Hostname: page-component-cd9895bd7-lnqnp Total loading time: 0 Render date: 2024-12-19T04:18:17.456Z Has data issue: false hasContentIssue false

The design of piezometer rings

Published online by Cambridge University Press:  11 April 2006

K. A. Blake
Affiliation:
National Engineering Laboratory, East Kilbride, Glasgow, Scotland

Abstract

A mathematical model is developed with which the reading from a piezometer ring may be predicted from the individual wall static measurements and from this the conventional form of ring is shown to be unreliable in asymmetrical flow. An alternative form of ring known as the Triple-T is analysed and shown to provide a true mean pressure in all cases. It is recommended that this form be used in all future test work. Tests demonstrating the validity of the theory are described.

Type
Research Article
Copyright
© 1976 Cambridge University Press

Access options