaston prism which generates two outputs $90^{\circ }$ out of phase with each other to enable density measurements during each shot. The intensity of each Wollaston output is measured by two photo-detectors. During the alignment of the interferometer, we make sure that the two outputs of the Wollaston prism are exactly $90^{\circ }$ out of phase. A typical envelope obtained from the interferometer is shown in figure 4. The initial phase of the measurements is removed from the two signals by considering the fact that at the beginning of the measurements, density of the plasma should be zero. As the time scale of the mechanical vibrations of the system (ms) is much larger than the time scale of the measurements ( $\unicode[STIX]{x03BC}\text{s}$ ), the changes in phase due to the mechanical vibrations can be approximated as linear. This linear change in the data is removed by fitting a straight line to the data points in the range $t<25~\unicode[STIX]{x03BC}\text{s}$ , as the Taylor states consistently arrive at the interferometer after this time. The interferometry chord lies in the same plane as the IDS chord.

Figure 4. A typical envelope obtained from the interferometer detectors to be used in calibration for determining the electron density.

4.3 ${\dot{B}}$ probe array

Along with these two diagnostics, we use a long ${\dot{B}}$ probe array (encased in a domed quartz glass tube of outer diameter 1 cm) along the axis of the SFC. The ${\dot{B}}$ probe array serves to measure the velocity and structure of the Taylor states and has been divided into two sections accordingly: the front and the rear section. Front section has three equally spaced (14.2 cm) single turn probes axially located inside the glass tube for measuring the Taylor state velocity using a time of flight (ToF) technique.

The rear section of the long probe has densely spaced (1.5 cm), single turn probes. These probes measure the magnetic field in two orthogonal directions, perpendicular to the flux conserver axis. These two-directional probes are located inside the SFC and are employed for determining the Taylor state structure. This section of the long probe also has few three-directional probes, which are used to measure the all three components of the local vector magnetic field and hence, to measure the local $\unicode[STIX]{x1D6FD}$ parameter. A three-directional ${\dot{B}}$ probe is nearly co-located with the intersection of IDS and interferometry chords.

Each probe in the long probe array is carefully calibrated using a Helmholtz coil set driven by the same pulsed power supply that energizes the magnetized plasma gun. The ${\dot{B}}$ probe data are recorded at a high cadence (65 MHz) using 14 bit D-Tacq digitizers and numerically integrated using the trapezoidal rule to obtain the absolute magnetic field values.

5 Experimental results

The bulk velocity of the Taylor state is measured using the front three ${\dot{B}}$ probes present in the glass tube on the axial long probe. The velocity of the leading edge of the Taylor state is determined by recording the time when the ${\dot{B}}$ probes start showing magnetic signal due to the plasma. In this way, the leading edge of the Taylor state is found to be moving at ${\approx}60~\text{km}~\text{s}^{-1}$ . For determining the Taylor state bulk velocity, we track one particular structure in each probe data and record the time taken by the structure to reach the different probes. Using the time lag and the known distance between the probes, time of flight velocity of the bulk plasma is obtained. The bulk velocity of the Taylor state from time of flight is found to be ${\sim}37~\text{km}~\text{s}^{-1}$ and is plotted in figure 5. The Taylor state flow speed is consistent with free expansion. The Alfvén speed is ${>}60~\text{km}~\text{s}^{-1}$ ; therefore, the plasma (moving at ${\sim}40~\text{km}~\text{s}^{-1}$ ) stagnating against the end of the SFC is not expected to produce shocks.

Figure 5. Velocity of the Taylor state using time of flight method from three ${\dot{B}}$ probes. The bulk Taylor state velocity is ${\sim}37~\text{km}~\text{s}^{-1}$ whereas its leading edge moves at ${\sim}60~\text{km}~\text{s}^{-1}$ .

As mentioned in § 3, all other measurements are performed on the compressed plasma inside the SFC. A typical set of time traces of plasma density, ion temperature and magnetic field magnitude measured inside the compression volume (SFC) is shown in figure 6. The leading edge of the Taylor state moves at $\approxeq 60~\text{km}~\text{s}^{-1}$ and reaches the SFC at $40~\unicode[STIX]{x03BC}\text{s}$ , indicated by blue colour in figure 6. We observe a rise in plasma density and ion temperature for time windows spanning 40– $48~\unicode[STIX]{x03BC}\text{s}$ , 55– $60~\unicode[STIX]{x03BC}\text{s}$ and 73– $75~\unicode[STIX]{x03BC}\text{s}$ corresponding to compression against the back end of the SFC. The exact mechanism behind the increase in thermal pressure ( $p=nT$ ) at these different times is not fully understood. However, we believe that the initial two events correspond to a compression of the Taylor state after it reaches the stagnation flux conserver. Whereas, the heating event occurring late in time might correspond to the compression of the Taylor state due to the arrival of an additional plasma entering the stagnation flux conserver. We occasionally see an additional plasma plume generated and enter the stagnation flux conserver late in time.

Figure 6. A typical time trace of (a) plasma density, (b) ion temperature and (c) magnetic field measured inside the stagnation flux conserver. The error bars for $T_{i}$ are indicated by the vertical bars at each time value whereas the uncertainty in $n$ and $B$ is ${<}10\,\%$ . The 10 % uncertainty accounts for the errors due to a high frequency buzz present in the interferometer detector signals for density (also can be seen in figure 4) and due to the numerical integration in the magnetic field. Taylor state enters the SFC at ${\approx}40~\unicode[STIX]{x03BC}\text{s}$ (indicated by the blue bar) and then compresses against the closed end of the SFC accompanied by a rise in $T_{i}$ at $40$ , $55$ and $75~\unicode[STIX]{x03BC}\text{s}$ (indicated by the pink bar).

The time trace of magnetic field magnitude in panel (c) of figure 6 is obtained from the three-directional ${\dot{B}}$ probes co-located with the IDS and interferometry chords. Electron temperature, $T_{e}$ has been reported earlier in SSX Taylor states (Brown & Schaffner Reference Brown and Schaffner2014). We have found that $T_{e}$ is around ${\sim}10~\text{eV}$ and is much less temporally dynamic than $T_{i}$ . Since $T_{e}$ is essentially constant during a compression event, it does not contribute towards the EOS and has not been considered for further analysis. Electron thermal speed is ${>}10^{8}~\text{cm}~\text{s}^{-1}$ , but the electron–electron collision mean free path is ${\sim}0.5~\text{mm}$ , which indicates that the parallel electron transport is collisional and diffusive. Nonetheless, during a compressive heating event, electrons rapidly diffuse away from the measurement volume while the ions stay more localized.

The magnetic field vectors from the ${\dot{B}}$ probe array along the SFC axis are plotted at different times, as shown in figure 7. The two solid black lines represent the back end of the flux conserver. The Taylor state enters the SFC from the right. At $43.68~\unicode[STIX]{x03BC}\text{s}$ , one lobe of the helical structure is seen inside SFC (see figure 7 a). The vector rendering confirms the presence of a relaxed helical structure (Gray et al. Reference Gray, Brown and Dandurand2013) inside the SFC. As time progresses, we start seeing a second lobe as well. Two pairs of ${\dot{B}}$ probes are located outside the SFC to see if there is any magnetic flux leakage through the hole at the end wall. Substantially lower signal from these two probe pairs indicates that little flux leaks through the back end of the SFC.

Figure 7. A typical helical structure from the ${\dot{B}}$ probe array along the axis of the SFC at different time instances (for the same shot as figure 6): (a) $t_{1}=43.68~\unicode[STIX]{x03BC}\text{s}$ , (b) $t_{2}=51.48~\unicode[STIX]{x03BC}\text{s}$ , (c) $t_{3}=60.43~\unicode[STIX]{x03BC}\text{s}$ and (d) $t_{4}=74.97~\unicode[STIX]{x03BC}\text{s}$ . The two solid black lines represent the back end of the flux conserver. The twisted Taylor state enters the SFC from right hand side and gets compressed against the back end of the SFC.

From the magnetic fluctuation spectrum of the relaxed Taylor state in the compression volume, we found that the spectrum is dominated by energy at low frequencies and long wavelengths. The spectral index is much steeper for the relaxed object ( $\unicode[STIX]{x1D6FC}<-4$ ) than that observed in turbulence studies during relaxation ( $\unicode[STIX]{x1D6FC}=-2.47$ ) (Schaffner et al. Reference Schaffner, Lukin, Wan and Brown2014). Our primary objective in the present work is to study the additional heating of the fully relaxed Taylor state due to compression.

5.1 Determination of local compression using wavelet analysis

We determine the fractional compression of the relevant volume of plasma by measuring the changes in the dominant axial wavenumber of the magnetic structure. Because the plasma is well described by a helical analytic equilibrium, i.e. a Taylor state (Gray et al. Reference Gray, Brown and Dandurand2013), it is possible to map changes in the local axial wavenumber of the helix directly to changes in the length of a parcel of plasma. We use a continuous wavelet transform of the multi-point magnetic signals to calculate the spatial wavenumber spectrum as a function of time and space. The wavelet transform is analogous to a Fourier transform, but uses basis functions with a finite extent in the transform variable (Torrence & Compo Reference Torrence and Compo1998). We employed a Paul wavelet of order 2 as our mother wavelet function because it matches the qualitative spatial features of the magnetic field in the SFC. Using a wavelet method (as opposed to windowed Fourier transforms) allows us to localize the power (in $z$ ) in an optimal way for each wavenumber, providing a compression measurement specific to the region where the temperature and density are monitored.

At each time step, we calculate a spatial wavelet spectrum of one component of the magnetic field transverse to the axis of the helix and one such wavelet spectrum is shown in figure 8. For illustrative purposes, let $B^{t}(z)=B_{x}(t=t_{i},z)$ for a particular time, $t_{i}$ . There are 18 magnetic probe locations associated with the SFC, each spaced by $\unicode[STIX]{x0394}z=1.5~\text{cm}$ and indexed by the labels $m$ and $m^{\prime }$ . Using this notation, $B^{t}(z)=B^{t}(m^{\prime }\unicode[STIX]{x0394}z)=B_{m^{\prime }}^{t}$ is the field component at position index $m^{\prime }$ at time $t_{i}$ . The spatial wavelet transform at that time is:

(5.1) $$\begin{eqnarray}\displaystyle W_{m}^{t}(s)=\mathop{\sum }_{m^{\prime }=0}^{N-1}B_{m^{\prime }}^{t}\unicode[STIX]{x1D6F9}^{\ast }\left[\frac{(m-m^{\prime })\unicode[STIX]{x0394}z}{s}\right], & & \displaystyle\end{eqnarray}$$

where $\unicode[STIX]{x1D6F9}$ is the mother wavelet function, $s$ is the wavelet scale (whose relationship to $k_{z}$ depends on the particular mother wavelet), $N=18$ is the number of measurement locations and $m$ represents the index of the spatial measurement point corresponding to the centre of the wavelet. $W_{m}^{t}(s)$ thus represents the component of the spatial magnetic structure at time $t_{i}$ represented by a wavelet of scale $s$ centred at $m\unicode[STIX]{x0394}z$ .

Figure 8. The image of the wavelet analysis at a particular time instance for the same shot as figure 6. The colour bar on the right-hand side tells the power in a particular wavenumber. The white dot represents the centroid of the most dominant wavenumber and the hyperbola-like white curve represents the cone of influence below which the wavenumber values are unreliable.

By tracking the peak of the power spectrum, $|W_{m}^{t}(s)|^{2}$ , represented by the white dot in figure 8, we identify the dominant scale as a function of time. As the scale changes, we can identify local changes in the pitch of the helical equilibrium structure corresponding to compression or rarefaction along the axis of the device. The fractional change in volume is simply related to the fractional change in length by the assumption that the plasma fills the device radially: $\unicode[STIX]{x1D6FF}V/V=A\unicode[STIX]{x1D6FF}L/AL=\unicode[STIX]{x1D6FF}L/L$ . The typical wavenumber of the twist in the equilibrium state is $k_{z}\sim 0.04~\text{cm}^{-1}$ , corresponding to a wavelength of $\unicode[STIX]{x1D706}_{z}\sim 25~\text{cm}$ , and typical changes in volume corresponding to compression are of the order of 10–30 %. We found that the observed pitch of the Taylor state from the axial ${\dot{B}}$ probe array is consistent with earlier more detailed measurements (Gray et al. Reference Gray, Brown and Dandurand2013).

5.2 PV diagram

The PV diagram describes the relationship between pressure and volume during any physical process. Using time traces of Taylor state length and plasma pressure (which is the product of plasma density and temperature), we construct a PV diagram. In the PV diagram, we identify the time windows which correspond to ion heating during compression. In other words, when compression and ion heating occur simultaneously, we call this a compressive heating event. A typical PV diagram for one such compression event is shown in figure 9. The PV diagram clearly shows that as the Taylor state compresses, the plasma pressure increases, resulting in a shift from a lower to higher isotherm in the PV diagram. In these experiments, a maximum Taylor state length compression of up to 30 % is observed.

Figure 9. (a) A time trace of effective length (for the same shot as figure 6) of the Taylor state, (b) an associated increase in pressure and (c) a trajectory of the thermodynamic state of the object in a PV diagram for the compression process. Uncertainty in the thermal pressure is $\approxeq 15\,\%$ and is determined by propagating the errors in density and ion temperature. The uncertainty in the length of the Taylor state is ${\approx}10\,\%$ and is determined using the innermost contour of the wavelet analysis (see figure 8). Note that as the volume of the Taylor state decreases the pressure shifts to higher isotherms.

5.3 Equations of state

After the identification of a compressive heating event, the EOS of the compressed plasma is computed to assess the thermodynamics of the magnetized plasma. Because SSX plasmas relax to an equilibrium described by MHD (Cothran et al. Reference Cothran, Brown, Gray, Schaffer and Marklin2009; Gray et al. Reference Gray, Brown and Dandurand2013), one might expect the thermodynamics to be described by the corresponding EOS. To check the validity of equations of state, hundreds of shots are recorded under a variety of gun parameters. In all these shots, compressive heating events are identified on a PV diagram. The compression events, for most of the shots, range from $1$ $2~\unicode[STIX]{x03BC}\text{s}$ in duration.

To determine the general behaviour of the compressed states, we plot the EOS for all the events in figure 10. A set of 192 compression events are used for analysing the EOS with a typical length contraction ranging from 10–40 % and are shown by light blue lines in each panel of figure 10. The MHD EOS for three-dimensional compression ( $\unicode[STIX]{x1D6FE}=5/3$ ), perpendicular and parallel CGL EOS as a function of time are plotted in figures 10(a), 10(b) and 10(c), respectively. The dark blue band in each panel shows the mean with the standard error of the mean represented by the thickness of the band. In figure 10, note that the means of the time derivatives specified by (2.1), (2.2) are clearly non-zero, which indicates that our plasma does not satisfy the MHD and perpendicular CGL EOS. Whereas, the mean of the time derivative specified by (2.3) remains nearly zero during compression which indicates that the parallel CGL EOS is valid for our magnetized plasmas.

Figure 10. Statistical variation of three equations of state for 192 compression events (length contraction ranges from 10–30 %) are shown by light blue lines for: (a) the magnetohydrodynamic equation of state for three-dimensional compression ( $\unicode[STIX]{x1D6FE}=5/3$ ), (b) perpendicular and (c) parallel CGL equations of state as a function of time. The dark blue band in each panel shows the standard error of the mean. Note that the MHD equation of state (a), and the perpendicular version of the CGL EOS (b) have non-zero time derivative. However, the parallel version of the CGL EOS (c) has nearly zero time derivative for most the compression time. Reprinted with permission from Kaur et al. (Reference Kaur, Barbano, Suen-Lewis, Shrock, Light, Brown and Schaffner2018). Copyright 2017 The American Physical Society.

The uncertainty in density and magnetic field is ${\sim}10\,\%$ and the error for $T_{i}$ is shown in second panel of figure 6. When we reconstruct figure 10 along with the individual event error bars for all the three EOS, as shown in figure 11, the error bars for the MHD EOS and perpendicular CGL EOS are not consistent with the zero axes. Whereas, the error bars for the parallel CGL EOS are evenly distributed around the zero axis. We, further, note that our plasma is weakly collisional which could be the reason why the MHD EOS is not valid for our magnetized plasma. As the plasma ion–ion collisionality reduces ( $\unicode[STIX]{x1D714}_{ci}\unicode[STIX]{x1D70F}=0.6$ ), the magnetic field starts to dominate. Because of this, the CGL EOS with proton energy in the parallel direction with respect to the magnetic field seems to describe the behaviour of our plasmas.

Figure 11. Statistical time variation of three equations of state for 192 compression events is shown by the light blue lines for: (a) the MHD EOS for three-dimensional compression, (b) perpendicular and (c) parallel CGL EOS. The dark blue band in each panel shows the standard error of the mean, while the red colour bars represent the error bars in each individual event. It is clear that the error bars for the MHD EOS (a), and the perpendicular version of the CGL EOS (b) are not consistent with the zero axis. However, the parallel version of the CGL EOS (c) error bar is evenly distributed around zero axis.

All the compression events used to construct figures 10 and 11 satisfy the following criteria: (i) length compression should be greater than or equal to 10 %, (ii) compression event should last for more than $1~\unicode[STIX]{x03BC}\text{s}$ and (iii) the PV diagram should demonstrate a transition from a lower to higher isotherm. We treat these events as adiabatic since the time scale is of the order of one ion cyclotron time. Before taking the time derivative, quantities in each panel are normalized using their respective maxima such that the unit of each EOS in figure 10 is the inverse of time. Since we measure the ion temperature along a chord, our $T_{i}$ measurements are insensitive to the direction of magnetic field. We are, therefore, obliged to use total pressure to test the various EOS instead of using $p_{\bot }$ and $p_{\Vert }$ separately. However, using the total pressure for the EOS analysis, we have noted that the parallel CGL EOS is most consistent with our data, which suggests that our plasma consists of mostly parallel proton energy. We would also like to mention that we are not trying to verify that one model or another is correct, but rather noting that one model fits our data best.

6 Simulation results

Because we use minimally invasive diagnostics for the measurement of plasma parameters in an azimuthal plane, we have no way of eliminating the possibility of profile modifications during compression. In order to get information about the profile modifications at other axial locations, we employ simulation techniques. Therefore, the main purpose of simulations is to explore the nature of axial and radial variation of the plasma parameters.

We are employing a three-dimensional resistive MHD code (NIMROD (Sovinec et al. Reference Sovinec, Glasser, Gianakon, Barnes, Nebel, Kruger, Schnack, Plimpton, Tarditi and Chu2004)) to simulate the twisted Taylor states, which possess helical magnetic field lines resembling a rope (called a flux rope). One such helical structure obtained from these simulations is shown in figure 12. The simulations are carried out on a 32 radial $\times$ 192 axial grid with fourth degree polynomials as the basis functions, running with three modes in the azimuthal direction. The boundary conditions are as follows: (i) the grid is specified as rectangular and non-periodic in axial direction, $z$ , (ii) the first wall is assumed to be a perfectly conducting boundary with $B_{\bot }=0$ , (iii) a ‘no-slip’ boundary condition was assumed for velocity, i.e. $v=0$ and (iv) Dirichlet conditions for density. The initial conditions are as follows: (i) an axial velocity, $v_{z}=40~\text{km}~\text{s}^{-1}$ is applied to a compact tori (CT) that is initialized using a Bessel function model to resemble a spheromak with (ii) uniform density of $n=1\times 10^{20}~\text{m}^{-3}$ and (iii) edge poloidal magnetic field, $B=1~\text{T}$ . In our simulations, Ohm’s law does not include the Hall terms. The continuity advance is fully three-dimensional. Thermal conduction is isotropic and is not temperature dependent.

Figure 12. The sequence of formation of a Taylor state: (a) in the beginning, a spheromak is formed at the left end, (b) at $2~\unicode[STIX]{x03BC}\text{s}$ , it tilts and starts relaxing to a helical magnetic flux ropes structure and (c) shows a relaxed, twisted Taylor state at $6.4~\unicode[STIX]{x03BC}\text{s}$ . Due to its inertia, the relaxed structure moves towards the right-hand side and fills almost the full volume.

In figure 12, a sequence of formation of a twisted Taylor state from a spheromak is shown. The colour bar on the top of this figure represents the strength of the background magnetic field. After production, the spheromak relaxes to a twisted structure in a few Alfvén times. A high value of density and a low magnetic field would result in a long Alfvén time, $\unicode[STIX]{x1D70F}_{A}\propto \sqrt{n}/B$ . Therefore in order to reduce the cost of the simulations, we have used a higher value of magnetic field and a smaller value of density than is measured to shorten the simulation relaxation time. The results obtained in this way will be helpful in predicting structural behaviour of our plasma.

Figure 13 shows a magnetic field vector rendering along the axis of the SFC at four different times. The locations of synthetic magnetic diagnostics are chosen to replicate the actual magnetic probes in our experiments. The simulation results are similar to what we observe in our experiments, see figure 7. As we mentioned earlier, there is a considerable difference in the magnitude of magnetic field in comparison to experiments but their overall behaviour is similar to our experimental results. Initially in figure 13, we see one helical lobe of the Taylor state inside the SFC and after some time, a second lobe also enters the SFC.

Figure 13. Simulation rendering of magnetic field vectors along the axis of the SFC at four different times relative to the start of the simulation: (a) $t_{1}=3.27~\unicode[STIX]{x03BC}\text{s}$ corresponds to the time when Taylor state enters the mouth of the SFC, (b) $t_{2}=4.11~\unicode[STIX]{x03BC}\text{s}$ corresponds to when the Taylor state reaches almost midway, (c) $t_{3}=5.39~\unicode[STIX]{x03BC}\text{s}$ when Taylor state reaches the end wall and (d) $t_{4}=6.45~\unicode[STIX]{x03BC}\text{s}$ corresponds to the time when Taylor state gets compressed against the end wall of the SFC. The two solid lines represent the end wall of the SFC and the Taylor state enters from the right-hand side. These vector renderings are similar to what we observe in experiments and shown in figure 7.

In figure 14, plasma density, the magnetic field embedded in the Taylor state and its axial velocity are plotted at the same four time instances corresponding to the vector rendering of magnetic field in the SFC in figure 13. The Taylor state enters the SFC from right-hand side and the red vertical bar indicates the end of the SFC. The simulation results demonstrate an amplification in the magnetic field as the Taylor state compresses against the end wall of the SFC. However, the plasma density is not observed to change much near the end wall during compression. The drop in axial velocity indicates that the Taylor state stagnates after reaching the end wall of the SFC.

Figure 14. Axial variation of the Taylor state (a) plasma density, (b) magnetic field and (c) axial velocity from NIMROD simulations at different times. Vertical red bar in each panel represents the back end of the SFC, therefore 29 cm corresponds to the beginning of the SFC. Different colours in each panel correspond to the axial values at three different time instances (same as in figure 13); (i) the dotted red line corresponds to time $t_{1}=3.27~\unicode[STIX]{x03BC}\text{s}$ , (ii) the dashed blue line to $t_{2}=4.11~\unicode[STIX]{x03BC}\text{s}$ , (iii) the dash-dot cyan line to $t_{3}=5.39~\unicode[STIX]{x03BC}\text{s}$ and (iv) the pink solid line corresponds to $t_{4}=6.45~\unicode[STIX]{x03BC}\text{s}$ . It can be clearly seen that the Taylor state velocity decreases to zero during compression near the back end of the SFC.

7 Discussion

We have identified compressional heating events by constructing PV diagrams in an MHD plasma. During these events, we observe a maximum length contraction of a factor of 30–40 %. The time windows of 192 compression events are used for analysing various equations of state applicable for magnetized plasmas.

The equilibrium of these plasmas is described by MHD but the EOS analysis shows that the MHD EOS does not describe the dynamics of our plasma. It may be because of the fact that our plasma is weakly collisional; $\unicode[STIX]{x1D714}_{ci}\unicode[STIX]{x1D70F}=0.6$ ( $\approxeq 1$ ) for average plasma density of ${\sim}2\times 10^{15}~\text{cm}^{-3}$ , ion temperature of ${\sim}15~\text{eV}$ and magnetic field of ${\sim}1500~\text{G}$ . Due to the weak ion–ion interactions, the effect of magnetic field becomes more dominant on their trajectories.

The perpendicular CGL EOS also does not hold. But surprisingly, the parallel CGL EOS better characterizes the average behaviour of our plasma. Our line-averaged IDS measurements of ion temperature are insensitive to the direction of the local background magnetic field. Nonetheless, we see a difference between the perpendicular and parallel CGL EOS.

We hypothesize about the physical process in the following way. We produce a spheromak using the coaxial magnetized plasma gun. As the spheromak moves away from the gun, it expands and relaxes immediately after formation and the structure unravels towards a twisted Taylor state. In the process of relaxation, the magnetic field associated with the spheromak drops by a factor of 10 or more. Due to the conservation of the first adiabatic invariant, the reduction in the magnetic field causes a concomitant drop in $T_{\bot }$ . By the time the Taylor state enters the stagnation flux conserver located at the other end of the linear device, we suspect that most of the ion energy is in $T_{\Vert }$ . The compression events in the stagnation flux conserver reduce the volume by only 10 %–30 %, which is not enough to lead to a considerable increase in $T_{\bot }$ . The expansion of the solar wind may involve similar physics (Brown & Schaffner Reference Brown and Schaffner2015).

Impurities in the hydrogen plasma, through ionization and excitation states, may affect the $\unicode[STIX]{x1D6FE}=5/3$ assumption to MHD EOS. However, our past studies have shown that the impurity level in SSX is minimal (Chaplin et al. Reference Chaplin, Brown, Cohen, Gray and Cothran2009) and our plasma is optically thin so we do not expect the radiation to contribute to the EOS significantly. In any case, incorporating these effects is beyond the scope of this paper.

In summary, we present a PV analysis of the compression process of a magnetized, relaxed plasma leading to ion heating. A comparison of equations of state applicable to the compression process is carried out which suggests that the parallel CGL equation of state models the average behaviour of our plasma better than other equations of state. Although the magnetized plasma is well described by an MHD equilibrium, the MHD EOS does not agree with experimental observations. Simulation results confirm the presence of a relaxed helical structure and also demonstrate Taylor state stagnation.

While passing through the glass tube, the magnetized plasma can be accelerated using a pulsed magnetic field. The pulsed magnetic field is produced by discharging a capacitor through a pinch coil having a fast quarter cycle rise time. In this way, we wish to accelerate these Taylor states to higher velocity in our future experiments and then compress them to higher density in the SFC. These experiments have already started with one pinch coil. In the near future, we are planning to use four such coils. These coils will be triggered separately and sequentially to accelerate plasma to velocities over $200~\text{km}~\text{s}^{-1}$ , ion temperature over 100 eV and to achieve compressional density over $10^{16}~\text{cm}^{-3}$ in the SFC. Expected higher compression in these acceleration experiments would help in the better understanding of the EOS, as would improved diagnostic coverage.

Acknowledgements

This work is supported by the Accelerating Low-Cost Plasma Heating and Assembly (ALPHA) Program of the Advanced Research Projects Agency Energy (ARPA-E) and Office of Fusion Energy Sciences. We wish to acknowledge S. Palmer and P. Jacobs for their technical support.

References

Awe, T. J., McBride, R. D., Jennings, C. A., Lamppa, D. C., Martin, M. R., Rovang, D. C., Slutz, S. A., Cuneo, M. E., Owen, A. C., Sinars, D. B. et al. 2013 Observations of modified three-dimensional instability structure for imploding $z$ -pinch liners that are premagnetized with an axial field. Phys. Rev. Lett. 111, 235005.CrossRefGoogle ScholarPubMed
Bale, S. D., Kasper, J. C., Howes, G. G., Quataert, E., Salem, C. & Sundkvist, D. 2009 Magnetic fluctuation power near proton temperature anisotropy instability thresholds in the solar wind. Phys. Rev. Lett. 103, 211101.Google Scholar
Brown, M. R. & Schaffner, D. A. 2014 Laboratory sources of turbulent plasma: a unique mhd plasma wind tunnel. Plasma Sources Sci. Technol. 23 (6), 063001.Google Scholar
Brown, M. R. & Schaffner, D. A. 2015 SSX MHD plasma wind tunnel. J. Plasma Phys. 81 (03), 345810302.Google Scholar
Chaplin, V. H., Brown, M. R., Cohen, D. H., Gray, T. & Cothran, C. D. 2009 Spectroscopic measurements of temperature and plasma impurity concentration during magnetic reconnection at the swarthmore spheromak experiment. Phys. Plasmas 16 (4), 042505.CrossRefGoogle Scholar
Chew, G. F., Goldberger, M. L. & Low, F. E. 1956 The Boltzmann equation and the one-fluid hydromagnetic equations in the absence of particle collisions. Proc. R. Soc. Lond. A 236 (1204), 112118.Google Scholar
Cothran, C. D., Brown, M. R., Gray, T., Schaffer, M. J. & Marklin, G. 2009 Observation of a helical self-organized state in a compact toroidal plasma. Phys. Rev. Lett. 103, 215002.Google Scholar
Cothran, C. D., Fung, J., Brown, M. R. & Schaffer, M. J. 2006 Fast high resolution echelle spectroscopy of a laboratory plasma. Rev. Sci. Instrum. 77 (6), 063504.Google Scholar
Degnan, J. H., Alme, M. L., Austin, B. S., Beason, J. D., Coffey, S. K., Gale, D. G., Graham, J. D., Havranek, J. J., Hussey, T. W., Kiuttu, G. F. et al. 1999 Compression of plasma to megabar range using imploding liner. Phys. Rev. Lett. 82, 26812684.CrossRefGoogle Scholar
Geddes, C. G. R., Kornack, T. W. & Brown, M. R. 1998 Scaling studies of spheromak formation and equilibrium. Phys. Plasmas 5 (4), 10271034.Google Scholar
Gomez, M. R., Slutz, S. A., Sefkow, A. B., Sinars, D. B., Hahn, K. D., Hansen, S. B., Harding, E. C., Knapp, P. F., Schmit, P. F., Jennings, C. A. et al. 2014 Experimental demonstration of fusion-relevant conditions in magnetized liner inertial fusion. Phys. Rev. Lett. 113, 155003.Google Scholar
Gray, T., Brown, M. R. & Dandurand, D. 2013 Observation of a relaxed plasma state in a quasi-infinite cylinder. Phys. Rev. Lett. 110 (8), 085002.Google Scholar
Hammer, J. H., Eddleman, J. L., Hartman, C. W., McLean, H. S. & Molvik, A. W. 1991 Experimental demonstration of compact torus compression and acceleration. Phys. Fluids B 3 (8), 22362240.Google Scholar
Hammer, J. H., Hartman, C. W., Eddleman, J. L. & McLean, H. S. 1988 Experimental demonstration of acceleration and focusing of magnetically confined plasma rings. Phys. Rev. Lett. 61, 28432846.Google Scholar
Hurricane, O. A., Callahan, D. A., Casey, D. T., Celliers, P. M., Cerjan, C., Dewald, E. L., Dittrich, T. R., Doppner, T., Hinkel, D. E., Berzak Hopkins, L. F. et al. 2014 Fuel gain exceeding unity in an inertially confined fusion implosion. Nature 506 (7488), 343348.Google Scholar
Kasper, J. C., Lazarus, A. J. & Gary, S. P. 2002 Wind/swe observations of firehose constraint on solar wind proton temperature anisotropy. Geophys. Res. Lett. 29 (17), 20–1–20–4, 1839.Google Scholar
Kasper, J. C., Lazarus, A. J., Gary, S. P. & Szabo, A. 2003 Solar wind temperature anisotropies. AIP Conf. Proc. 679 (1), 538541.Google Scholar
Kaur, M., Barbano, L. J., Suen-Lewis, E. M., Shrock, J. E., Light, A. D., Brown, M. R. & Schaffner, D. A. 2018 Measuring the equations of state in a relaxed magnetohydrodynamic plasma. Phys. Rev. E 97, 011202.Google Scholar
Lindemuth, I. & Kirkpatrick, R. 1983 Parameter space for magnetized fuel targets in inertial confinement fusion. Nucl. Fusion 23 (3), 263.Google Scholar
Lindemuth, I. R. 2015 The ignition design space of magnetized target fusion. Phys. Plasmas 22 (12), 122712.Google Scholar
Lindemuth, I. R. 2017 An extended study of the ignition design space of magnetized target fusion. Phys. Plasmas 24 (5), 055602.Google Scholar
Molvik, A. W., Eddleman, J. L., Hammer, J. H., Hartman, C. W. & McLean, H. S. 1991 Quasistatic compression of a compact torus. Phys. Rev. Lett. 66, 165168.Google Scholar
Park, H.-S., Hurricane, O. A., Callahan, D. A., Casey, D. T., Dewald, E. L., Dittrich, T. R., Döppner, T., Hinkel, D. E., Berzak Hopkins, L. F., Le Pape, S. et al. 2014 High-adiabat high-foot inertial confinement fusion implosion experiments on the national ignition facility. Phys. Rev. Lett. 112, 055001.Google Scholar
Schaffner, D. A., Lukin, V. S., Wan, A. & Brown, M. R. 2014 Turbulence analysis of an experimental flux-rope plasma. Plasma Phys. Control. Fusion 56 (6), 064003.Google Scholar
Slough, J., Votroubek, G. & Pihl, C. 2011 Creation of high-temperature plasma through merging and compression of supersonic field reversed configuration plasmoids. Nucl. Fusion 51, 053008.CrossRefGoogle Scholar
Slutz, S. A. & Vesey, R. A. 2012 High-gain magnetized inertial fusion. Phys. Rev. Lett. 108, 025003.Google Scholar
Sovinec, C., Glasser, A., Gianakon, T., Barnes, D., Nebel, R., Kruger, S., Schnack, D., Plimpton, S., Tarditi, A. & Chu, M. 2004 Nonlinear magnetohydrodynamics simulation using high-order finite elements. J. Comput. Phys. 195 (1), 355386.Google Scholar
Taylor, J. B. 1985 Relaxation and magnetic reconnection in laboratory plasmas. Plasma Phys. Control. Fusion 27 (12A), 1439.CrossRefGoogle Scholar
Taylor, J. B. 1986 Relaxation and magnetic reconnection in plasmas. Rev. Mod. Phys. 58 (3), 741.Google Scholar
Thomas, J., Hwang, D., Horton, R., Rogers, J. & Raman, R. 1993 A simple fast pulse gas valve using a dynamic pressure differential as the primary closing mechanism. Rev. Sci. Instrum. 64 (6), 14101413.Google Scholar
Torrence, C. & Compo, G. P. 1998 A practical guide to wavelet analysis. Bull. Am. Meteorol. Soc. 79 (1), 6178.Google Scholar
Votroubek, G., Slough, J., Andreason, S. & Pihl, C. 2008 Formation of a stable field reversed configuration through merging. J. Fusion Energy 27 (1), 123127.Google Scholar
Woltjer, L. 1958 A theorem on force-free magnetic fields. Proc. Natl Acad. Sci. USA 44 (6), 489491.CrossRefGoogle ScholarPubMed
Figure 0

Figure 1. A schematic of the experimental set-up. A glass tube has been added in between the gun and the stagnation flux conserver (SFC) and is covered with a copper flux conserving shell. A Permendur magnet rod is installed at the centre of the inner electrode shell. All the three principal plasma diagnostics are located in the SFC at the location of the circle. $T_{i}$ is measured using ion Doppler spectroscopy along the vertical chord and $n$ is measured using HeNe laser interferometry along a horizontal chord. The long ${\dot{B}}$ probe array is aligned along the axis of the SFC. The red lines on the magnetic probe array represent the locations of the ${\dot{B}}$ probes.

Figure 1

Figure 2. A cross-sectional view of the set-up along with diagnostics. In ion Doppler spectroscopy, $C_{III}$ line (229.687 nm) is dispersed using an echelle grating and recorded at twenty-fifth order. In laser interferometry, the interference output is passed through a Wollaston prism which generates two outputs $90^{\circ }$ out of phase with each other. The circle indicates the position of the ${\dot{B}}$ probe array, slightly off-centred.

Figure 2

Figure 3. A typical lineshape obtained from the ion Doppler spectroscopy at $60~\unicode[STIX]{x03BC}\text{s}$ using 16 channels on PMT array. The cross-marks in the black colour correspond to the photocurrent and the red colour bars represent their corresponding error bars. The blue line represents the Gaussian fit to the IDS data and the ion temperature obtained from the half-width-full-maxima of this Gaussian lineshape is ${\sim}12~\text{eV}$.

Figure 3

Figure 4. A typical envelope obtained from the interferometer detectors to be used in calibration for determining the electron density.

Figure 4

Figure 5. Velocity of the Taylor state using time of flight method from three ${\dot{B}}$ probes. The bulk Taylor state velocity is ${\sim}37~\text{km}~\text{s}^{-1}$ whereas its leading edge moves at ${\sim}60~\text{km}~\text{s}^{-1}$.

Figure 5

Figure 6. A typical time trace of (a) plasma density, (b) ion temperature and (c) magnetic field measured inside the stagnation flux conserver. The error bars for $T_{i}$ are indicated by the vertical bars at each time value whereas the uncertainty in $n$ and $B$ is ${<}10\,\%$. The 10 % uncertainty accounts for the errors due to a high frequency buzz present in the interferometer detector signals for density (also can be seen in figure 4) and due to the numerical integration in the magnetic field. Taylor state enters the SFC at ${\approx}40~\unicode[STIX]{x03BC}\text{s}$ (indicated by the blue bar) and then compresses against the closed end of the SFC accompanied by a rise in $T_{i}$ at $40$, $55$ and $75~\unicode[STIX]{x03BC}\text{s}$ (indicated by the pink bar).

Figure 6

Figure 7. A typical helical structure from the ${\dot{B}}$ probe array along the axis of the SFC at different time instances (for the same shot as figure 6): (a) $t_{1}=43.68~\unicode[STIX]{x03BC}\text{s}$, (b) $t_{2}=51.48~\unicode[STIX]{x03BC}\text{s}$, (c) $t_{3}=60.43~\unicode[STIX]{x03BC}\text{s}$ and (d) $t_{4}=74.97~\unicode[STIX]{x03BC}\text{s}$. The two solid black lines represent the back end of the flux conserver. The twisted Taylor state enters the SFC from right hand side and gets compressed against the back end of the SFC.

Figure 7

Figure 8. The image of the wavelet analysis at a particular time instance for the same shot as figure 6. The colour bar on the right-hand side tells the power in a particular wavenumber. The white dot represents the centroid of the most dominant wavenumber and the hyperbola-like white curve represents the cone of influence below which the wavenumber values are unreliable.

Figure 8

Figure 9. (a) A time trace of effective length (for the same shot as figure 6) of the Taylor state, (b) an associated increase in pressure and (c) a trajectory of the thermodynamic state of the object in a PV diagram for the compression process. Uncertainty in the thermal pressure is $\approxeq 15\,\%$ and is determined by propagating the errors in density and ion temperature. The uncertainty in the length of the Taylor state is ${\approx}10\,\%$ and is determined using the innermost contour of the wavelet analysis (see figure 8). Note that as the volume of the Taylor state decreases the pressure shifts to higher isotherms.

Figure 9

Figure 10. Statistical variation of three equations of state for 192 compression events (length contraction ranges from 10–30 %) are shown by light blue lines for: (a) the magnetohydrodynamic equation of state for three-dimensional compression ($\unicode[STIX]{x1D6FE}=5/3$), (b) perpendicular and (c) parallel CGL equations of state as a function of time. The dark blue band in each panel shows the standard error of the mean. Note that the MHD equation of state (a), and the perpendicular version of the CGL EOS (b) have non-zero time derivative. However, the parallel version of the CGL EOS (c) has nearly zero time derivative for most the compression time. Reprinted with permission from Kaur et al. (2018). Copyright 2017 The American Physical Society.

Figure 10

Figure 11. Statistical time variation of three equations of state for 192 compression events is shown by the light blue lines for: (a) the MHD EOS for three-dimensional compression, (b) perpendicular and (c) parallel CGL EOS. The dark blue band in each panel shows the standard error of the mean, while the red colour bars represent the error bars in each individual event. It is clear that the error bars for the MHD EOS (a), and the perpendicular version of the CGL EOS (b) are not consistent with the zero axis. However, the parallel version of the CGL EOS (c) error bar is evenly distributed around zero axis.

Figure 11

Figure 12. The sequence of formation of a Taylor state: (a) in the beginning, a spheromak is formed at the left end, (b) at $2~\unicode[STIX]{x03BC}\text{s}$, it tilts and starts relaxing to a helical magnetic flux ropes structure and (c) shows a relaxed, twisted Taylor state at $6.4~\unicode[STIX]{x03BC}\text{s}$. Due to its inertia, the relaxed structure moves towards the right-hand side and fills almost the full volume.

Figure 12

Figure 13. Simulation rendering of magnetic field vectors along the axis of the SFC at four different times relative to the start of the simulation: (a) $t_{1}=3.27~\unicode[STIX]{x03BC}\text{s}$ corresponds to the time when Taylor state enters the mouth of the SFC, (b) $t_{2}=4.11~\unicode[STIX]{x03BC}\text{s}$ corresponds to when the Taylor state reaches almost midway, (c) $t_{3}=5.39~\unicode[STIX]{x03BC}\text{s}$ when Taylor state reaches the end wall and (d) $t_{4}=6.45~\unicode[STIX]{x03BC}\text{s}$ corresponds to the time when Taylor state gets compressed against the end wall of the SFC. The two solid lines represent the end wall of the SFC and the Taylor state enters from the right-hand side. These vector renderings are similar to what we observe in experiments and shown in figure 7.

Figure 13

Figure 14. Axial variation of the Taylor state (a) plasma density, (b) magnetic field and (c) axial velocity from NIMROD simulations at different times. Vertical red bar in each panel represents the back end of the SFC, therefore 29 cm corresponds to the beginning of the SFC. Different colours in each panel correspond to the axial values at three different time instances (same as in figure 13); (i) the dotted red line corresponds to time $t_{1}=3.27~\unicode[STIX]{x03BC}\text{s}$, (ii) the dashed blue line to $t_{2}=4.11~\unicode[STIX]{x03BC}\text{s}$, (iii) the dash-dot cyan line to $t_{3}=5.39~\unicode[STIX]{x03BC}\text{s}$ and (iv) the pink solid line corresponds to $t_{4}=6.45~\unicode[STIX]{x03BC}\text{s}$. It can be clearly seen that the Taylor state velocity decreases to zero during compression near the back end of the SFC.