Hostname: page-component-586b7cd67f-dsjbd Total loading time: 0 Render date: 2024-11-27T23:57:00.116Z Has data issue: false hasContentIssue false

Iatrogenic tracheal flap mimicking tracheal stenosis with resultant stridor

Published online by Cambridge University Press:  14 May 2012

K L Tan*
Affiliation:
Department of Otorhinolaryngology, Universiti Malaya Medical Centre, Kuala Lumpur, Malaysia
A W Chong
Affiliation:
Department of Otorhinolaryngology, Universiti Malaya Medical Centre, Kuala Lumpur, Malaysia
M A Amin
Affiliation:
Department of Otorhinolaryngology, Universiti Malaya Medical Centre, Kuala Lumpur, Malaysia
R Raman
Affiliation:
Department of Otorhinolaryngology, Universiti Malaya Medical Centre, Kuala Lumpur, Malaysia
*
Address for correspondence: Dr K L Tan, Department of Otorhinolaryngology, Universiti Malaya Medical Centre, Lembah Pantai, 59100, Kuala Lumpur, Malaysia E-mail: [email protected]

Abstract

Objective:

To illustrate a case of an iatrogenic mucosal tear in the trachea which caused a one-way valve effect, obstructing the airway and manifesting as post-extubation stridor.

Case report:

We report a case of iatrogenic tracheal mucosal tear secondary to violent movement during intubation. The patient presented with post-extubation stridor that worsened over three days. Initial evidence suggested tracheal stenosis. Computed tomography scans revealed a mucosal tear at the level of the seventh cervical to second thoracic vertebrae. The tear was caused by forceful inflow of air as breathing became more and more difficult, resulting in a false tract. A tracheostomy changed the direction of airflow, bypassing the tear. The inflated tracheostomy tube cuff acted as a stent to keep the flap in place as healing occurred.

Conclusion:

Iatrogenic laryngotracheal injuries are common, especially when endotracheal intubation is performed under unfavourable emergency conditions. A tracheal mucosal tear is a rare entity which is almost always undiagnosed. However, a tracheal mucosal flap may be suspected when changes in patient position alter the nature and severity of the resultant stridor and/or respiratory distress. In such cases, an inflated tracheostomy tube cuff should be kept in place for an adequate period, to act as a stent and help keep the flap in place while healing occurs.

Type
Clinical Records
Copyright
Copyright © JLO (1984) Limited 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1Zias, N, Chroneou, A, Tabba, MK, Gonzalez, AV, Gray, AW, Lamb, CR. Post tracheostomy and post intubation tracheal stenosis: report of 31 cases and review of the literature. BMC Pulmonary Medicine 2008;8:18CrossRefGoogle ScholarPubMed
2Cardillo, G, Carbone, L, Carleo, F, Batzella, S, Jacono, RD, Lucantoni, G. Tracheal lacerations after endotracheal intubation: a proposed morphological classification to guide non-surgical treatment. Eur J Cardiothorac Surg 2010;37:581–7CrossRefGoogle ScholarPubMed
3Beebe, DS. Complications of tracheal intubation. Seminars in Anesthesia, Perioperative Medicine and Pain 2001;20:166–72CrossRefGoogle Scholar
4Miñambres, E, Burón, J, Ballesteros, MA. Tracheal rupture after endotracheal intubation: a literature systematic review. Eur J Cardiothorac Surg 2009;35:1056–62CrossRefGoogle ScholarPubMed
5Chen, EH, Logman, ZM, Glass, PSA, Bilfinger, TV. A case of tracheal injury after emergent endotracheal intubation: a review of the literature and casualities. Anesth Analg 2001;93:1270–1CrossRefGoogle Scholar
6Fan, CM, Ko, PC, Tsai, KC, Chiang, WC, Chang, YC, Chen, WJ et al. Tracheal rupture complicating emergent endotracheal intubation. Am J Emerg Med 2004;22:289–93CrossRefGoogle ScholarPubMed
7Chang, YL, Chien, NC, Hsu, SY, Lai, YY. Tracheal rupture after emergent endotracheal intubation. Tzu Chi Med J 2008;20:227–31CrossRefGoogle Scholar