No CrossRef data available.
Article contents
An improved method for determining the nitrogen solubility of caseinates
Published online by Cambridge University Press: 01 June 2009
Summary
The nitrogen solubility index (NSI) method for the examination of caseinates was evaluated. It was found that widely scattering NSI values are mainly due to ineffective centrifugation and filtration of the caseinate dispersion. In order to avoid this, an improved combined centrifugation–filtration procedure was developed as an alternative to the original NSI method, using an Amicon micropartition system MPS-1 equipped with discs of filter paper. The micropartition devices can be centrifuged in a Gerber centrifuge of the type used for butyromctric fat determination. Several types of caseinates were evaluated with the new method and yielded a markedly smaller range of single values than were obtained with the NSI method.
- Type
- Original Articles
- Information
- Copyright
- Copyright © Proprietors of Journal of Dairy Research 1990