Hostname: page-component-cd9895bd7-jn8rn Total loading time: 0 Render date: 2024-12-18T21:23:27.655Z Has data issue: false hasContentIssue false

Errors in static pressure measurements due to protruding pressure taps

Published online by Cambridge University Press:  29 March 2006

H. Zogg
Affiliation:
Institute of Aerodynamics, Swiss Federal Institute of Technology, Zurich
H. Thomann
Affiliation:
Institute of Aerodynamics, Swiss Federal Institute of Technology, Zurich

Abstract

Errors in static pressure measurements caused by taps which protrude beyond the wall and disturb the boundary layer locally are investigated experimentally. The resulting error is presented as a function of the wall shearing stress, the protrusion height and the probe diameter in a representation similar to the calibration curve of Preston tubes. If suitably plotted, the present results can be made to fit this calibration curve to within the experimental accuracy, in spite of the differences between the geometries being compared.

Type
Research Article
Copyright
© 1972 Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Franklin, R. E. & Wallace, J. M. 1970 Absolute measurements of static-hole error using flush transducers J. Fluid Mech. 42, 33.Google Scholar
MacMillan, F. A. 1956 Experiments on Pitot tubes in shear flow. Aero. Res. Counc. E. & M. no. 3028.Google Scholar
Patel, V. C. 1965 Calibration of the Preston tube and limitations on its use in pressure gradients J. Fluid Mech. 23, 185.Google Scholar
Preston, J. H. 1954 The determination of turbulent skin friction by means of Pitot tubes J. Roy. Aero. Soc. 58, 109.Google Scholar
Shaw, R. 1960 The influence of hole dimensions on static pressure measurements J. Fluid Mech. 7, 550.Google Scholar