Hostname: page-component-586b7cd67f-rdxmf Total loading time: 0 Render date: 2024-11-22T05:03:28.879Z Has data issue: false hasContentIssue false

Can composite digital monitoring biomarkers come of age? A framework for utilization

Published online by Cambridge University Press:  23 April 2018

Christopher Kovalchick
Affiliation:
Eli Lilly Innovation Center, Cambridge, MA, USA
Rhea Sirkar
Affiliation:
Eli Lilly Innovation Center, Cambridge, MA, USA
Oliver B. Regele
Affiliation:
Eli Lilly Innovation Center, Cambridge, MA, USA
Lampros C. Kourtis
Affiliation:
Eli Lilly Innovation Center, Cambridge, MA, USA
Marie Schiller
Affiliation:
Eli Lilly Innovation Center, Cambridge, MA, USA
Howard Wolpert
Affiliation:
Eli Lilly Innovation Center, Cambridge, MA, USA
Rhett G. Alden
Affiliation:
Eli Lilly Innovation Center, Cambridge, MA, USA
Graham B. Jones*
Affiliation:
Clinical & Translational Science Institute, Tufts University Medical Center, Boston, MA, USA
Justin M. Wright
Affiliation:
Eli Lilly Innovation Center, Cambridge, MA, USA
*
*Address for correspondence: G. B. Jones, Ph.D., Clinical & Translational Science Institute, Tufts University Medical Center, 800 Washington Street, Boston, MA 02111, USA. (Email: [email protected])
Rights & Permissions [Opens in a new window]

Abstract

Introduction

The application of digital monitoring biomarkers in health, wellness and disease management is reviewed. Harnessing the near limitless capacity of these approaches in the managed healthcare continuum will benefit from a systems-based architecture which presents data quality, quantity, and ease of capture within a decision-making dashboard.

Methods

A framework was developed which stratifies key components and advances the concept of contextualized biomarkers. The framework codifies how direct, indirect, composite, and contextualized composite data can drive innovation for the application of digital biomarkers in healthcare.

Results

The de novo framework implies consideration of physiological, behavioral, and environmental factors in the context of biomarker capture and analysis. Application in disease and wellness is highlighted, and incorporation in clinical feedback loops and closed-loop systems is illustrated.

Conclusions

The study of contextualized biomarkers has the potential to offer rich and insightful data for clinical decision making. Moreover, advancement of the field will benefit from innovation at the intersection of medicine, engineering, and science. Technological developments in this dynamic field will thus fuel its logical evolution guided by inputs from patients, physicians, healthcare providers, end-payors, actuarists, medical device manufacturers, and drug companies.

Type
Research Methods and Technology
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
© The Association for Clinical and Translational Science 2018

Introduction and Current State

Incorporation of the term biomarker into medical parlance spans 4 decades and several of such have now become well known [Reference Paone1]. Prominent examples include HbA1c as a diagnostic marker for type II diabetes [Reference Lyons and Basu2], prostate-specific antigen level for prostate cancer prognosis [Reference Prensner3] and staging, and BRCA 1 and 2 for breast cancer genotyping [Reference James4]. Despite concerted efforts however (which have led to the discovery of extremely large and rapidly growing numbers of potential biomarkers) the translation and adoption of biomarkers as clinically validated surrogate endpoints of disease has moved at a relatively conservative pace [Reference Boone and Kelloff5]. Recent progress has been accelerated through availability of sensitive and rapid genomic, proteomic, and metabolomic interrogation tools [Reference Price6], and as these analyses are embedded in clinical studies it is likely that new validated endpoints will be established. Leading the efforts to co-ordinate development of new biomarkers in the United States is the National Biomarker Development Alliance [Reference Poste, Compton and Barker7]. Established in 2014, its expressed mission is to create standards that can be used for evidence-based biomarker development, and their subsequent adoption to advance precision medicine [Reference Poste, Compton and Barker7]. Given the regulatory significance of biomarkers in clinical medicine, a joint working group composed of Food and Drug Administration (FDA) and National Institutes of Health representatives was formed to establish a framework including relevant nomenclature and recently issued guidelines [8]. Published late 2016, the guidelines (referred to as Biomarkers, Endpoints, and other Tools or BEST) are envisioned as a live/working document that can evolve as new developments are recommended. The BEST framework advocates for 7 independent categories viz. (1) susceptibility/risk biomarkers, (2) diagnostic biomarkers, (3) monitoring biomarkers, (4) prognostic biomarkers, (5) predictive biomarkers, (6) pharmacodynamic/response biomarkers, and (7) safety biomarkers. It is noted that depending on context of use, biomarkers from different categories may interchange and overlap. For example, diagnostic and prognostic biomarkers may be classified as monitoring biomarkers when they are measured serially.

The pursuit and development of clinically relevant biomarkers has also fueled growth of the companion diagnostics industry—a notable example being the CD340 biomarker used to identify patients for trastuzumab (Herceptin®), the first in class Dx/Rx combination for treatment of HER2-positive breast cancers [Reference Ross9]. Harnessing the power of such omic profiling techniques has resulted in considerable progress in the oncology field [Reference Goossens10] and has impacted clinical trial stratification in other therapeutic areas including hypothyroid condition, cardiometabolic disease, as well as rare and orphan diseases [Reference Price6, Reference Ferlini, Scotton and Novelli11]. Although blood analysis can yield detailed and insightful diagnostic information, in the case of neurodegenerative disorders, routine analysis of cerebrospinal fluid for circulating biomarkers presents an obvious logistical barrier [Reference Ferreira12]. Compounding this problem is the fact that by the time many neurodegenerative diseases are diagnosed using conventional assessment methods, the disease may have advanced to a point where therapeutic options become limited. Accordingly, there is considerable interest in the application of noninvasive imaging techniques such as positron emission topography (PET) and functional magnetic resonance imaging to identify biomarkers of neurodegenerative disease based on metabolic and anatomic signatures, respectively. Given the potential impact of Alzheimer disease on the healthcare system and the relative low spend on this area relative to other chronic diseases such as cancer and rare diseases [Reference Kreitmair, Cho and Magnus13], such biomarkers are sorely needed, as the definitive marker remains assessment of amyloid plaque composition postmortem via autopsy [Reference Bouallègue14]. Such biomarkers could also provide surrogate endpoints for the development of chemopreventative agents, allowing appropriate longitudinal studies to be designed. One such study, known as the Alzheimer’s disease neuroimaging initiative (ADNI) is currently underway, correlating changes in patients memory and functional capacity with anatomic and metabolic signatures derived from magnetic resonance imaging/PET imaging [Reference Weiner15]. Though powerful, the high cost and limited availability of these imaging tools has fueled interest in methods able to identify and triage patients who are likely to benefit most. Numerous clinical studies are underway, including the Baltimore Longitudinal Study of Aging [Reference Kawas16], which aims to correlate decline in cognitive and physical function with onset of neurodegenerative disease. Complimenting these efforts are myriad large scale trials which track patient health indicators using commoditized electronic devices and wearable technologies [Reference Zhan17Reference Giggins, Clay and Walsh21]. Initial results have been promising, suggesting the very real potential for use of noninvasive digital tools which might track healthy individuals as they progress to early onset diseased states [Reference Wortley22, Reference Dorsey and Marks23]. As such, the era of digital monitoring biomarkers (DMBs) is dawning, with the capacity to revolutionize aspects of the healthcare ecosystem if implemented appropriately [Reference Wang, Azad and Rajan24Reference Dorsey26]. Continual advances in technology development and wireless network capacity globally suggest that technical barriers to adoption will be minimal, representing an unparalleled opportunity for the managed healthcare industry to transform itself [Reference Rodarte27, Reference Heldman28]. Herein we dissect the various DMB component systems, and, by incorporating contextual elements, offer a standardization framework which will inspire its rapid evolution.

Evolution of Digital Sensors for Clinical Use

The development of sensors for clinical use has been propelled by advances in the engineering of diagnostic and assessment tools. A digital sensor herein is defined as a device that employs an algorithm to measure physiological, biological, or cognitive information and provides feedback within a therapeutic area. The relative value of digital sensors reflects both the types of metrics that sensors can measure, and their adaptability to continuous monitoring of such metrics. In therapeutic settings, such continuous monitoring offers derived benefit with little to no intervention on the part of a clinician, caregiver, or patient, a prominent example being continuous glucose monitors for management of diabetes mellitus [Reference Tamborlane29, Reference Lind, Polonsky and Hirsch30]. The concept of a device containing a sensor that obtains a metric which provides insight and remedy for clinical decisions can be designed as of “closed-loop” embodiment. A prominent example in the diabetes area is the integrated system for glucose measurement and automated insulin delivery [Reference Doyle31] which evolved in part due to pressure from patient-advocates [Reference Lee, Hirschfeld and Wedding32] and has now been developed into a FDA-approved device, heralded as the “artificial pancreas” [Reference Bergenstal33]. A priori, the closed-loop concept is considered domain-agnostic, focusing on a single metric or therapy. However, importing domains into the clinical feedback loop of health management allows a patient, technology company or healthcare provider holistic insight to an individual’s overall health. For example, environmental events included in this domain are external factors that contribute to stress, and by extension heart rate and cardiovascular health. A digital sensor with closed-loop capacity and also involving domain is a photoplethysmograph (PPG) whose sensor provides heart rate information [Reference Tamura34]. The PPG sensors built into smartphones are not used to diagnose disease, so are therefore disease agnostic. However, a PPG sensor in a wristband can provide continuous heart rate monitoring and can then cross into the domain and diseased state, for example measuring difference in heart rate and blood volume changes which have been shown be used to diagnose peripheral arterial and vascular disease [Reference Allen35]. The power of these devices in cardiovascular health is evident. Though conventional gas chromatographic analysis measures analytes in serum to determine cholesterol levels that inform a physician to prescribe statins [Reference Kinter36], it is appreciated that this is merely one metric obtained at one timepoint. A device with PPG sensors that provides information related to arterial disease means that the same information might ultimately be obtained without a blood draw and with the benefit of continual assessment. An additional benefit of a patient worn monitoring device could be to provide a time sensitive alert—for example, detection of the early onset of ischemic stroke. Similar applications of DMBs can be expected in Parkinson’s disease. No effective intervention is available for Parkinson’s disease and treatment for tremor control is only available after diagnosis. However, there is hope that the use of wearable devices that track heart rate and movement (with accelerometers) may provide relevant information before disease onset, allowing early intervention [Reference Silva de Lima37]. The embodiment of the clinical feedback loop model is depicted in Fig. 1, where the relationship between patient and clinician is augmented by devices, sensors, and metrics. A patient will be engaged with their physician (clinical) on the specific intervention or therapy prescribed to treat a condition. The patient may be deeply in tune with both the intervention and the device they must deploy or use to monitor a condition progression, but may be ambivalent to the specific sensors within the device or the metric that is being measured. The intersection of the sensor and the metric which it analyzes draws on a rich and evolving mix of science and engineering.

Fig. 1 The closed-loop paradigm requires a concerted interdisciplinary approach to activate all domains. A traditional closed-loop system (left) can be used as part of a larger clinical feedback loop (right) that activates the 3 domains and different disciplines, allowing for a holistic and patient-specific approach to health and wellness management. HCP, healthcare provider.

Physiological, environmental, and behavioral domains as well as disease categories stem from this closed-loop model. Implicit in the model is that a single disease state can have multiple domains which create or affect it, and likewise a single domain can be applicable to multiple disease areas. Application of such a technology driven model as a dashboard to inform healthcare provision is examined in the following section, with emphasis on amplified insight being provided by importing domains within the loop.

Framework and Nomenclatures

At the heart of the framework proposed here is the ideal that driving and increasing value for the patient must be the central focus of an expanded biomarker paradigm. The digital evolution of the past decades has enabled the shift, but ultimately the value must reside with the patient. Fig. 2 (and the associated Box) outlines an ordered approach to the evolution of a biomarker agnostic to therapeutic area.

Fig. 2 A composite biomarker value ladder progression from direct and indirect measurements (first and second order) where the physiological domain exclusively is considered, to a contextualize composite measurement (fourth order) comprised of physiological, environmental, and behavioral domains.

Definition of first to fourth order: a first-order measurement is a direct measure of the disease or condition. It is the single metric used to either diagnose a state or quantify how a patient is managing their condition. Note that the simplicity or existence of a first-order metric can vary greatly between therapeutic areas. For example, a first-order measurement for diabetes is blood sugar level, an easily-obtained metric. This is compared to a number of neurodegenerative disorders where a detailed and complex brain synopsis is required postmortem.

A second-order measurement is an indirect measure of a state which has a known relation to the first-order metric. The second-order metric may often be used in place of the first order due to a variety of factors such as ease or simplicity of obtainment, cost, or intrusiveness. An example in the oncology space is in the detection of lung cancer, where a histological sample is obtained (first order) vs. a chest x-ray (second order). At large, the current framework of disease detection and monitoring is comprised of first and second order metrics. For both of these orders, the physiological domain associated with the different medical systems of the body is what drives measurements and diagnosis.

The digital progression has enabled a vision of where detection is heading via a third order, or composite biomarker, which is the combination of multiple metrics that provide insight to disease diagnosis and management. The increased value of a third order is demonstrated in therapeutic areas where a first and/or second order is either not known or not well defined. An example in the mental health space is the measurement of heart rate, sleep latency and heart rate variability, and their interaction to determine the onset or likelihood of an episode of depression. The composite biomarker is a paramount step towards self-identification and management, as multiple metrics that are simple and convenient for a subject to self-monitor and understand are combined into the composite biomarker without the burden or complexity of advanced diagnostic equipment only available solely in a clinical environment like a hospital or the physician’s office.

Ultimately, taking the third order composite biomarker and placing it in a subject’s surroundings creates a contextualized atmosphere. This is defined as the fourth order, where intrinsic and extrinsic factors are accounted for through behavioral and environmental parameters to provide ultimate insight into disease management. Consideration of an individual’s surroundings and their interaction with quantifiable data aids the understanding of how external factors affect that individual. As external factors play a pivotal role in one’s management of the disease, such as a patient’s emotional state or general feeling of well-being, bringing in this context is paramount to a complete management solution for subjects across all therapeutic areas.

The premise to the framework is a first- through fourth-order progression of metrics where the level of digital enablement increases directly with order. As a result of this progression, the framework highlights the state of simple diagnosis (first order) to a state where the patient is able to more effectively manage their condition or disease (fourth order). Note that while the outcomes of a first order biomarker are typically dependent on clinician intervention, the fourth order can be applied to a patient, clinician, or caregiver. In addition, as the orders progress from first to fourth, the behavioral and environmental domains augment the physiological domain.

As the landscape described here moves across orders, there are 3 broader shifts that can be identified: digitally enabled data acquisition, a movement from diagnosing disease states to the management of these disease states by a patient directly, and an increase in the overall value to the patient. In a general categorization across therapeutic areas, Fig. 3 shows some of the characteristics of first order (direct measurements) versus fourth order (contextualized composite metrics).

Fig. 3 Moving from traditional first-order measures to diagnose disease, a trend of the recent past, to the future where both diagnosis and management is enabled through activation of contextualized composite metrics and simultaneously reducing the threshold of patient adoption, and reducing costs through economies of scale [Reference Steinberg, Horwitz and Zohar38].

Generally, first order measurements are discrete in time and obtained only at specific instances. These discrete measurements often produce thin data, or data which is managed via a single variable at a time. The first order enables open-loop systems where the patient must play an active role, making decisions in their disease area such as dosing amounts or whether to seek more advanced therapy such as surgery. The first order can be viewed as high friction to the patient, ultimately providing limited insight in how to manage their disease. As the fourth order is approached, there exists a shift in many of these tenets. Data are acquired for multiple variables continuously over time, creating dense, longitudinal data sets. The patient interaction and burden is removed via closed-loop systems. Taking away these obstacles produce enhanced patient value because active interaction is no longer required, lowering the friction of living with and managing a disease.

Examples in Therapeutic Areas

A driving outcome of digital enablement of the contextualized composite biomarker is the ability to close the diagnosis and disease management loop while bringing in the domains inside the clinical feedback loop path. Ultimately, the value in a contextualized composite biomarker is the consideration of physiological and environmental factors, as demonstrated for diabetes in Fig. 4a . Instead of only monitoring glucose levels and controlling insulin delivery, behavioral aspects of diet, sleep [Reference Knuston, Ryden and Mander39], and exercise [Reference Riddell40] are considered. As a patient understands the impact of sleep quality on prevention of hypoglycemic events, they are enabled to make decisions in their behavior to impact their glycemic control. In addition, accounting for environmental factors such as whether a patient is at home or traveling, and incidents in one’s personal life such as a death in the family or stress due to a sick child provide enhanced value to all aspects of a person’s life and care circle.

Fig. 4 (a) Integrating the 3 domains (physiological, behavioral, and environmental) into the clinical feedback loop yields an opportunity to activate a contextualized composite metric that is relative to a specific person and provides optimized interventions at the right time. (b) A clinical feedback loop realizing the integration and interplay between comorbidities. An integrated system permits tailored interventions that are derived from the systematic and continuous interrogation of a person’s health and behavior. GPS, global positioning system; PET, positron emission tomography; PPG, photoplethysmogram.

Although the most omnipresent embodiment for closed-loop care is in the diabetes space with the advent of the artificial pancreas for interactive glycemic control and insulin delivery, the framework described above could in principle be applied to any number of therapeutic areas. Fig. 4b demonstrates the application of the framework presented here to multiple disease states. Examples are provided of therapeutic areas where a closed-loop embodiment already exists (diabetes), a closed-loop architecture is dependent on a caregiver due to lack of an effective drug therapy (Alzheimer disease), and where a closed-loop embodiment is in place to prevent a therapy or intervention altogether (general wellness). Perhaps more compelling than application to diseases is to wellness and disease prevention, as the majority of US healthcare investment recently is focused on disease care rather than prevention based in part on reimbursement models [Reference Yong, Saunders and Olsen41].

As mentioned, the diabetes space is the most predominantly well known in the closed-loop space with the advent of the artificial pancreas both in academic research and commercial product development [Reference Doyle31, Reference Bergenstal33]. A person with diabetes wears a continuous glucose monitor housing an electrochemical or optical sensor to acquire glucose measurements in the interstitial fluid (a second-order metric, of which a correlation to the first-order metric of blood glucose is established) [Reference Tamborlane29, Reference Lind, Polonsky and Hirsch30, Reference Lee, Hirschfeld and Wedding32]. Based on the glucose measurement, an insulin dosing recommendation is made and automatically delivered by an insulin pump [Reference Doyle31, Reference Bergenstal33]. In the neurodegenerative domain, specifically for Alzheimer disease, a PET scan of the brain is conducted and using image processing techniques (the sensor), the amount of amyloid is quantified. A closed-loop paradigm (more aptly described as a clinical feedback loop) currently necessitates the intervention of a caregiver to make decisions for the patient, due to the lack of treatment or intervention available to eliminate this amyloid plaque build-up in the brain, which is one of the leading hypotheses for the onset of Alzheimer disease.

Moving to the more general area or human wellness, the contextualized composite biomarker provides the opportunity for a person to be continually informed and make decisions passively to enhance their overall well-being. A key difference with this application is that there is no therapy or intervention by a clinician, but rather daily decisions made by individuals such as how to eat, how much to exercise, as well as sleep decision and behavior, amongst others. These behaviors ultimately have the potential to keep people healthier while reserving the intervention of a clinician or practitioner to more advanced disease progressions or emergency situations.

A potential extension from the contextualized composite biomarker would be to import this model to varying population segments and global health outcomes ubiquitously (Fig. 5). This extension to a “fifth order” would amplify the insight obtained for patients, clinicians, scientists, and engineers already achieved from embedding multiple domains inside the disease management model of the fourth order. In addition, it would enable activation in providing access to digital monitoring technologies irrespective of socioeconomic barriers [Reference Marshall42].

Fig. 5 The cumulative and additive impact of domain order of composite monitoring biomarkers in clinical diagnostics and population health.

The Physicians Role in Applying the Principles

Though compelling in concept, the litmus test of a framework for use of contextualized DMBs in healthcare lies in its implementation. One possibility is the development of a digital dashboard for healthcare providers which is informed by these principles. For example, a diagnostic tool in the form of a “digital pinwheel” could be envisioned where various first- to fourth order parameters feed algorithmic decisions. Such a tool already has precedent, for example, from DBM-based studies of the impact of physical environment on risk for Lyme disease [Reference Li43], and it is logical to consider how such devices could have been applied to monitor the spread of communicable diseases including SARS and avian influenza. Conversely, a prognostic digital pinwheel might also influence patient lifestyle and decision making, by rapidly assessing DBM’s based on composite metrics derived from physiologic, environmental, and behavioral inputs.

Opportunities and Challenges

The emergence of ubiquitous, economical, and highly sensitive digital monitoring devices has the potential to play a major role in healthcare diagnosis of the future [Reference Wang, Azad and Rajan24, Reference Wortley25, Reference Tamura34, Reference Steinberg, Horwitz and Zohar38, Reference Li43].

In tandem with these advances we have witnessed a paradigm shift in the adoption of many such tools into patients’ everyday lives, a consequence of the convenience of use of the devices and the widespread availability of broadband networks which they rely on. It is now imperative that the power of these systems is harnessed in broader elements of the managed healthcare ecosystem. It would seem timely for consumers who buy in to such a technology-centric approach. Recent data suggests that 14% of the US adult population are functionally illiterate (and, e.g., are unable to interpret prescribing information on drug packaging) [Reference Britt44] yet 68% own or have access to a smartphone [Reference Wang, Azad and Rajan24, Reference Torous, Rodriguez and Powell45]. The emergence of voice assisted peripherals (Google Alexa, Apple Siri, etc) offers an opportunity to close this gap in the drug prescribing space. As advocated herein however, digital tools offer the opportunity to fully engage additional parties in the healthcare sector. Various studies underway are linking patient captured data to healthcare outcomes and it can be expected that a move from healthcare diagnosis and disease management will be augmented by strategies for wellness and disease prevention [Reference Carrigan and Krahn46]. The adoption of these principles will require concerted and aligned effort between patients, providers, end-payors, and regulators. At the patient level, the term P4 medicine (predictive, preventative, personalized, and participatory) has been advanced, exemplified by longitudinal studies of large numbers of enrollees [Reference Hood and Price47]. Numerous challenges will need to be addressed for mass implementation, including concerns on data privacy and security, and the adoption of uniform standards agreed by regulators [Reference Kreitmair, Cho and Magnus13]. It has been noted that considerable variation exists even with basic step counting technologies, and this will require standardization if classification as medical devices is desired [Reference Case48]. Such data points incorporated as a component of a composite assessment, however, may allow a degree of self correction. Variability is also a concern with traditional clinical tests. An often cited example is the diagnosis of hyperthyroidism, which measures thyroid-stimulating hormone using an established range of 0.5–4.5 m IU/L [Reference Malinowski49]. Given variations in testing laboratory standardization, and the myriad other factors which are known to contribute to the reading, a composite approach to diagnosis is clearly preferable to a binary clinical decision based on a single (first order) metric [Reference Stockigt50]. As the field of DMBs evolves in managed healthcare it will impact all of its translational (T1–T4) components viz. translation to humans (T1), translation to patients (T2), translation to practice (T3), and translation to population health (T4). In the latter case, there is natural interest from end-payors and healthcare providers to lower costs and the very real potential to impact the insurance premium pools could exist. Many large organizations are now offering incentives for participants who enroll in wellness programs tied to monitoring biomarker trackers, and the actuary industry is likely to closely study these efforts for calculation of life insurance premiums [Reference Steinberg, Horwitz and Zohar38]. The potential may exist for monitoring devices to provide instantly accessible diagnostic information at systems level, as is now customary in the automotive industry via the OBD-II port in a vehicle. Equally possible could be tracking devices which provide incentive to refrain from potentially detrimental behaviors (e.g., alcohol, tobacco consumption), which although logical prompts potential ethical and legal issues [Reference Kreitmair, Cho and Magnus13]. Medicine is conventionally taught, diagnosed, and treated on the basis of the major systems of the human anatomy (central nervous system, pulmonary, cardiovascular, muscular, skeletal, and gastrointestinal, etc). The availability of reliable, DMBs for each system would allow healthcare professionals deep insight to diseases, and help fully realize the vision for precision medicine [Reference Collins and Varmus51].

Conclusion

The widespread availability of digital devices capable of tracking monitoring biomarkers is poised to transform the managed healthcare sector. Advances in device design, sensor development, and cloud computing technology are expected to drive their ability to capture clinically relevant data sets. Already, devices with ability to interrogate and differentiate between normal and diseased states are facilitating design of insightful longitudinal patient centric studies which will highlight their clinical utility. Exploiting such enormous potential requires considered decision making at all levels of the healthcare system, and composite approaches offer considerable merit. We speculate that use of these technologies will readily augment conventional medical approaches, and in select therapeutic areas (CNS, neurodegenerative disorders) could provide ground breaking insight [Reference Dorsey52]. Equally importantly, use of such strategies to promote patient wellness and early warning of progression into diseased states has the potential to offer marked economic benefit to managed healthcare systems, and is already beginning to bear fruit [Reference Price6]. To fully exploit the potential of digital medicine will also require the regulatory agencies to play a central role. Recent announcements from the FDA are encouraging, suggesting that digital health technologies will form a significant component of future guidance. For example the Digital Health Innovation Action Plan outlines numerous objectives, including a pilot precertification program for device developers [53]. Coupled with associated guidance documents this provides a framework for development of the digital biomarker industry [54], and the design of closed-loop devices [55]. Though the era of digital medicine is upon us, it is mindful to consider an oft-voiced quotation “A good decision is based on knowledge and not on numbers” (Plato). We would advocate that the key to modern medicine lies at the intersection of the two.

Acknowledgments

G.B.J. acknowledges funding from the NIH National Center for Advancing Translational Sciences through grant UL1 TR001064.

Disclosures

C.K., R.S., O.B.R., L.C.K., M.S., H.W., R.G.A., and J.M.W. are employees of Eli Lilly Corporation.

G.B.J. has no conflicts of interest to declare.

Footnotes

Current address: Hyalex Orthopaedics, Lexington, MA 02421, USA.

Current address: Novartis Pharmaceuticals, East Hanover, NJ 07936, USA.

References

1. Paone, JF, et al. Serum UDP-galactosyl transferase as a potential biomarker for breast carcinoma. Journal of Surgical Oncology 1980; 15: 5966.Google Scholar
2. Lyons, TJ, Basu, A. Biomarkers in diabetes: hemoglobin A1c, vascular and tissue markers. Translational Research 2012; 159: 303312.CrossRefGoogle ScholarPubMed
3. Prensner, JR, et al. Beyond PSA: the next generation of prostate cancer biomarkers. Science Translational Medicine 2012; 4: 127rv3.Google Scholar
4. James, CR, et al. BRCA1, a potential predictive biomarker in the treatment of breast cancer. The Oncologist 2007; 12: 142150.CrossRefGoogle ScholarPubMed
5. Boone, CW, Kelloff, GJ. Intraepithelial neoplasia, surrogate endpoint biomarkers, and cancer chemoprevention. Journal of Cellular Biochemistry Supplement 1993; 17: F37F48.CrossRefGoogle Scholar
6. Price, ND, et al. A wellness study of 108 individuals using personal, dense, dynamic data clouds. Nature Biotechnology 2017; 35: 747756.CrossRefGoogle ScholarPubMed
7. Poste, G, Compton, CC, Barker, AD. The National Biomarker Development Alliance: confronting the poor productivity of biomarker research and development. Expert Review of Molecular Diagnostics 2015; 15: 211218.CrossRefGoogle ScholarPubMed
8. FDA-NIH Biomarker Working Group. BEST (Biomarkers, EndpointS, and other Tools) Resource [Internet]. Silver Spring, MD: Food and Drug Administration, 2016. Co-published by National Institutes of Health (US), Bethesda, MD. (https://www.ncbi.nlm.nih.gov/books/NBK326791)Google Scholar
9. Ross, JS. Breast cancer biomarkers and HER2 testing after 10 years of anti-HER2 therapy. Drug News & Perspectives 2009; 22: 93106.Google Scholar
10. Goossens, N, et al. Cancer biomarker discovery and validation. Translational Cancer Research 2015; 4: 256269.Google Scholar
11. Ferlini, A, Scotton, C, Novelli, G. Biomarkers in rare diseases. Public Health Genomics 2013; 16: 313321.Google Scholar
12. Ferreira, D, et al. Improving CSF biomarkers’ performance for predicting progression from mild cognitive impairment to Alzheimer’s disease by considering different confounding factors: a meta-analysis. Frontiers in Aging Neuroscience 2014; 6: 287.CrossRefGoogle ScholarPubMed
13. Kreitmair, KV, Cho, MK, Magnus, DC. Consent and engagement, security, and authentic living using wearable and mobile health technology. Nature Biotechnology 2017; 35: 617620.CrossRefGoogle ScholarPubMed
14. Bouallègue, B, et al. Comparison of CSF markers and semi-quantitative amyloid PET in Alzheimer’s disease diagnosis and in cognitive impairment prognosis using the ADNI-2 database. Alzheimer’s Research & Therapy 2017; 9: 32.Google Scholar
15. Weiner, MW, et al. The Alzheimer’s disease neuroimaging initiative: a review of papers published since its inception. Alzheimer’s & Dementia 2013; 9: e111e194.Google Scholar
16. Kawas, C, et al. Age-specific incidence rates of Alzheimer’s disease: the Baltimore Longitudinal Study of Aging. Neurology 2000; 54: 20722077.Google Scholar
17. Zhan, A, et al. High frequency remote monitoring of Parkinson’s disease via smartphone: platform overview and medication response detection. 2016. Epub ahead of print, arXiv: 1601.00960.Google Scholar
18. Rentz, DM, et al. The feasibility of at-home iPad cognitive testing for use in clinical trials. Journal of Prevention of Alzheimer’s Disease 2016; 3: 812.Google ScholarPubMed
19. Adams, JL, et al. Multiple wearable sensors in Parkinson and Huntington disease individuals: a pilot study in clinic and at home. Digital Biomarkers 2017; 1: 5263.Google Scholar
20. Wortley, D, An, JY, Nigg, CR. Wearable technologies, health and well-being: a case review. Digital Medicine 2017; 3: 1117.Google Scholar
21. Giggins, OM, Clay, I, Walsh, L. Physical activity monitoring in patients with neurological disorders: a review of novel body-worn devices. Digital Biomarkers 2017; 1: 1442.Google Scholar
22. Wortley, D. The future of digital medicine in the aging society. Digital Medicine 2016; 2: 4345.Google Scholar
23. Dorsey, ER, Marks, WJ Jr. Verily and its approach to digital biomarkers. Digital Biomarkers 2017; 1: 9699.Google Scholar
24. Wang, T, Azad, T, Rajan, R. The emerging influence of digital biomarkers on healthcare [Internet], 2016 [cited Jan 16, 2018]. (https://rockhealth.com/reports/)Google Scholar
25. Wortley, DJ. The consumerization of digital medicine. Digital Medicine 2016; 2: 135139.Google Scholar
26. Dorsey, ER. A digital journal for a digital era. Digital Biomarkers 2017; 1: 13.Google Scholar
27. Rodarte, C. Pharmaceutical perspective: how digital biomarkers and contextual data will enable therapeutic environments. Digital Biomarkers 2017; 1: 7381.Google Scholar
28. Heldman, DA, et al. Telehealth management of Parkinson’s disease using wearable sensors: an exploratory study. Digital Biomarkers 2017; 1: 4351.Google Scholar
29. Tamborlane, WV, et al. Continuous glucose monitoring and intensive treatment of type 1 diabetes. New England Journal of Medicine 2008; 359: 14641476.Google ScholarPubMed
30. Lind, M, Polonsky, W, Hirsch, IB. Continuous glucose monitoring vs. conventional therapy for glycemic control in adults with type 1 diabetes treated with multiple daily insulin injections: the GOLD randomized clinical trial. Journal of American Medical Association 2017; 317: 379387.Google Scholar
31. Doyle, FJ III, et al. Closed-loop artificial pancreas systems: engineering the algorithms. Diabetes Care 2014; 37: 11911197.Google Scholar
32. Lee, JM, Hirschfeld, E, Wedding, J. A patient-designed do-it-yourself mobile technology system for diabetes: promise and challenges for a new era in medicine. Journal of American Medical Association 2016; 315: 14471448.Google Scholar
33. Bergenstal, RM, et al. Safety of a hybrid closed-loop insulin delivery system in patients with type-1 diabetes. Journal of American Medical Association 2016; 316: 14071408.Google Scholar
34. Tamura, T, et al. Wearable photoplethysmographic sensors—past and present. Electronics 2014; 3: 282302.Google Scholar
35. Allen, J. Photoplethysmography and its application in clinical physiological measurement. Physiological Measurement 2007; 28: R1.Google Scholar
36. Kinter, M, et al. Measurement of cholesterol in serum by gas chromatography/mass spectrometry at moderate mass resolution, with a nonendogenous cholesterol isomer as internal standard. Clinical Chemistry 1988; 34: 531534.Google Scholar
37. Silva de Lima, AL, et al. Large-scale wearable sensor deployment in Parkinson’s patients: the Parkinson@ Home Study Protocol. JMIR Research Protocols 2016; 5: e172.Google Scholar
38. Steinberg, D, Horwitz, G, Zohar, D. Building a business model in digital medicine. Nature Biotechnology 2015; 33: 910920.Google Scholar
39. Knuston, KL, Ryden, AM, Mander, BA. Role of sleep duration and quality in the risk and severity of type 2 diabetes mellitus. Archives of Internal Medicine 2006; 166: 17681774.Google Scholar
40. Riddell, MC, et al. Exercise management in type 1 diabetes: a consensus statement. Lancet Diabetes Endocrinol 2017; 5: 377390.CrossRefGoogle ScholarPubMed
41. Yong, PL, Saunders, RS, Olsen, L. The Healthcare Imperative: Lowering Costs and Improving Outcomes: Workshop Series Summary . Washington, DC: National Academies Press, 2010; PMID: 21595114.Google Scholar
42. Marshall, A. Wanted: biotech for an aging population. Nature Biotechnology 2017; 35: 597.Google Scholar
43. Li, X, et al. Digital health: tracking physiomes and activity using wearable biosensors reveals useful health-related information. PLoS Biology 2017; 15: e2001402.Google Scholar
44. Britt, R. Fourteen percent of US adults cant read [Internet], 2009. Live Science. (http://www.livescience.com/3211-14-percent-adults-read.html)Google Scholar
45. Torous, J, Rodriguez, J, Powell, A. The new digital divide for digital biomarkers. Digital Biomarkers 2017; 1: 8791.Google Scholar
46. Carrigan, P, Krahn, T. Impact of biomarkers on personalized medicine. Handbook of Experimental Pharmacology 2016; 232: 285311.CrossRefGoogle ScholarPubMed
47. Hood, L, Price, ND. Promoting wellness and demystifying disease: the 100K wellness project. Clinical Omics 2014; 1: 2023.Google Scholar
48. Case, MA, et al. Accuracy of smartphone applications and wearable devices for tracking physical activity data. Journal of American Medical Association 2015; 313: 625626.Google Scholar
49. Malinowski, JR, et al. Genetic variants associated with serum thyroid stimulating hormone (TSH) levels in European Americans and African Americans from the eMERGE network. PLoS One 2014; 9: e111301.CrossRefGoogle ScholarPubMed
50. Stockigt, J. Assessment of thyroid function: towards an integrated laboratory – clinical approach. Clinical Biochemist Review 2003; 24: 109122.Google Scholar
51. Collins, FS, Varmus, H. A new initiative on precision medicine. New England Journal of Medicine 2015; 372: 793795.Google Scholar
52. Dorsey, ER, et al. The first frontier: digital biomarkers for neurodegenerative disorders. Digital Biomarkers 2017; 1: 613.Google Scholar
53. US Food and Drug Administration. Digital health innovation action place [Internet], 2017 [cited Jan 16, 2018]. (https://www.fda.gov/downloads/MedicalDevices/DigitalHealth/UCM568735.pdf)Google Scholar
54. US Food and Drug Administration. Mobile medical applications [Internet], 2015 [cited Jan 16, 2018]. (https://www.fda.gov/MedicalDevices/DigitalHealth/MobileMedicalApplications/default.htm)Google Scholar
55. US Food and Drug Administration. Public workshop - physiological closed loop controlled devices [Internet], 2016 [cited Jan 16, 2018]. (https://www.fda.gov/medicaldevices/newsevents/workshopsconferences/ucm457581.htm)Google Scholar
Figure 0

Fig. 1 The closed-loop paradigm requires a concerted interdisciplinary approach to activate all domains. A traditional closed-loop system (left) can be used as part of a larger clinical feedback loop (right) that activates the 3 domains and different disciplines, allowing for a holistic and patient-specific approach to health and wellness management. HCP, healthcare provider.

Figure 1

Fig. 2 A composite biomarker value ladder progression from direct and indirect measurements (first and second order) where the physiological domain exclusively is considered, to a contextualize composite measurement (fourth order) comprised of physiological, environmental, and behavioral domains.

Figure 2

Fig. 3 Moving from traditional first-order measures to diagnose disease, a trend of the recent past, to the future where both diagnosis and management is enabled through activation of contextualized composite metrics and simultaneously reducing the threshold of patient adoption, and reducing costs through economies of scale [38].

Figure 3

Fig. 4 (a) Integrating the 3 domains (physiological, behavioral, and environmental) into the clinical feedback loop yields an opportunity to activate a contextualized composite metric that is relative to a specific person and provides optimized interventions at the right time. (b) A clinical feedback loop realizing the integration and interplay between comorbidities. An integrated system permits tailored interventions that are derived from the systematic and continuous interrogation of a person’s health and behavior. GPS, global positioning system; PET, positron emission tomography; PPG, photoplethysmogram.

Figure 4

Fig. 5 The cumulative and additive impact of domain order of composite monitoring biomarkers in clinical diagnostics and population health.