Hostname: page-component-cd9895bd7-jn8rn Total loading time: 0 Render date: 2024-12-28T09:39:40.993Z Has data issue: false hasContentIssue false

Biosensor assay for determination of haptoglobin in bovine milk

Published online by Cambridge University Press:  29 March 2006

Maria Åkerstedt
Affiliation:
Department of Food Science, PO Box 7051, Swedish University of Agricultural Sciences, SE-750 07 Uppsala, Sweden
Lennart Björck
Affiliation:
Department of Food Science, PO Box 7051, Swedish University of Agricultural Sciences, SE-750 07 Uppsala, Sweden
Karin Persson Waller
Affiliation:
Department of Pigs, Poultry and Ruminants, National Veterinary Institute, SE-751 89 Uppsala, Sweden Department of Clinical Sciences, PO Box 7039, Swedish University of Agricultural Sciences, SE-750 07 Uppsala, Sweden
Åse Sternesjö
Affiliation:
Department of Food Science, PO Box 7051, Swedish University of Agricultural Sciences, SE-750 07 Uppsala, Sweden

Abstract

Despite more than 30 years of research into mastitis diagnostics, there are few alternatives to the somatic cell count (SCC) in practical use for identification of cows with subclinical mastitis. Mastitis is not only an animal welfare problem, but also affects the yield, composition and technological properties of milk. Hence, dairy cooperatives give farmers a premium quality payment to encourage low SCC although there is no clear scientific data defining the level of SCC in bulk tank milk that is associated with additional benefits in terms of milk quality. Recent research on alternative markers for inflammatory reactions in the lactating cow, e.g. in mastitis, includes investigations of the acute phase protein, haptoglobin (Hp). So far, the content of Hp in milk has mainly been studied in relation to mastitis diagnostics, with little attention given to its importance for milk composition and technological properties. At present, Hp in milk is measured using ELISA, but this technique is not suitable for routine large-scale analysis. In recent years, optical biosensor technology has been used for automated and rapid quantitative analysis of different components in milk, but so far not for analysis of acute phase proteins. The aim of the present study was to develop a rapid and sensitive biosensor method to determine Hp in milk. An affinity sensor assay based on the interaction between Hp and haemoglobin was developed using surface plasmon resonance (SPR) biosensor technology. The assay was used to analyse Hp in composite milk samples from cows without any clinical signs of mastitis and quarter milk samples with a weak to strong reaction in the California Mastitis Test (CMT). A commercial ELISA for determination of Hp in milk was used for comparison. The limit of detection (LOD) of the biosensor assay was determined as 1·1 mg/l. Within-assay and between-day variations were determined both with bulk tank milk spiked with human Hp and with composite milk samples containing bovine Hp. Coefficients of variation varied between 3·6 and 8·6% at concentrations between 4·0 and 12 mg/l, respectively. Agreement between the results obtained by the biosensor assay and the ELISA was satisfactory; however, the results obtained by the biosensor were generally lower than the results obtained by the ELISA. Possible explanations for this observation are discussed.

Type
Research Article
Copyright
Proprietors of Journal of Dairy Research 2006

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)