Hostname: page-component-78c5997874-m6dg7 Total loading time: 0 Render date: 2024-11-07T23:09:49.400Z Has data issue: false hasContentIssue false

Subdural haematoma as a rare complication of cochlear implantation: case report and literature review

Published online by Cambridge University Press:  09 July 2013

M S Gürbüz*
Affiliation:
Department of Neurosurgery, Haydarpaşa Numune Training and Research Hospital, Üsküdar, İstanbul, Turkey
M Orakdöğen
Affiliation:
Department of Neurosurgery, Haydarpaşa Numune Training and Research Hospital, Üsküdar, İstanbul, Turkey
M Z Berkman
Affiliation:
Department of Neurosurgery, Haydarpaşa Numune Training and Research Hospital, Üsküdar, İstanbul, Turkey
M O Yüksel
Affiliation:
Department of Neurosurgery, Haydarpaşa Numune Training and Research Hospital, Üsküdar, İstanbul, Turkey
*
Address for correspondence: Dr Mehmet Sabri Gürbüz, Tıbbiye cad 40, 34668 Üsküdar, İstanbul, Turkey Fax: +90 2163360565 E-mail: [email protected]

Abstract

Objective:

To report a case of subdural haematoma occurring as an extremely rare and life-threatening complication of cochlear implantation, and to explore the causative association between intracranial haemorrhage and cochlear implantation surgical techniques. This association has not previously been reviewed in depth.

Case report:

A three-year-old boy was diagnosed with a large subdural haematoma, one week after cochlear implantation. After emergency evacuation of the haematoma, the patient made an excellent recovery and was discharged from hospital without any neurological deficit.

Results:

Mechanisms of injury are discussed and the literature reviewed, focusing on the possible causes of intracranial haemorrhage identified after cochlear implantation. Notably, bone drilling had been used in all reported cases, and the probable causative injury had always occurred after such drilling.

Conclusion:

The issue of bone drilling during cochlear implantation is raised, and alternative methods of implant housing suggested, in order to avoid intracranial haemorrhage.

Type
Clinical Records
Copyright
Copyright © JLO (1984) Limited 2013 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1Lima Júnior, LR, Rodrigues Júnior Fde, A, Calhau, CM, Calhau, AC, Palhano, CT.Postoperative complications in implanted patients in the Cochlear Implant Program of Rio Grande do Norte-Brazil. Braz J Otorhinolaryngol 2010;76:517–21CrossRefGoogle Scholar
2Loundon, N, Blanchard, M, Roger, G, Denoyelle, F, Garabedian, EN.Medical and surgical complications in pediatric cochlear implantation. Arch Otolaryngol Head Neck Surg 2010;136:1215CrossRefGoogle ScholarPubMed
3Stamatiou, GA, Kyrodimos, E, Sismanis, A.Complications of cochlear implantation in adults. Ann Otol Rhinol Laryngol 2011;120:428–32CrossRefGoogle ScholarPubMed
4Sunkaraneni, VS, Banerjee, A, Gray, RF.Subdural haematoma: a complication of cochlear implantation. J Laryngol Otol 2004;118:980–2CrossRefGoogle ScholarPubMed
5Barraclough, JP, Pearman, K, Solanki, G.Extradural haematoma presenting as a contralateral sixth nerve palsy after cochlear implantation. Cochlear Implants Int 2009;10:112–18CrossRefGoogle ScholarPubMed
6Benson, AG.Delayed onset intracranial hemorrhage: a rare complication of a cochlear implant. Otolaryngol Head Neck Surg 2010;142:917–18CrossRefGoogle ScholarPubMed
7Dodson, KM, Maiberger, PG, Sismanis, A.Intracranial complications of cochlear implantation. Otol Neurotol 2007;28:459–62CrossRefGoogle ScholarPubMed
8Hagr, A, Bance, M.Intracranial hemorrhage: a rare complication of cochlear implant. Saudi Journal of Oto-Rhino-Laryngology and Head and Neck Surg 2007;9:27–9Google Scholar
9Gosepath, J, Maurer, J, Mann, WJ.Epidural hematoma after cochlear implantation in a 2.5-year-old boy. Otol Neurotol 2005;26:202–4CrossRefGoogle Scholar
10Venail, F, Sicard, M, Piron, JP, Levi, A, Artieres, F, Uziel, A et al. Reliability and complications of 500 consecutive cochlear implantations. Arch Otolaryngol Head Neck Surg 2008;134:1276–81CrossRefGoogle ScholarPubMed
11Boscolo-Rizzo, P, Muzzi, E, Barillari, MR, Trabalzini, F.Non-sutured fixation of the internal receiver-stimulator in cochlear implantation. Eur Arch Otorhinolaryngol 2011;268:961–5CrossRefGoogle ScholarPubMed
12Loh, C, Jiang, D, Dezso, A, Fitzgerald O'Connor, A.Non-sutured fixation of cochlear implants using minimally-invasive approach. Clin Otolaryngol 2008;33:259–61CrossRefGoogle ScholarPubMed
13Molony, TB, Giles, JE, Thompson, TL, Motamedi, KK.Device fixation in cochlear implantation: is bone anchoring necessary? Laryngoscope 2010;120:1837–9CrossRefGoogle ScholarPubMed
14Adunka, OF, Buchman, CA.Cochlear implant fixation in children using periosteal sutures. Otol Neurotol 2007;28:768–70CrossRefGoogle ScholarPubMed
15Alexander, NS, Caron, E, Wooley, AL.Fixation methods in pediatric cochlear implants: retrospective review of an evolution of 3 techniques. Otolaryngol Head Neck Surg 2011;144:427–30CrossRefGoogle ScholarPubMed