Hostname: page-component-cd9895bd7-mkpzs Total loading time: 0 Render date: 2024-12-24T18:49:01.260Z Has data issue: false hasContentIssue false

Use of ultrasonography to estimate cistern size and milk storage at different milking intervals in the udder of dairy cows

Published online by Cambridge University Press:  17 February 2003

Moez Ayadi
Affiliation:
Unitat de Producció Animal, Departament de Ciència Animal i dels Aliments, Universitat Autònoma de Barcelona, 08193 Bellaterra, Spain
Gerardo Caja
Affiliation:
Unitat de Producció Animal, Departament de Ciència Animal i dels Aliments, Universitat Autònoma de Barcelona, 08193 Bellaterra, Spain
Xavier Such
Affiliation:
Unitat de Producció Animal, Departament de Ciència Animal i dels Aliments, Universitat Autònoma de Barcelona, 08193 Bellaterra, Spain
Christopher H Knight
Affiliation:
Hannah Research Institute, Ayr, KA6 5HL, UK

Abstract

Four lactating Holstein cows (average milk yield: 20±3 l/d) were used to develop and validate a method for estimating the size of udder cisterns (Sinus lactiferi) using ultrasonography. A sectorial transducer probe of 5 MHz, placed in contact with the teat in a parallel cranial position, was used to obtain vertical scans of the udder in two perpendicular planes with the teat canal axis as reference. Udder scans for each udder quarter were taken randomly at intervals of 4, 8, 12, 16, 20 and 24 h after milking. Glandular parenchyma (echogenic) and lumen of the cisterns full of milk (anechogenic) were evident in the scans, the calculated area of the anechogenic portion being defined as cistern area. Cistern areas measured in perpendicular scans were highly correlated. Immediately after each measurement, cisternal milk was removed from each quarter using a teat cannula after i.v. injection of an oxytocin-receptor blocking agent. Alveolar milk from each quarter was then obtained by machine milking after i.m. injection of oxytocin. Cistern area and cisternal milk volume increased with length of milking interval showing a curvilinear pattern with a plateau after 16 h. Correlations between cistern area and cisternal milk volume were positive and significant (P<0·001) at all intervals but showed the highest values with the smallest residual standard deviations at 8 h (r=0·88) and 12 h (r=0·84). Since 8 h has previously been identified as a suitable time at which to determine cisternal milk volume for the purposes of defining suitability for different milking strategies, we conclude that ultrasonography provides a satisfactory, non-invasive method for determination of milk storage characteristics in dairy cows.

Type
Research Article
Copyright
Proprietors of Journal of Dairy Research 2003

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)