Hostname: page-component-78c5997874-fbnjt Total loading time: 0 Render date: 2024-11-04T17:54:02.206Z Has data issue: false hasContentIssue false

The use of GlideScope for biopsies of the tongue base

Published online by Cambridge University Press:  07 December 2012

P K Shenoy*
Affiliation:
Department of ENT, Campbellton Regional Hospital, Canada
M Aldea
Affiliation:
Department of Anaesthesia, Campbellton Regional Hospital, Canada
*
Address for correspondence: Dr P K Shenoy, Ear Nose Throat Department, Campbellton Regional Hospital, 189 Lily Lake Rd, Campbellton, New Brunswick E3N 3H3, Canada Fax: 001 506 6847148 E-mail: [email protected]

Abstract

Objective:

To report a case where GlideScope® is used for the biopsy of the tongue base.

Background:

GlideScopes are used by anaesthetists for difficult intubations.

Case report:

This paper reports a case where a GlideScope was used for biopsy of the tongue base. A review of the literature indicated that this was the first time a GlideScope had been utilised for this purpose.

Conclusion:

It is suggested that this is a safe and ideal technique for biopsy of the tongue base, and GlideScopes could be used more frequently for this purpose in the future.

Type
Clinical Records
Copyright
Copyright © JLO (1984) Limited 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1Qasim, Z. Towards evidence-based emergency medicine: best BETs from the Manchester Royal Infirmary. BET 2. GlideScope in the emergency department. Emerg Med J 2011;28:165–6Google Scholar
2Niforopoulou, P, Pantazopoulos, I, Dimestiha, T, Koudouna, E, Xanthos, T. Video-laryngoscopes in the adult airway management: a topical review of the literature. Acta Anaesthesiol Scand 2010;54:1050–61CrossRefGoogle ScholarPubMed
3Benjamin, FJ, Boon, D, French, RA. An evaluation of the GlideScope, a new video laryngoscope for difficult airways: a manikin study. Eur J Anaesthesiol 2006;23:517–21CrossRefGoogle ScholarPubMed
4Morris, LM, Wax, MK, Weber, SM. Removal of hypopharyngeal foreign bodies with the GlideScope video laryngoscope. Otolaryngol Head Neck Surg 2009;141:416–17CrossRefGoogle ScholarPubMed
5Civelek, S, Cakir, B, Emre, I, Ozcelik, M, Turgut, S. GlideScope video laryngoscope-assisted tongue base radiofrequency for the treatment of obstructive sleep apnoea: pilot study. J Otolaryngol Head Neck Surg 2010;39:329–34Google ScholarPubMed