Hostname: page-component-cd9895bd7-jn8rn Total loading time: 0 Render date: 2024-12-18T23:45:58.582Z Has data issue: false hasContentIssue false

213 Extrapulmonary Gas Exchange Through Peritoneal Perfluorocarbon Perfusion

Published online by Cambridge University Press:  19 April 2022

Joshua L. Leibowitz
Affiliation:
University of Maryland
Warren Naselsky
Affiliation:
University of Maryland
Mahsa Doosthosseini
Affiliation:
University of Maryland
Kevin Aroom
Affiliation:
University of Maryland
Aakash Shah
Affiliation:
University of Maryland
Gregory J. Bittle
Affiliation:
University of Maryland
Jin-Oh Hahn
Affiliation:
University of Maryland
Hosam K. Fathy
Affiliation:
University of Maryland
Joseph S. Friedberg
Affiliation:
University of Maryland
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

OBJECTIVES/GOALS: For patients suffering from respiratory failure there are limited options to support gas exchange aside from mechanical ventilation. Our goal is to design, investigate, and refine a novel device for extrapulmonary gas exchange via peritoneal perfusion with perfluorocarbons (PFC) in an animal model. METHODS/STUDY POPULATION: Hypoxic respiratory failure will be modeled using 50 kg swine mechanically ventilated with subatmospheric (10-12%) oxygen. Through a midline laparotomy, two cannulas, one for inflow and one for outflow, will be placed into the peritoneal space. After abdominal closure, the cannulas will be connected to a device capable of draining, oxygenating, regulating temperature, filtering, and pumping perfluorodecalin at a rate of 3-4 liters per minute. During induced hypoxia, the physiologic response to PFC circulation through the peritoneal space will be monitored with invasive (e.g. arterial and venous blood gases) and non-invasive measurements (e.g. pulse oximetry). RESULTS/ANTICIPATED RESULTS: We anticipate that the initiation of oxygenated perfluorocarbons perfusion through the peritoneal space during induced hypoxia will create an increase in hemoglobin oxygen saturation and partial pressure of oxygen in arterial blood. As we expect gas exchange to be occurring in the microvascular beds of the peritoneal membrane, we expect to observe an increase in the venous blood oxygen content sampled from the inferior vena cava. Using other invasive hemodynamic measures (e.g. cardiac output) and blood samples taken from multiple venous sites, a quantifiable rate of oxygen delivery will be calculable. DISCUSSION/SIGNIFICANCE: Peritoneal perfluorocarbon perfusion, if able to deliver significant amounts of oxygen, would provide a potentially lifesaving therapy for patients in respiratory failure who are unable to be supported with mechanical ventilation alone, and are not candidates for extracorporeal membrane oxygenation.

Type
Education
Creative Commons
Creative Common License - CCCreative Common License - BYCreative Common License - NCCreative Common License - ND
This is an Open Access article, distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is unaltered and is properly cited. The written permission of Cambridge University Press must be obtained for commercial re-use or in order to create a derivative work.
Copyright
© The Author(s), 2022. The Association for Clinical and Translational Science