1. Introduction
1.1. Background
The release of particle-laden fluid into the environment occurs in many settings, including both subaerial and subaqueous explosive volcanic eruptions (Head & Wilson Reference Head III and Wilson2003; Woods Reference Woods2010; Newland, Mingotti & Woods Reference Newland, Mingotti and Woods2022; Rowell et al. Reference Rowell, Jellinek, Hajimirza and Aubry2022) and tailings discharge from vessels during deep-sea mining (Mingotti & Woods Reference Mingotti and Woods2020). The conditions of the ambient environment, such as density stratification and the presence of local crossflows, play a critical role in controlling the dynamics of these multiphase flows. Such conditions will have a significant effect on the dispersal distance of particles and the final location of the fluid in the flow, parameters which are both considered environmentally and economically important.
Geophysical flows are often more dense than the ambient fluid they interact with, due to the presence of dissolved or entrained material, and if the flow issues from a localised source and the buoyancy of the flow opposes the momentum of the flow, it will behave as a turbulent fountain (Hunt & Burridge Reference Hunt and Burridge2015). Following the classical work on single-phase turbulent fountains (Morton, Taylor & Turner Reference Morton, Taylor and Turner1956; Turner Reference Turner1966), there have been numerous experimental studies (Turner Reference Turner1973; Baines, Turner & Campbell Reference Baines, Turner and Campbell1990; Zhang & Baddour Reference Zhang and Baddour1998; Kaye & Hunt Reference Kaye and Hunt2006; Williamson et al. Reference Williamson, Srinarayana, Armfield, Mcbain and Lin2008; Burridge & Hunt Reference Burridge and Hunt2012) that describe the rise and subsequent collapse of these flows. These observations are further complemented by a suite of theoretical models (McDougall Reference McDougall1981; Bloomfield & Kerr Reference Bloomfield and Kerr2000; Mehaddi et al. Reference Mehaddi, Vaux, Candelier and Vauquelin2015) that build on the entrainment assumption of Morton et al. (Reference Morton, Taylor and Turner1956), and find that for a turbulent fountain the entrainment coefficient $\alpha = 0.085 \pm 0.01$.
Mingotti & Woods (Reference Mingotti and Woods2016) carried out a detailed experimental study into particle-laden turbulent fountains in a homogeneous environment and showed that the dynamics of the two-phase flow is dependent on the ratio of the fall speed of the entrained particles, $v_s$, to the characteristic speed of the fountain, $u_f$,
where
is a function of the source momentum flux, $M_0$, and the magnitude of the source buoyancy flux, $|B_0|$. The authors demonstrated that when $U\ll 1$, a particle-laden fountain behaves essentially as a classical single-phase fountain. However, for $U\sim 1$, the particles separate from the flow during the fountains ascent and settle to the floor, leaving the remaining fountain fluid positively buoyant which then rises as a plume. Using similar experimental techniques, Carazzo, Kaminski & Tait (Reference Carazzo, Kaminski and Tait2015) and Newland et al. (Reference Newland, Mingotti and Woods2022) investigated the effect of particle-sedimentation in turbulent fountains on the dynamics of volcanic eruption columns.
In many natural environments, for example the atmosphere or ocean, turbulent flows may interact with lateral crossflows, with magnitude $u_a$, that occur in the ambient fluid. There have been numerous investigations into the complex interaction between negatively buoyant single-phase fountains with a uniform crossflow (Taherian & Mohammadian Reference Taherian and Mohammadian2021). Early studies, with a focus on the dilution of brine when discharged into estuaries (Anderson, Parker & Benedict Reference Anderson, Parker and Benedict1973; Pincince & List Reference Pincince and List1973), presented extensive experimental data on jets that were both perpendicular and at an angle to a crossflow. Integral models were used to estimate the centreline location and average dilution of the flow, however Anderson et al. (Reference Anderson, Parker and Benedict1973) concluded that the models were only able to predict trends in the data rather than exact dilution profiles. Subsequently, by developing a model of forced plumes in a crossflow (Chu & Goldberg Reference Chu and Goldberg1974), Chu (Reference Chu1975) introduced a mechanistic model for the motion and dilution of dense jets in a crossflow. This model, based on the assumption that the horizontal velocity of the fountain, $u$, quickly adjusts to the speed of the local crossflow, produced centreline trajectories that showed good agreement with the experimental data presented. Further detailed experimental studies (Roberts & Toms Reference Roberts and Toms1987; Gungor & Roberts Reference Gungor and Roberts2009; Choi, Lai & Lee Reference Choi, Lai and Lee2016; Ben Meftah et al. Reference Ben Meftah, Malcangio, De Serio and Mossa2018) qualitatively and quantitatively summarised the general characteristics of single-phase fountains in a crossflow as a function of the dimensionless crossflow Froude number, $Fr_a = ({\rm \pi} / 4)^ {1/4} u_a / u_f$. Ansong, Anderson-Frey & Sutherland (Reference Ansong, Anderson-Frey and Sutherland2011) extended the Lagrangian theory for fountains in a stationary fluid to predict the centreline and radius of a fountain in a one- and two-layer crossflow. Their model assumes that the momentum flux at the source is predominantly vertical and therefore is only valid for sufficiently small crossflows.
It should also be noted that there is a significant body of literature on both single-phase and particle-laden plumes in a crossflow, initiated by the foundational work of Hoult, Fay & Forney (Reference Hoult, Fay and Forney1969), Hewett, Fay & Hoult (Reference Hewett, Fay and Hoult1971) and Slawson & Csanady (Reference Slawson and Csanady1967), in which the authors developed models that trace the motion of the centreline of single-phase flows. Comprehensive studies into the entrainment of ambient fluid into such flows have since been carried out with a specific focus on volcanic plumes (Degruyter & Bonadonna Reference Degruyter and Bonadonna2013; Woodhouse et al. Reference Woodhouse, Hogg, Phillips and Sparks2013; Aubry et al. Reference Aubry, Jellinek, Carazzo, Gallo, Hatcher and Dunning2017; Michaud-Dubuy, Carazzo & Kaminski Reference Michaud-Dubuy, Carazzo and Kaminski2020). James, Mingotti & Woods (Reference James, Mingotti and Woods2022) investigated the effect of particle sedimentation on the structure of particle-laden plumes in a crossflow and Mingotti & Woods (Reference Mingotti and Woods2022) extended this study by exploring the effect of varying the buoyancy of the interstitial fluid on the dynamics of such flows.
There has been significantly less attention paid to particle-laden fountains in a uniform crossflow. Fan, Xu & Wang (Reference Fan, Xu and Wang2010) and Park & Park (Reference Park and Park2021) measured the detailed structure and particle concentration in particle-laden jets, with the latter focusing on the influence of counter-rotating vortex pairs on particle dispersion in the flow. However, they did not compare the transport of the particles with the predictions of the Chu-type models of jets in a cross-flow in order to predict particle transport and deposition distances. Here we develop a series of new experiments to compare the predictions of these single-phase models with new experimental data. Figure 1 summarises the major works in this field.
1.2. Dimensionless scalings
Throughout this paper, the fountains we consider have a source Froude number, $Fr \gg 1$, where
and $u_0$, $r_0$ and $g'_0$ are the source speed, radius and buoyancy, respectively. This condition ensures that the momentum carries the flow vertically a greater distance than the scale of the source and, hence, the dynamics of the fountain are strongly influenced by turbulent entrainment (Morton et al. Reference Morton, Taylor and Turner1956; Burridge & Hunt Reference Burridge and Hunt2012; Hunt & Burridge Reference Hunt and Burridge2015), such that the top height of the fountain scales as
In the case that a forced fountain is rising through an ambient crossflow, there is an additional length scale to consider (Hoult et al. Reference Hoult, Fay and Forney1969; Hoult & Weil Reference Hoult and Weil1972; Roberts & Toms Reference Roberts and Toms1987; Gungor & Roberts Reference Gungor and Roberts2009; Devenish et al. Reference Devenish, Rooney, Webster and Thomson2010b), the jet adjustment length, $h_m$, that describes the height over which the speed of the fountain decreases to a value that is comparable to the speed of the crossflow:
The ratio of the buoyancy-controlled length scale, $h_f$, to the jet adjustment length scale, $h_m$, provides a measure of the effect of the crossflow on the dynamics of a fountain. We define this ratio as
When $P<1$ the speed of the crossflow is small in comparison with characteristic fountain speed, and therefore the height of the fountain is limited by the source momentum and buoyancy fluxes and the ascent of the fountain is close to vertical. As the crossflow speed increases ($P>1$), the fountain is bent over and the jet adjustment length decreases as $u_a^{-1}$ (1.5) until $h_m$ becomes the limiting length scale of the height of the fountain.
To assess the effect of particle size on the dynamics of the particle fountains in a crossflow, we adopt the approach of Mingotti & Woods (Reference Mingotti and Woods2016) and use the dimensionless fall speed of the particles, $U$ (1.1). Similar to the dynamics of particle fountains in a stagnant homogeneous environment, when the crossflow speed is small in comparison with fountain speed ($P<1$) we expect that for small particles ($U\ll 1$) the fountain will behave essentially as a single phase and for larger particles ($U>1$), particle separation will dominate the dynamics of the flow. However, as the crossflow speed increases ($P>1$) we anticipate that the critical value of $U$ at which particle separation becomes important will be a function of the non-dimensional crossflow speed, $P$ (figure 2). In this paper, we explore the effect of both $U$ and $P$ on the dynamics of these multiphase flows.
In § 2 of this study we describe the experimental set-up and image processing used throughout. We then present a set of reference experiments showing single-phase saline fountains injected from a moving source into a reservoir of fresh water and compare the data with the models developed in Chu (Reference Chu1975) and Ansong et al. (Reference Ansong, Anderson-Frey and Sutherland2011). Following this, we describe a series of experiments in which we form particle-laden fountains with neutrally buoyant interstitial fluid in a uniform crossflow and systematically vary the particle size and hence particle settling speed, $v_s$, and the crossflow speed, $u_a$. From these experiments, we identify three distinct regimes as a function of the dimensionless fall speed of the particles, $U$ and investigate the effect of varying the crossflow speed on the point of transition between each regime. We present quantitative data on the fall speed of the particles and measure the average dispersal distance of the particles and compare these data with the model predictions of Chu (Reference Chu1975) to identify when particle separation effects become dominant. In § 5, we summarise the dynamics of these flows using a regime diagram and we consider the implications of this study for submarine volcanic eruptions.
2. Experimental set-up
To form small-scale negatively buoyant fountains in a uniform crossflow, we adopt an experimental approach used in earlier studies (Hoult et al. Reference Hoult, Fay and Forney1969; Chu & Goldberg Reference Chu and Goldberg1974; James et al. Reference James, Mingotti and Woods2022) and move a source at a constant speed through a static ambient environment; we expect this to be equivalent to a static source issuing a fluid into a uniformly flowing ambient. The experimental system consists of a large Perspex tank with length and width dimensions of $300\,{\rm cm}\times 60\,{\rm cm}$ (figure 3) filled with fresh or saline water to a depth of 50 cm. Fitted to the top of the tank is a track, along which a motorised trolley moves at constant speed. The saline solution or particle–fluid suspension that forms the fountain is supplied through a nozzle, with an inner diameter of 5 mm, located at the base of the trolley. The nozzle has an outer diameter of 2 cm and height of 5 cm (aspect ratio, $AR = 2.5$). Given the low $AR$ of the nozzle, we do not expect there to be significant vortex shedding as a result of the flow around the nozzle and therefore do not expect that the dynamics of our fountain to be affected by the wake that forms behind the nozzle (Sumner, Heseltine & Dansereau Reference Sumner, Heseltine and Dansereau2004). The temperature of the injected and ambient fluid is measured and the variation between them is determined to be less than 0.5 $^\circ$C for each experiment. The arms of the trolley are sufficiently thin such that any wake produced by the trolley as it traverses along the tank does not have a measurable effect on the dynamics of the fountain. The speed of the trolley and, in turn, crossflow speed, $u_a$, is varied between experiments.
The particle–fluid suspension that forms the fountain consists of a dilute mixture of fresh water, with density $\rho _f=1000$ kg m$^{-3}$, and silicon carbide particles of density $\rho _m = 3206$ kg m$^{-3}$ and major axis of length, $d$, in the range 22.8–212 $\mathrm {\mu }$m. For each particle size in our experiments, we estimate there to be a variation of size about the mean of, $\sigma \approx \pm 15\,\%$, calculated from the particle size range in Washington Mills SIC Particle Size Guide. Although the particles are not spherical, we use Stokes law to estimate the vertical fall speed of the particles, $v_s$, and control experiments carried out in previous studies (Mingotti & Woods Reference Mingotti and Woods2019, Reference Mingotti and Woods2020; Newland & Woods Reference Newland and Woods2021) show that the measured values of the sedimentation speeds are in good agreement with the Stokes fall speed estimate. The dilute particle–fluid suspension, with particle volume concentration $C_0$ typically 2.5 %, is stirred continuously and supplied to the injection nozzle using a Watson Marlow peristaltic pump at a constant volumetric flow rate, $Q_0$. The source buoyancy flux of the mixture $B_0$ is given by
where $\rho _m = C_0 \rho _p + (1-C_0) \rho _f$ is the bulk density of the mixture and $g$ is gravitational acceleration. The source Reynolds number, $Re = (u_0 r_0) / \nu _0$, where $\nu _0$ is the kinematic viscosity of the source fluid, for each experiment is maintained above 2000 to ensure the flow is turbulent. An electroluminescent light sheet (LightTape by Electro-LuminiX Lighting Corp.) is used to provide uniform lighting from one side of the tank and each experiment is filmed from a distance of 5 m using a Nikon D5300 digital camera at frame rate of 50 Hz. The frames captured in each experiment are analysed using MATLAB to extract bulk properties of the flow. Tables 1 and 2 display the conditions for each experiment.
3. Single-phase fountains in a crossflow
3.1. Experimental observations
Figure 4(ai–iii) shows a series of time-averaged experimental images of single-phase saline fountains with the same initial momentum, $M_0$, and buoyancy flux, $B_0$, but with increasing crossflow speed, $u_a$. From these time-averaged images, we isolated the vertical distribution of dye concentration along each vertical line through the fountain and fit a Gaussian distribution to these profiles. Using the position of the maximum and standard deviation of this Gaussian fit, we obtained an estimate of the centreline and outer edges of the fountain, as shown in figure 4(a-ii). Figure 4(b) presents the measured and theoretical heights of a fountain as a function of $P$. For $P<0.2$, the transient initial, $z_i$ and steady state, $z_t$, of the fountain are presented and for $P>0.2$, the maximum height of the fountain centreline is presented. Figure 4(c) presents the measured and theoretical distance at which the centre of mass of the fountain passes the nozzle height (the touchdown distance, $x_t$), as shown in figure 4(a-iii). Based on the morphology of these fountains we have characterised the flows as a function of $P$ into three regimes (Roberts & Toms Reference Roberts and Toms1987; Gungor & Roberts Reference Gungor and Roberts2009).
In the case of a weak crossflow, $P=0\unicode{x2013}0.2$, the fountain is only slightly deflected as it rises from the nozzle. The fountain entrains ambient fluid during its initial ascent which leads to an increase in the radius of the flow, until it reaches a maximum height, $z_t$. The fountain then collapses and, as it is only slightly deflected, interacts and entrains fluid from the upflowing region. Similar to a fountain in a stagnant homogeneous environment, the interaction between the upflow and downflow causes a reduction in the top height of the fountain to a steady-state value $z_t$. As shown in figure 4(b), in the region $P=0\unicode{x2013}0.2$, an initial height $z_i$ and steady-state height $z_t$ can be measured and the values are in agreement with the classical scalings of Turner (Reference Turner1966) for single-phase fountains in a stagnant environment. As the fountain collapses back on itself, we expect that the touchdown distance, $x_t$, is comparable to the width of the fountain at the maximum height. For comparison, we have plotted a scaling for the maximum radius of a fountain, $R_f$, as predicted by Burridge & Hunt (Reference Burridge and Hunt2013), that provides a lower limit for the touchdown distance of the fountain as $P \sim 0$.
As the speed of the crossflow increases so that $P$ lies in the range 0.2–0.5, the steady-state height of the fountain increases as, owing to the larger deflection of the fountain, the collapsing region of the flow no longer interacts with nor entrains fluid from the upflowing region. In addition, the transient initial height visible for fountains when $P<0.2$ is no longer observed and the touchdown distance of the fountain increases (figure 4c). Figure 4(a-iii) illustrates the case when $P>0.5$ and the crossflow speed is comparable to characteristic speed of the fountain. The fountain displays a decrease in the steady top height, $z_t$, and an increase in the touchdown distance, $x_t$, as P increases.
3.2. Modelling
A number of models have been proposed to describe single-phase fountains in a uniform crossflow. In figure 4(b,c) we present the estimates for the fountain top height, $z_p$, and touchdown distance, $x_t$, from models developed by Ansong et al. (Reference Ansong, Anderson-Frey and Sutherland2011), for low-moderate crossflow speeds, and Chu (Reference Chu1975), for moderate-high crossflow speeds. Ansong et al. (Reference Ansong, Anderson-Frey and Sutherland2011) extend the Lagrangian theory for fountains in stationary environments (Lee & Chu Reference Lee and Chu2003) and assume that the momentum flux near the source is predominately vertical and therefore neglect the development of streamwise vorticity. Although the model does not account for the reduction in $z_p$ that is observed as the crossflow speed increases, when $P=0.2\unicode{x2013}0.5$ the measured values of $z_p$ and $x_t$ in figure 4 show reasonable agreement with the model estimates.
For moderate-high crossflow speeds, the flow becomes blown over by the effective ambient flow (in the frame of the jet) and so the entrainment and mixing is dominated by the tilted fountain dynamics, which includes the effect of the coherent axial vorticity, rather than the vertical fountain dynamics, where the entrainment is smaller. To illustrate the transition between a vertical fountain and a bent-over fountain, figure 5 shows the vertical momentum flux of a fountain at the height at which the upward speed is equal to the crossflow speed, $\hat {M}$, calculated using the model presented in Ansong et al. (Reference Ansong, Anderson-Frey and Sutherland2011), as a function of the dimensionless crossflow speed, $P$. For a fountain to be controlled by the bent-over fountain dynamics, the horizontal speed of the fountain should adjust to the crossflow speed while the upward momentum flux is still of comparable size to $\hat {M}$. Figure 5 shows that this transitions occurs in the region $P\sim 1$.
For a fountain in this regime, Chu (Reference Chu1975) introduced a mechanistic model, based on the assumptions that the horizontal component of the fountain velocity, $u$, is equal to the crossflow speed, $u_a$, and using conservation of mass and momentum for the vertical flow at each point along the jet, including a simple parameterisation of the entrainment. A similar approach has also been used to describe the trajectory of buoyant plumes in a crossflow (Hoult et al. Reference Hoult, Fay and Forney1969; Hewett et al. Reference Hewett, Fay and Hoult1971; James et al. Reference James, Mingotti and Woods2022). Given the assumption that $u=u_a$, the horizontal position of the fountain centreline is given by
The fountain fluid has a vertical speed defined as $w={\rm d} z/{\rm d} t$ and a characteristic radius, $r$, perpendicular to the direction of the crossflow. The entrainment of ambient fluid leads to an increase in the radius of the fountain with height (Hewett et al. Reference Hewett, Fay and Hoult1971; Chu & Goldberg Reference Chu and Goldberg1974)
where $\alpha$ is an entrainment coefficient. As the buoyancy flux along the fountain remains constant in a homogeneous environment, the vertical momentum in each element of the fountain develops as it moves downstream
where $g'$ is the reduced gravity of the fountain fluid and $\gamma$ is a coefficient used to account for the momentum that is associated with any circulation in the fountain fluid, in addition to the added mass of ambient fluid that is displaced as the fountain rises and falls. Given the source buoyancy flux takes value $B_0$ this can be expressed as
which leads to the relation
In the momentum equation, we have included the factor of $\gamma$ in front of the source momentum term as well, as the initial source momentum is partitioned into the upward flow, the circulation and the added mass, which are not present in the vertical flow leaving the nozzle. Using (3.2), we integrate (3.5) with the negative sign with respect to time to obtain the expressions for the height of the fountain above the source, $z_u$, for the ascending fountain
where the transform $x=u_at$ has been used and $h_m$ and $h_f$ are the jet adjustment and buoyancy controlled length scales, as defined in § 1 and $x_p$ is the horizontal distance to the peak of the fountain where
and therefore the distance, $x_p$, and height, $z_p$, at the maximum height of the fountain are given by
For the descending plume which develops downstream from this point, using the positive sign we integrate (3.5) with respect to time to give expressions for the height above the source, $z_d$,
By differentiating equations (3.6) and (3.9) with respect to time, we obtain expressions for the vertical component of the fountains velocity in the upflowing
and downflowing regions of the fountain
3.3. Entrainment coefficient
To obtain a value of the entrainment coefficient, $\alpha$, we measured the spreading rate of the initial rise of the fountain as a function of height for experiments in which $P>1$. As described in § 3.1, we measure the radius of the fountain by fitting a Gaussian curve to vertical dye profiles taken along the length of the fountain and define the outer-edges of the fountain as a standard deviation, $\sigma$, away from the centre of mass. We find the relationship
and therefore, if we define the fountain radius as equal to the standard deviation, we find that
This value for the entrainment coefficient is consistent with that obtained by Ansong et al. (Reference Ansong, Anderson-Frey and Sutherland2011) who find that for a fountain in a slow-moderate crossflow, $\alpha =0.23$. These estimates of the entrainment coefficient are larger than those obtained for other free shear flows because the flow at hand includes coherent axial vorticity in the form of a double vortex structure as the flow becomes progressively more horizontal while it rises or falls – this increases the entrainment. Although our value of the entrainment coefficient is smaller than the value obtained by Chu & Goldberg (Reference Chu and Goldberg1974) and Chu (Reference Chu1975), their formulation did not account for the added mass and circulation of the flow and their measurements of the radius in fact suggested that $\alpha$ has value of about 0.25 (Chu Reference Chu1975) consistent with the present value.
Studies of turbulent buoyant plumes in a crossflow have found that, once the flow has fully developed, the spreading rate of the plume can be described using a value of the entrainment coefficient $\alpha =0.4- 0.6$ (Hoult et al. Reference Hoult, Fay and Forney1969; Hoult & Weil Reference Hoult and Weil1972; Chu & Lee Reference Chu and Lee1996; Devenish, Rooney & Thomson Reference Devenish, Rooney and Thomson2010a; James et al. Reference James, Mingotti and Woods2022). For a turbulent fountain in a crossflow, the descending region of the flow essentially behaves as a buoyant plume with an initial finite radius, $r_p$. However, at the peak of the fountain the flow includes significant circulation with an associated speed which we expect to scale with the bent-over fountain speed
As the flow descends from the top of the fountain, we expect it will gradually adjust towards the classic self-similar plume in a cross-flow as described by Hoult et al. (Reference Hoult, Fay and Forney1969), Hewett et al. (Reference Hewett, Fay and Hoult1971) and Slawson & Csanady (Reference Slawson and Csanady1967). In this adjusted flow, we expect that the circulation in the flow will scale with the mean flow; since the speed of a self-similar plume increases with vertical distance according to the relation,
it follows that the adjustment will require a distance which scales with the height of the fountain. Thus during the descent the flow will be in transition, and the entrainment may be intermediate between the fountain and the plume like flow regimes. Comparison of the model with our experimental data suggest that the entrainment coefficient $\alpha = 0.25\pm 0.03$ and added mass coefficient $\gamma = 0.25$ provides the best fit to the data; these are smaller than the values for the adjusted self-similar plume, $\alpha = 0.4$ and $\gamma = 0.47$ (James et al. Reference James, Mingotti and Woods2022) and so we adopt these in the present analysis.
Figure 4(b,c) presents the model estimates of the maximum height, $z_p$, and the touchdown distance, $x_t$, of the fountain respectively. The measured values of the maximum height show good agreement with the model estimates as $P>1$ and the model estimates of the touchdown distance, $x_t$, slightly over predicts the measured values, however follows the same trend.
4. Particle fountains with neutrally buoyant fluid
4.1. Qualitative observations
We now present a series of experiments exploring the dynamics of particle-laden fountains with neutrally buoyant interstitial fluid and the effect of varying the dimensionless fall speed of the particles, $U$, and the dimensionless crossflow speed, $P$ (table 2). Figure 6 displays images from experiments 2, 17, and 36 and highlights the three qualitative regimes identified in this study to describe the dynamics of particle fountains in a crossflow. For comparison of these three regimes we have presented instantaneous experimental images, time-averaged images with the backgrounds subtracted and the model estimates of the mean centreline and radius superimposed (3.6) and (3.9) and a simplified schematic diagram highlighting the key observations.
Regime I describes the case when the fall speed of the particles is significantly slower than the characteristic speed of the fountain ($U\ll 1$). In this regime the particles in the mixture remain well coupled with the fountain fluid and the flow essentially behaves as a single-phase fountain. From the time-averaged image, we can see that the model estimates of the centreline and radius of a single-phase fountain show very good agreement with the morphology of the particle fountain in this regime. This observation is consistent with observations of similar flows in various studies (Mingotti & Woods Reference Mingotti and Woods2016; Newland & Woods Reference Newland and Woods2021; James et al. Reference James, Mingotti and Woods2022).
As the size and the fall speed of the particles increase ($0.1< U<1.0$), the structure of the flow deviates from that of a single-phase fountain in a crossflow. In the instantaneous image for regime II, we can see that the particles and fountain fluid remain well mixed during the ascent of the fountain. The time-averaged image also shows that during the ascent of the fountain, the model predictions of the centreline and radius show good agreement with the experimental image. However as the mixture descends, there is some separation of particles from the mixture and in both the instantaneous and time-averaged images dyed red fluid is seen on the top-side of the flow whereas a dark region of particles is observed on the bottom-side of the flow. It is also evident that as the flow descends the trajectory of the mixture diverges from the single-phase model predictions and the dark region of particles reaches the base of tank more quickly than the prediction of a convecting flow.
Finally, as $U$ increases towards a value of 1, the fall speed of the particles approaches the characteristic fountain speed. The experimental images demonstrate that, in regime III, the structure of the flow is substantially different to that of a single-phase fountain in a crossflow. The instantaneous image shows that during the initial rise of the fountain, particles begin to sediment from the base of flow and settle through the water column. As a result, the bulk density of the mixture is reduced and when all the particles have separated from the fluid, the fluid becomes neutrally buoyant and therefore does not collapse to the base of tank but instead rises slowly through the water column due to a residual component of vertical momentum. In the time-averaged image, a dark region of settling particles can be seen below the rising red region of fluid. The dispersal distance of the particles from the source is significantly shorter than the distance reached by a single-phase fountain.
Thus far, we have presented the qualitative effect of varying the particle size on the dynamics of particle-laden fountains in a crossflow. We will now explore the influence of the crossflow speed on the dynamics of these complex multiphase flows. Figure 7 displays instantaneous and time-averaged images from three experiments in which the particle size and therefore dimensionless fall speed is kept constant, $U=0.62$, and the crossflow speed is varied. When the crossflow speed is small in comparison to the characteristic fountain speed, $P=0.13$, it is noticeable, from the instantaneous and time-averaged images, that the majority of the red fountain fluid is transported to the base of the tank with the particles and only a small fraction of fluid remains at or above the maximum height of the fountain. This indicates that the particles do not completely separate from the fountain fluid and some particles remain coupled with the fluid during the fountains descent. However as the speed of the crossflow increases, $P=0.66$, the fraction of fluid remaining at or above the maximum height of the fountain increases and the fraction collapsing to the base of the tank decreases. Furthermore as $P>1$, we can see that only a very small fraction of the fountain fluid is transported to the base of the tank and the majority of the fluid remains at the maximum height of the fountain. This trend suggests that when $U=0.62$ and the speed of the crossflow is increased, the fraction of particles that completely separate from the fountain fluid increases and therefore a larger fraction of fluid remains at a height comparable to the maximum height of the fountain rather than being carried back down to the base tank with the particles.
4.2. Quantitative results
As well as the qualitative observations presented above, we have measured the average vertical speed of the descending particles, $v_m$, and the average dispersal distances of the particles, $x_d$, as a function of $U$ and $P$. Figure 8 displays the method and results of the analysis carried out to determine the vertical speed of the descending particles. Panels (a-i) and (a-ii) are synthetic time-series created by isolating a vertical line of pixels, in the reference frame of the experimental tank, for a set of frames taken during an experiment. In this image, the horizontal direction represents time and the vertical direction represents the height of the tank. Each time-series records the rise and fall of the particle fountain as it traverses past the line of pixels, and can be used to measure the vertical speed of the descending particles as they settle to the base of the tank. The vertical speed is estimated by calculating the gradient of the particle-streaks formed as the particles descend through the tank, using a Hough transform (shown by the green and red lines). To measure the average vertical speed of the descending particles, we created over 25 time-series for each experiment that were equally spaced throughout the duration of the experiment and sampled the whole width of the cloud of descending particles. We measured the vertical speed of the particles at a height in the tank that is comparable to the height of the nozzle and did not observe any systematic variation of our measurements throughout the duration of the experiments. The average vertical speed of the particles, $v_m$, is plotted in figure 8(b,c) as a function of the dimensionless fall speed, $U$. Each data point is coloured according to the value of the dimensionless crossflow speed, $P$, of the experiment. To clearly demonstrate the varying dynamics as a function of the dimensionless fall speed, $U$, and dimensionless crossflow speed, $P$, we use two independent scalings in figure 8(b,c).
In figure 8(b) we have scaled the measured vertical speed of the descending particles, $v_m$, with the modelled vertical speed of a single-phase fountain at the touchdown distance, $w_d(x=x_t)$ (3.11). We term this convective speed, $v_c$. By scaling our measured data, $v_m$, with $v_c$ we can see that when $U<0.1$, in the vertical direction the descending particles are moving close to the vertical single-phase convective speed for all values of $P$. These data corroborate our earlier observations that when $U\ll 1$, the particles remain well-mixed in the fountain and the flow essentially behaves as a single-phase (regime I). As $U$ increases beyond 0.1, the measured vertical speed of the particles increases to values greater than the vertical component of the single-phase convective speed, $v_c$.
In figure 8(c) we have scaled the measured vertical speed of the descending particles, $v_m$, with the Stokes fall speed of the particles, $v_s$. This data shows that for $U\ll 1$ the particles are moving at vertical speeds that are much greater than their Stokes fall speed, and from figure 8(b) we know that this speed is comparable to the vertical component of the single-phase convective speed of the fountain, $v_c$. However as $U$ increases beyond 1 we see that in the vertical direction the particles descend at a speed close to their Stokes fall speed, which suggests that the particles have separated from the flow and are settling through the water column (regime III). We have shown how these two scalings help reveal the dynamics of the two end-member regimes, in which either the particles remain well mixed in the flow and the fountain behaves essentially as a single-phase (regime I) or the particles completely separate from the fluid and settle through the water column at their Stokes fall speed (regime III). In addition, this data also helps to demonstrate the effect of varying crossflow speed on the separation dynamics of the particles. For example, by examining the results of $v_m/v_c$ when $U=0.62$ (red-dashed box in figure 8b) we see that for slow crossflow speed ($P<1$, dark blue data point) the measured vertical speed of the particles is close to the vertical component of the single-phase convective speed at the touchdown distance, $v_c$, indicating that the particles remain coupled with the fountain fluid. However as the speed of the crossflow increases (green/yellow data points) the measured vertical speed of the particles increases to speeds significantly greater than the vertical component of the single-phase convective speed, $v_c$. By looking at the same data in figure 8(c) (red-dashed box), we see that for faster crossflow speeds (green/yellow data points) the measured vertical speed tends towards the Stokes fall speed of the particles, suggesting that the particles separate from the fluid and settle through the water column. This data verifies our observations in § 4.1, that although the particle size is kept constant, particles in a fountain in a faster crossflow speed tend to separate more completely than the particles in a fountain in a slower crossflow speed.
It is also of interest to measure the average dispersal distance of the particles, $x_d$, from the source. We define $x_d$ as the horizontal distance from the source to the centre of mass of the descending particle cloud at the height of the nozzle (schematics in figure 6). Once again to highlight the varying dynamics of the particle fountains as a function of $U$ and $P$, we present the measured dispersal distance scaled with two independent length-scales in figure 9(a,b) and have coloured each data point according to the corresponding value of $P$.
Figure 9(a) displays the average dispersal distance of the particles scaled with the horizontal distance to the peak of a single-phase fountain, $x_p$ (3.8a–c). These data show that for $U<0.1$, the average dispersal distance of the particles corresponds to the touchdown distance of a single-phase fountain, calculated from (3.6) and (3.9), for all values of $P$. As $U$ increases beyond 0.1, we see that the dispersal distance of the particles decreases at a rate that is dependent on the crossflow speed, $P$. The decrease in the particle dispersal distance is due to the separation of particles from the flow and subsequent settling of those particles through the water column. For small values of $P$ (dark blue points), $x_d$ starts to decrease in the region $U\sim 1$, which is in contrast to large values of $P$ where we observe a decrease in the particle dispersal distance as $U\sim 0.2$. This suggests that in the experiments with faster crossflow speeds, the particles begin to separate from the flow at smaller values of $U$. This observation is consistent with the data presented in figure 8, where we show that the speed of the descending particles is strongly dependent on the crossflow speed $P$.
To gain further insight into the separation and dispersal of the particles, we can consider the path a particle may follow in this flow. We have shown that as $U\ll 1$, the particles remain well-mixed in the fountain and follow the path of a single-phase fountain in a crossflow. Our qualitative and quantitative observations suggest that as $U$ increases beyond 0.1, particles separate from the fountain during either the ascent or descent phase of the flow and settle at their Stokes fall speed through the water column. As a characteristic length scale for the horizontal distance travelled by a particle that separates from the fountain fluid, we may consider the case in which a particle remains coupled to the fountain fluid to the peak of the fountain, distance $x_p$ from the source and height $z_p$ above the source, and then separates from the flow and settles to the base of the tank at the Stokes fall speed of the particle, $v_s$. Assuming that the particle is always moving at the speed of the crossflow, $u_a$, in the horizontal direction, the distance travelled by the particle from the source is given by
In figure 9(b) we have scaled the average particle dispersal distance, $x_d$, with this length scale. For $U\ll 1$, the average dispersal distance follows the single-phase touchdown distance and is significantly smaller than the ballistic trajectory, $x_s$. As $U\sim 1$, we see that for slow crossflow speed (blue points) the dispersal distance tends to $x_s$, which suggests that particle separation occurs near to the peak of fountain. However, as $P$ increases (light green/yellow points), we see that the dispersal distance tends to $x_s$ around $U=0.6$, but then shows a rapid decrease as $U$ continues to increase. We have shown that when $U\sim 1$ particles settle at their Stokes fall speed, and therefore the decrease in the particle dispersal distance must be a result of the particles separating from the fountain prior to reaching the peak of the fountain. As a simple estimate of the point of particle separation during the ascent of the fountain, using (3.10) (figure 10), we find the location at which the magnitude of the vertical velocity of the fountain is equal to the Stokes fall speed of a particle, $|w_u|=v_s$. Then following the above method, we assume that the particle remains well coupled to the fountain fluid until the condition $|w_u|=v_s$ is met, at which point the particle settles through the water column at its Stokes fall speed to the base of the tank. We have included this estimate of the dispersal distance in figure 9(b) (dotted line) using an average current speed from our experiments when $P>1.5$. This condition acts a lower limit for the dispersal of particles that may separate during the ascent of the fountain. These data show that for $P>1.5$, the data tend to this estimate. However, the bulk of the particles are dispersed further from the source.
5. Discussion
5.1. Regime diagram
In § 4, we have presented a set of qualitative and quantitative observations and introduced three distinct regimes to describe the dynamics of particle fountains in a crossflow. In regime I, when the dimensionless fall speed of the particles is small, $U\ll 1$, we show that the particles remain well coupled to the fountain fluid and the flow behaves essentially as a single-phase fountain. Our quantitative data in this regime are consistent with estimates from models of single-phase fountains in a crossflow, as described in § 3.2. In regime II, we observe the separation of some particles during the descent of the fountain which leads to a reduction in the dispersal distance of the particles. Finally, in regime III, when the fall speed of the particles is comparable to characteristic fountain speed $U>1$, we show that the particles separate from the flow during the ascent of the fountain, which significantly reduces the dispersal distance of the particles.
Using our observations, we have shown that these regimes are not only a function of the dimensionless fall speed of the particles, $U$, but also a function of the dimensionless crossflow speed, $P$. The quantitative data presented in § 4.2 (figures 8 and 9) reveal that as the speed of the crossflow increases, particles of a smaller size separate from the fountain fluid and settle at their Stokes fall speed through the water column rather than remaining coupled to the fountain fluid. To justify this finding, in figure 10 we present the magnitude of the vertical speed of a single-phase fountain for three different crossflow speeds as calculated from (3.10) and (3.11). Although these are theoretical curves, the model leads to centreline and radius profiles that provide a good fit to our experimental data, and this suggests that this model is an appropriate approximation for our experiments. These curves show that the vertical speed in the fountain decreases as the crossflow speed increases. By considering a parcel of fluid in a single-phase fountain that follows the path given by (3.6) and (3.9), the total vertical distance travelled by this parcel of fluid is
The total horizontal distance travelled by this parcel of fluid is given by the touchdown distance, $x_t$, which is found by substituting $z_d=0$ into (3.9), and we find that
Using (3.1), the vertical speed in the fountain is given by
and, therefore, the average vertical speed of a parcel of fluid in the fountain is
and, hence, we find that the vertical speed in the fountain, $|w|$, is proportional to $u_a^{-1/3}$, where $u_a$ is the speed of the crossflow.
For a particle to separate from the fountain fluid, we assume that the Stokes fall speed of that particle must exceed the magnitude of the vertical speed of the fountain, $v_s > |w|$. This assumption can be applied to particles that separate from the fountain during both the upflow and downflow regions of the fountain. Given that $|w| \sim u_a^{-1/3}$, the critical value of $U$ at which $v_s > |w|$ and particle separation occurs scales as $u_a^{-1/3}$. Therefore, we expect that the critical values of the dimensionless fall speed, $U_c$, that delineate regimes I and II, at which particles separate during the downflow region of the fountain, and regimes II and III, at which particles separate during the upflow region of the fountain, depends on $P^{-1/3}$.
To summarise the combined effects of both the dimensionless fall speed of the particles, $U$, and dimensionless crossflow speed, $P$, on the dynamics of particle-laden fountains, we now present the qualitative results of our experiments using a regime diagram (figure 11). Each experiment is represented by a point at its corresponding value of $P$ and $U$, and coloured according to the separation regime observed for that experiment (§ 4.1). We have also included the qualitative regimes, as defined in § 3.1, to describe the effect of the crossflow on the morphology of the fountain. The separation of particles in the fountain is dependent on the particle size and, hence, fall speed of the particles. We see that in the region $0.1< U<1.0$, there is a transition in dynamics from a regime in which no particles separate from the flow (regime I), to a regime in which particles separate on the downflow (regime II) and finally particles separate during the ascent of the fountain (regime III). It is also evident from our regime diagram, and previous descriptions, that the point at which the particles separate from the fountain is also dependent on the speed of the crossflow. As described previously, we expect that the value of $U$ at which particles separate from the flow scales as $P^{-1/3}$, therefore we have used this relationship to define the transitions between each regime in figure 11.
5.2. Application
Given the frequent appearance of particle-laden flows in the natural environment, the present work provides useful insight into the dynamics of these complex multiphase flows and how they interact with the ambient environment. Of particular interest is the evolution of deep-submarine explosive volcanic eruptions. In these eruptions, a mass flux of hot fragmented magma issues from a volcanic vent and mixes with a significant mass of cold seawater. After sufficient mixing, this flow becomes negatively buoyant and behaves as a multiphase fountain, consisting of a size distribution of pyroclasts and warm water, and the subsequent dynamics of the flow will be affected by the conditions of the ambient water column, such as ocean currents (Head & Wilson Reference Head III and Wilson2003; Cas & Simmons Reference Cas and Simmons2018; Newland et al. Reference Newland, Mingotti and Woods2022).
We can utilise the model presented in Newland et al. (Reference Newland, Mingotti and Woods2022) to calculate the conditions of an eruption column as it transitions to a negatively buoyant flow and, using the framework presented in this paper, we can describe how the magnitude of ocean currents and the size of pyroclasts may affect the eruption dynamics. In figure 12, using similar source conditions as presented in Murch et al. (Reference Murch, White, Barreyre, Carey, Mundana and Ikegami2020), we illustrate how an eruption of similar size to the explosive stage of the 2012 eruption of the Havre Volcano may be affected by ambient currents. The coloured boxes represent the range of measured current speeds and pyroclast diameters for the Havre Volcano (Murch, White & Carey Reference Murch, White and Carey2019; Murch et al. Reference Murch, White, Barreyre, Carey, Mundana and Ikegami2020) and, for comparison, the Axial Seamount (Barreyre et al. Reference Barreyre, Soule and Sohn2011) and Gakkel Ridge (Sohn et al. Reference Sohn2008; Pontbriand et al. Reference Pontbriand, Soule, Sohn, Humphris, Kunz, Singh, Nakamura, Jakobsson and Shank2012). To estimate the fall speed of the pyroclasts with varying diameter we follow the method of Ferguson & Church (Reference Ferguson and Church2004) and Barreyre et al. (Reference Barreyre, Soule and Sohn2011) and assume that the pyroclasts have a simplified spherical shape. This figure shows that the range of measured currents in the vicinity of the Havre Volcano are strong enough to lead to significant deflection of the eruption column and, owing to the size of pyroclasts observed, our regime diagram suggests that particle separation may play a critical role in defining the structure of the flow. As shown in § 4.2, this may lead to reduced dispersal distance of pyroclasts from the source. However, for an eruption of similar size at either the Axial Seamount or Gakkel Ridge, our work suggests that the dynamics of the flow would not be measurably altered.
It is important to note that, due to the technical and financial difficulties associated with studying the deposits of deep-submarine eruptions, the availability of comprehensive data sets is poor. Therefore, we expect that, given significant variations in the source conditions of eruptions such as vent depth and mass eruption rate, the dynamics explored in this study will be observed in the deep ocean and that the framework we have developed may help to interpret the deposits found on the seafloor.
6. Conclusions
In this work, we have presented a novel set of experiments that investigate the dynamics of particle-laden fountains in a uniform crossflow. We build a regime diagram to describe the effect of the dimensionless crossflow speed, $P$, and the dimensionless particle fall speed, $U$, on the structure and dynamics of these complex multiphase flows. By varying the dimensionless fall speed, $U$, of the particles we have identified three regimes that describe the dynamics of these flows. In regime I when $U<0.1$, we find that the particles remain coupled to the fountain fluid and flow behaves essentially as a single-phase fountain in a crossflow. In the transitional regime II as $0.1< U<1.0$, we observe that particles separate from the flow during the descent of the fountain. Finally, in regime III when $U>1.0$, the particles fall out of the flow during the ascent of the fountain and settle through the water column at a speed close to their Stokes fall speed. We have presented quantitative data on the dispersal distances and descent speed of particles and use a model of single-phase fountains in a crossflow (Chu Reference Chu1975) to help describe the separation of particles from the fountain fluid. We have found that the critical value of $U$ at which particle separation dominates the dynamics of the flow depends on the crossflow speed, such that $U_c \sim P ^{-1/3}$. Finally, we have contextualised our study by using it as a framework to help interpret the deposits of deep-submarine explosive eruptions.
Funding
This work was supported by the Natural Environment Research Council (grant number 2261860).
Declaration of interests
The authors report no conflict of interest.
Appendix. Comparison of fountain centreline estimates
To estimate the time-averaged centre of mass of a fountain, we follow the approach of James et al. (Reference James, Mingotti and Woods2022) who estimated the centre of mass of buoyant plumes in a crossflow by fitting Gaussian curves to vertical profiles of dye concentration along the length of the plume. In our experiments, we observe that as the fountain moves downstream and the horizontal flow speed downstream rapidly adjusts to the current speed, the vertical speed in the fountain becomes relatively small and therefore we expect that the centre and radius of the fountain can be tracked based on a vertical line through the flow. We test this assumption by tracking the radius and centreline of the flow along lines normal to the axis of the fountain, and compare these with the values of the radius and centreline as obtained from a vertical line through the fountain. For a typical example, we show the difference between these two approaches for a fountain with $P = 0.96$ in figure 13(a,b). In (c) we show a comparison of the two centreline measurements using these approaches, where it may be seen that there is very little difference between the two measurements. Finally, in (d) we show the root-mean-square errors between the measurement of the centreline as a function of the distance downstream for the two approaches and we see there is very little difference between the results of these methods.
The Gaussian fits provide a good estimate of the centreline and radius for distances at least 1–2 cm beyond the source; however, directly above the source, the concentration profiles do not represent a Gaussian distribution. Therefore, we carry out a linear interpolation from the final readings of the centreline and radius to the nozzle location, represented by the dotted red and black lines near the source in figure 13(a,b).