Hostname: page-component-586b7cd67f-dlnhk Total loading time: 0 Render date: 2024-11-23T17:28:11.546Z Has data issue: false hasContentIssue false

A dual-frequency measurement setup with fully integrated SiGe-based radar sensors for the size estimation of particulate matter

Published online by Cambridge University Press:  22 November 2024

Kennet Braasch*
Affiliation:
Chair of Microwave Engineering, Kiel University, Kiel, Germany
Alexander Teplyuk
Affiliation:
Chair of Microwave Engineering, Kiel University, Kiel, Germany
Daniel Bruhn
Affiliation:
Chair of Microwave Engineering, Kiel University, Kiel, Germany
Phillip Durdaut
Affiliation:
aerosense GbR, Kiel, Germany
Leve Freiwald
Affiliation:
aerosense GbR, Kiel, Germany
Florian Vogelsang
Affiliation:
Chair of Integrated Systems, Ruhr-University Bochum, Bochum, Germany
Nils Pohl
Affiliation:
Chair of Integrated Systems, Ruhr-University Bochum, Bochum, Germany
Michael Höft
Affiliation:
Chair of Microwave Engineering, Kiel University, Kiel, Germany
*
Corresponding author: Kennet Braasch; Email: [email protected]
Rights & Permissions [Opens in a new window]

Abstract

This paperpresents the measurement procedure as well as the calculations and theoretical background for the estimation of particle sizes with the help of a dual-frequency measurement setup. For the measurement, two fully integrated radar sensors are implemented which offer advantages over typically used technologies at high frequencies. The first sensor has a constant transmitting frequency of 90 GHz while the second sensor offers a possibility to vary the transmitting frequency over the entire D-band with frequencies between 110 and 180 GHz. With these frequencies, different sizes can be determined. The presented approach makes use of the different transitions between the linear increasing Rayleigh scattering regime and the Mie regime. With a fitting indoor measurement setup that resembles an industrial duct, the approach is verified for spheroid glass particles with a diameter of 0.875 mm. The results show a slight deviation from the expected value of particle sizes overall.

Type
Research Paper
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2024. Published by Cambridge University Press in association with The European Microwave Association.

Introduction

This publication is an extended version of the Conference paper presented at the European Radar Conference and published in its Proceedings [Reference Braasch, Bruhn, Teplyuk, Freiwald, Durdaut, Vogelsang, Pohl and Höft1].

Industrial pollution poses a significant threat to human health, particularly due to emissions resulting from combustion processes with particles in the micrometer and sub-micrometer range. Consequently, various governments and international institutions are committed to reducing atmospheric pollution. To achieve this objective, stringent limit values for air pollution have been established. For instance, in the European Union, the average mass loading of particulate matter with a diameter below 10 microns (PM10) should not exceed 40 μg/m3 averaged over a calendar year [2]. In addition, for industrial processes, a real-time evaluation of particles streams at the combustion process can be of great interest for the monitoring.

In order to find effective strategies for the mitigation of excessive emission, a reliable monitoring system is a crucial aspect. Among the various methods for the monitoring of particle streams available, Doppler radar technology stands out due to its ability to sense comparably large illuminated volumes while being contactless and non-invasive. Previous demonstrations have shown that radar sensors can measure the mass loading, velocity of fine particles, and mass flow inside the volume [Reference Teplyuk, Knöchel and Khlopov3].

One additional information is the dimension of the particle inside the flow which cannot be determined with one single radar sensor. Originally, two radar sensors with different frequencies were used for the determination of various water drop sizes and hail grains [Reference Doviak, Zrnic and Sirmans4]. Work on this measurement approach was later continued and improved [Reference Khlopov, Linkova, Voitovych and Cherniakov5, Reference Knöchel, Khlopov, Linkova, Teplyuk, Schünemann and Voitovych6]. The two sensors need to have different frequencies, hence the measurements is called a dual-frequency approach. Recently, this measurement approach has been implemented in a dual-frequency mm-wave radar, enabling the measurement of particles even in the sub-millimeter range [Reference Reinhardt, Teplyuk, Knöchel and Höft7]. This paper delves deeper into the measurements with fully integrated radar sensors, which can offer some significant improvements for practical applications.

In order to detect particulate matter in micrometer range, the radar sensor requires very sensitive receiver and high output power, which can be provided by using a high-power generator and a low-noise amplifier at the receiver input. The value of the dynamic range of the radar receiver is not required to be very high because the difference in the measured signal amplitudes vary in relatively low range of about 40 dB [Reference Teplyuk, Knöchel and Khlopov3]. In practice, there are unwanted interference, e.g., due to reflections from the measurement setup, poor isolation between transmitter and receiver. However, in the measurements conducted and discussed here, the particles whose dimensions can be estimated are bigger and therefore there is no need to improve the dynamic range and the output power of the radars.

Typically, at frequencies around 100 GHz or above, IMPATT diodes integrated into a waveguide housing are utilized due to their high output power which can reach 20 dBm or higher. This technology, however, has several drawbacks, including high production costs, limited reproducibility, frequency instability, and comparably large dimensions. Fully integrated sensors can significantly improve those drawbacks. On the other hand, the output power is significantly lower than that of IMPATT diodes. The entire sensor can be accommodated on a single chip, making it particularly advantageous for remote measurements where compact size and lightweight design are crucial. Additionally, the SiGe-based sensors exhibit improved frequency stability, resulting in a reduced noise floor. Furthermore, the output frequency can be readily adapted over a huge span which is difficult to achieve and only possible over a smaller span of frequencies with IMPATT diodes.

In this work, two fully integrated radar sensors based on the SiGe technology are utilized for a simultaneous dual-frequency measurement. The theoretical background needed for the determination of particle sizes is presented in order to apply the approach. A measurement with glass particles is carried out and elaborated to prove the concept of this measuring technique.

Theoretical background

In order to calculate the received power, the well-known radar equation needs to be adapted to the specific scenario of measurement of many small particles. The first important consideration are possible multiple scatterings inside the measurement volume which would have a significant influence on the calculation. However, multiple reflections can be neglected when $N_0\sigma_ts_v\ll 1$ is valid [Reference Skolnik8]. Here, N 0 stands for the particle concentration, σt is the total scattering cross section of a single particle, and sv is the side length of a cube representing the scattering volume. For the measurements investigated in this work, the particles are small in comparison to the wavelength and therefore the total scattering cross section of a single particle is comparably low. As a result, this condition can be assumed to be fulfilled in all measurements [Reference Goldhirsch9]. Consequently, the total received power of a volume with several small reflectors results from the sum of all individual reflectors or particles in this case. Applying this to the radar equation leads to the following variation for the total received power of a particle volume for this specific measurement setup:

(1)\begin{equation} P_R=P_T\frac{G_TG_R\lambda^2}{(4\pi)^3}\sigma_0V_{ef}. \end{equation}

In this context, σ 0 represents the specific radar cross section (RCS) of the volume, P stands for power, G for gain, λ for the wavelength of the signal, and Vef is the effective measurement volume. Indicators T and R mark the transmitted and received component, respectively. The RCS can be calculated using the particle concentration N 0 in the volume, a size distribution function of the various particle diameters $f_x(r_p)$ inside the measurement volume and the RCS of all individual particles as follows:

(2)\begin{equation} \sigma_0=N_0\int_0^\infty f_x(r_p)\sigma_p(r_p)dr_p. \end{equation}

The effective measurement volume is dependent on the radiation pattern of the antennas that are implemented for the measurement. It is the superposition of the receiving and transmitting antenna patterns $F_{T,R}$ and can be determined computing the following integral:

(3)\begin{equation} V_{ef}=\int_V\frac{F_T^2F_R^2}{R_T^2R_R^2}. \end{equation}

The only parameter in Eq. (1) that depends on the diameter of the particles is the RCS. Rearranging Eq. (1) with respect to RCS yields:

(4)\begin{equation} \sigma_0=P_R \frac{(4\pi)^3} {G_TG_RP_T\lambda^2V_{ef}}. \end{equation}

It is evident that, except for the received power PR, all parameters are system parameters that can be determined before the measurement itself. Consequently, with the measurement result and the knowledge of all system parameters, the RCS can be computed with the Eq. (4). However, Eq. (2) still has too many unknowns to determine the diameters from the measured results.

In order to improve this, a further measurement with a sensor at a different frequency can be performed. With two frequencies, two RCS can be calculated with the measured received power PR and the system parameters enabling a comparison between these two to obtain additional information regarding the particle size. By dividing the two RCS, the differential RCS (DRCS) is calculated as follows:

(5)\begin{equation} \sigma_d=\frac{\sigma_{0,1}}{\sigma_{0,2}}=\frac{\int_0^\infty f_x(r_p)\sigma_{p,1}(r_p)dr_p}{\int_0^\infty f_x(r_p)\sigma_{p,2}(r_p)dr_p}, \end{equation}

where the unknown particle concentration N 0 is already eliminated from the equation. Note that this is only valid when the dual-frequency measurement is simultaneous and therefore measures the same particle concentration inside the volume. However, analytical calculation with this equation is still not feasible due to the infinite integral. This can be avoided by making a priori calculations which can be compared to the measured results and allow conclusions to be drawn regarding the size of the particles. For these calculations, a further insight into the different scatterings of small particles is required.

Given that the measured particles in this work have a diameter below 1 mm and frequencies are between 90 and 180 GHz, the theories of Rayleigh and Mie scattering are primarily relevant for the examination. Both scattering theories are mainly applicable to spheres. The Rayleigh scattering is valid for spheres with a radius smaller than approximately $r=\frac{\lambda}{10}$ while the Mie scattering can be applied at higher radii [Reference Balanis10]. Moreover, the Mie theory provides an equation for the calculation of the normalized RCS. In Fig. 1, the calculated values are presented where the three relevant regimes are highlighted by different colors. In the Rayleigh regime (blue), the normalized RCS increases linearly with increasing radius. The second area is the Mie regime (green). Here, the normalized RCS is very dependent on the specific radius. For spheres with higher radius, the optical region begins where the normalized RCS approaches a constant value.

For the calculation of the particle radius inside a stream, the transition between the first two regions is of importance. As mentioned, the transition is not dependent on the absolute sphere radius but its ratio to the wavelength. Therefore, when measurements are performed with different frequencies, this transition occurs at different absolute sphere diameters. Additionally, when the particles are dielectric spheres, the refractive index or the permittivity has an influence on both the overall reflected power and on the position of the transition [Reference Ruck, Barrick, Stuart and Krichbaum11]. With the knowledge of the particles permittivity and the transmitting frequency, the RCS can be calculated with the Mie theory.

Figure 1. Calculated monostatic RCS of a sphere depending on its radius in ratio to the signal wavelength.

Figure 2 shows the exemplary calculated DRCS of a dual-frequency approach with frequencies at $f_1=160$ GHz and $f_2=90$ GHz with spherical glass particles with a permittivity of $\varepsilon_r = 3.8+0.005j$ [Reference Chen, Nguyen and Afsar12]. To verify these calculated results, the monostatic RCS of a single sphere is computed for both frequencies with a full-wave simulation software and compared. The simulated results agree with the calculations, thus confirming this approach. Initially, a constant value can be observed in Fig. 2. This occurs at particle sizes within the Rayleigh scattering regime, thereby both measured RCSs are increasing linearly with particle size. Inside the Rayleigh regime, the RCS of a single particle can be calculated in a simplified way as follows [Reference Ruck, Barrick, Stuart and Krichbaum11]:

(6)\begin{equation} \sigma_{rayleigh}=\frac{128}{3} \frac{\pi^5r_p^6}{\lambda^4} \frac{(\varepsilon'-1)^2+\varepsilon^{\prime\prime 2}}{(\varepsilon'+2)^2+\varepsilon^{\prime\prime 2}} \end{equation}

where $\varepsilon'$ corresponds to the real part and $\varepsilon^{\prime\prime}$ to the imaginary part of the permittivity. Because both devices measure the same particle radius and permittivity, everything besides the wavelength can be reduced. Note, that is valid for the chosen particles of glass due to the almost constant permittivity at the investigated frequencies [Reference Chen, Nguyen and Afsar12]. In the given exemplary scenario, the constant DRCS value can then be calculated with Eq. (6) to:

(7)\begin{equation} \frac{\sigma_{d,1}}{\sigma_{d,2}}=\left(\frac{f_1}{f_2}\right)^4=\left(\frac{160\,\text{GHz}}{90\,\text{GHz}}\right)^4=9.99\,\text{dB}. \end{equation}

Figure 2. Calculated monostatic DRCS for a constant frequency $f_1=90$ GHz and $f_2=160$ GHz. The blue area marks the area of unambiguity.

Figure 3. Calculated monostatic DRCS for a constant frequency $f_1=90$ GHz and various frequencies between $f_2=110$ GHz and $f_2=180$ GHz.

The blue-marked area in Fig. 2 indicates the area of unambiguity. In this segment, the scattering of the higher frequency signal is already in the Mie regime, while the lower frequency signal still is within the Rayleigh regime. Here, a measured DRCS corresponds to one specific pre-calculated DRCS and can therefore be connected to the corresponding particle radius rp. With further increasing particle radius, both signals are scattered in the Mie regime and the measured DRCS cannot be assigned to one distinct radius. The two frequencies of the measurement setup, therefore, have a significant influence on which particle diameters can be detected and should be chosen carefully depending on the measured particles. A dynamic choice of frequencies could also be advantageous to shift the area of unambiguity during the measurement to obtain further information. Furthermore, a bistatic approach also influences the steepness inside the area of unambiguity as the energy is not reflected equally to all angles in the Mie range. However, the position of the minimum does not change and the determinable maximum radius does not change.

These calculations are assuming a monodisperse particle stream, which is not always the case in practical applications. Several studies have shown that there are two applicable size distribution models for the naturally occurring particle streams [Reference Heintzenberg13, Reference Fang, Patterson and Turner14]. One is the log-normal or Galton distribution while the second one is the Waloddi Weibull distribution. These distributions can have a significant influence on the actual DRCS as they are included in Eq. (5). However, in real measurements, the distribution typically is not known beforehand making it significantly more complex to determine the radius.

Radar sensors

In this work, two fully integrated radar sensors are used for the simultaneous dual-frequency measurement. One sensor has a fixed frequency in the W-band at 90 GHz while the frequency of the second sensor can be varied over the entire D-Band. To show the influence on the DRCS, in Fig. 3, the calculation results over different particle radii rp are shown. The detectable particle radius decreases with increasing frequency f 2 which is expected due to the transition between Rayleigh and Mie scattering being at lower particle radius. Furthermore, the constant value at lower radius is changing as expected by Eq. (7).

The two integrated radar systems have been previously introduced in prior articles [Reference Kueppers, Jaeschke, Pohl and Barowski15, Reference Jaeschke, Bredendiek, Kueppers, Schulz, Baer and Pohl16]. Figure 4 shows a top view of the sensors. The W-band sensor consists of only the sensor itself with a transition from microstrip to rectangular waveguide, which is located in the upper half of Fig. 4(b), where the golden plates are shown [Reference Hansen, Kueppers and Pohl17]. On the other hand, the D-band sensor is integrated in a setup which provides further possibilities of connectivity and offers an integrated data acquisition unit which can be seen in Fig. 4(a). The waveguide transition is on the top of the picture. Both sensors are installed inside a dust proof metallic housing.

Figure 4. View of the fully integrated sensor of the (a) D-band and (b) W-band.

Figure 5. Simulated scattering pattern of one sphere when the radius is (a) inside the Rayleigh regime and (b) inside the Mie regime.

The W-band sensor exhibits an output power of approximately −2 dBm at a stable operating frequency of 90 GHz. For the processing of the measurement results, an external data acquisition unit is added to digitize the signal with a resolution of 24 bit and a sampling frequency of 96 kHz. The D-band sensor has a data acquisition unit with a resolution of 24 bit and a sampling frequency of 256 kHz, which is connected to RF front end as seen in Fig. 4. With its software, various operational parameters can be adjusted. For instance, the transmitting frequency can be swept over the entire band and the internal amplifier can also be set to a specific value. The output power is approximately −8 dBm. Both receivers have a noise figure of app. 17 dB.

In this measurement, rectangular horn antennas are used due to the well-defined radiation pattern. For the manufacturing of the antennas, a negative is milled out of conductive metal and the antenna is then made with electroplating. This process leads to reliably low tolerances in dimensions. The dimensions of the aperture are $a_D=7.7$ mm, $b_D=5.8$ mm with a length $l_D=29$ mm for the D-band antenna and $a_W=14.5$ mm, $b_W=10.2$ mm with a length of $l_W=58$ mm for the W-band antenna. In contrast to the measurements presented in [Reference Braasch, Bruhn, Teplyuk, Freiwald, Durdaut, Vogelsang, Pohl and Höft1], a quasi-monostatic approach is implemented for both sensors. Figure 5(a) and (b) shows the exemplary scattering pattern of one sphere when the diameter is inside the Rayleigh or Mie regime, respectively. Note that the source for this scattering is located at ϕ = 0 and θ = 0. Inside the Rayleigh regime, the power is scattered in the shape of a dipole as shown in Fig. 5(a). The measured power with a bistatic setup would therefore be almost constant. However, in the Mie regime, there are strong minima depending on the angle and the particle diameter as seen in Fig. 5(b) which leads to differences of the received power of up to 20 dB [Reference van de Hulst18]. This is avoided with the quasi-monostatic setup implemented here, which also still includes a separation of transmitting and receiving path.

Measurement setup

In comparison to the presented work in [Reference Braasch, Bruhn, Teplyuk, Freiwald, Durdaut, Vogelsang, Pohl and Höft1], the setup is adjusted to further improve the repeatability of the measurements and to have a more stable particle flow. Figure 6 shows a schematic of the overall setup. The presented setup is a proof-of-concept for this method to show its possibilities for future applications. At the top right, a fan accelerates the air as marked to the velocity vair which is estimated to be around 9 $\frac{\text{m}}{\text{s}}$. The particles are induced at the top with a velocity vparticles and experience further acceleration due to the air flow as well as the gravity. This velocity is estimated to be around 3 $\frac{\text{m}}{\text{s}}$ inside the measurement volume. In order to improve the distribution over the cross-section of the tube, the narrow part as seen in the schematic figure is added which essentially realizes a de Laval nozzle [Reference Rezende19]. This leads to a higher velocity of the air and the particles inside the narrower tube, and with the continuous enlargement afterward, the particles and velocity are more evenly distributed. The pipes above the de Laval nozzle are made out of sheet steel. Below the nozzle where the actual measurements take place, the pipe is made out of transparent acrylic glass with a permittivity of 2.6 and a thickness of 4 mm. The acrylic glass pipe has a length of 2 m, resulting in an overall length of over 3 m for the complete setup. The particles are induced by a dispenser with a constant mass flow. At the bottom of the tube, the particles are captured so they are not induced into the environment.

Figure 6. Schematic representation of the measurement setup.

The realized setup with the attached radar sensors is shown in Fig. 7. Aluminum profiles are used for the supporting frame due to its flexibility for adaptation. Fastened to the aluminum profiles are attachments to secure both mounts for the measuring volume as well as for the W-band sensor. Furthermore, the sensor is attached to a special fixture that allows the adaption of the angle. The D-band sensor is mounted on a tripod which offers a similar possibility to freely adapt the angle and position. With a digital protractor, this angle can then be precisely set.

Figure 7. Measurement setup with both radar sensors.

Figure 8. Directivity of the D-band horn antennas.

Before the measurements itself are conducted, the system parameters for both devices can be determined with Eq. (4). Both the gain as well as the effective scattering volume Vef are dependent on the radiation pattern of the antennas [Reference Teplyuk, Knöchel and Khlopov3]. The measured radiation patterns of the manufactured antennas are shown in Figs. 8 and 9, respectively. Furthermore, the gain of the antennas are measured to be 20 dB for the W-Band antenna and 19 dB for the D-Band antenna.

For the calculation of the effective measurement volume Vef, a second degree polynomial is used to approximate the main lobe of the antennas. These functions are implemented for FT and FR in Eq. (3). Due to the implementation of identical antennas, $G_R = G_T$ is valid in both cases. In order to incorporate the angle of the antennas in the calculation, a local coordinate system is used that transforms the global Cartesian coordinates depending on the angle of the antennas. Due to the quasi-monostatic setup, the distance between receiving and transmitting antenna is assumed to be equal. The resulting function for the two sensors in the W-band and the D-band:

(8)\begin{equation} V_{ef}=\int_V\frac{F_{T}^2 \cdot F_{R}^2}{R_{T,R}^2} \end{equation}

is then integrated. The limits of the integral are set at a radius of 75 mm around the center of the tube because most of the particles are concentrated in the center. Table 1 shows a comparison of the system parameters for both sensors where the angle of the antennas is set to 30.

Figure 9. Directivity of the W-band horn antennas.

Table 1. Comparison of the two systems of the W-band and the D-band

With these calculations, the systemic parameter can be determined before the measurement itself is conducted. All parameters besides the received power in Eq. (4) are known and will be combined to a systemic value S. The measured results are as follows:

(9)\begin{equation} S_W = \frac{(4\pi)^3}{G^2P_T\lambda^2V_{ef}} \approx 2.52\cdot10^5\frac{\text{m}^2}{\text{W}}, \end{equation}
(10)\begin{equation} S_D = \frac{(4\pi)^3}{G^2P_T\lambda^2V_{ef}} \approx 2.36\cdot10^6\frac{\text{m}^2}{\text{W}}, \end{equation}

where GT and GR are combined to G 2 due to the identical transmitting and receiving antenna.

Measurement results

A measurement is carried out with glass particles with a mean diameter of 0.875 mm to prove the concept. Before the actual measurement itself, the particle flow of these particles with the implemented particle dispenser is measured with the help of a precise weighing scale. The particles are dispensed into the scale for one minute. The determined mass flow is 1.5 gs−1. To ensure that the measured particle concentration is the same with both sensors, the measurement volume must be within the same range for each. Therefore, the elevation angle of the sensors should be identical for both setups and are set to an angle of 30 as shown in Fig. 6.

The signal to noise ratio (SNR) of the measurement results is shown in Figs. 10 and 11, respectively. In order to minimize the impact of random noise on the measurement, 1000 spectra of constant particle streams are measured and averaged in the presented results. Both measurements show a very prominent peak with an SNR above 20 dB. The Doppler frequency varies between the two results as expected from $f_D=\frac{2v}{\lambda}$.

Figure 10. SNR of the measurement with the W-band sensor.

Figure 11. SNR of the measurement with the D-band sensor.

The SNR of this result can be integrated in order to obtain the received power from scattering of the particles inside the measurement volume. Note that the amplification inside the data acquisition unit has to be considered. With the determined received power PR, the two individual RCS can then be calculated by:

(11)\begin{equation} \sigma_{0,W,D}=P_R\cdot S_{W,D}. \end{equation}

The next step is the calculation of the DRCS with these two values as shown in Eq. (5):

(12)\begin{equation} \sigma_d=\frac{\sigma_{0,D}}{\sigma_{0,W}}=0.5848=-2.33\,\text{dB}. \end{equation}

This value can now be compared to the predetermined plot that is shown in Fig. 2. For the given frequencies of 160 and 90 GHz, the calculated DRCS corresponds to a particle radius of either 0.396 mm or 0.44 mm. The latter value is very close to the expected mean radius of 0.4375 mm with a deviation of under 2 %. Since the measured particles lie outside the area of unambiguity, the distinction between the two radii in question can only be made using additional information. Typically, there is some pre-knowledge regarding an expected particle size for an application, which can be used to select proper frequencies for the measurement. However, additional information could also be obtained by adding more measurements like a third sensor at a different frequency. The difference between the calculated and the real values is possibly due to the unknown distribution of the particle radii. As discussed in the theoretical chapter, these calculations are mainly for monodisperse particle streams and different particle distributions can potentially effect the results of the measurement. These results not only prove that this approach offers a sufficient method to estimate the dimension of particles even when the exact distribution of the different sizes is not known, but it also proves that the utilized fully integrated SiGe-based sensors are sufficient for the measurements of particles with these dimensions.

Conclusion

This work presents a dual-frequency measurement setup for the estimation of sphere particle diameters. Two fully integrated radar sensors are implemented for the measurement which can offer significantly enhancement to a practical measurement due to the light-weight and small dimensions. The needed theoretical calculations for the estimation are presented and confirmed with a measurement of spherical glass particles inside an indoor measurement setup. The presented results show some deviation from the expected values for the radius which can be traced back to the unknown size distribution of the particles around the known mean diameter. However, the results are close to the mean diameter and confirm that this approach is sufficient for the estimation even without further knowledge of the distribution.

Acknowledgements

This work was supported by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) – 495198532.

Competing interests

The author(s) declare none.

Kennet Braasch received the B.Sc. and M.Sc. in electrical engineering and information technology from the Kiel University, Germany in 2018 and 2020, respectively. Since 2020, he is working as a Research Associate and pursuing the Dr.-Ing. degree as a member of the Chair of Microwave Engineering with the Institute of Electrical Engineering and Information Technology at Kiel University. His current research topics interest includes radar technology, antennas, passive components, and particle measurements with various radar sensors.

Alexander Teplyuk received the diploma degree in technology of aircraft construction from the National Aerospace University, Kharkiv, Ukraine, in 2000. From 2001 to 2006, he was a Research Engineer with the Radar Department of the Institute of Radiophysics and Electronics of National Academy of Sciences of Ukraine, Kharkiv, Ukraine. In 2012, he received the Dr.-Ing. degree in electrical engineering from Kiel University, Kiel, Germany. Since 2012, he has been a Research Fellow with the Chair of Microwave Engineering of Kiel University. His current research interests include radar technology, antennas, microwave sensors and components, and electromagnetic scattering in disperse media.

Daniel Bruhn received the B.Sc. and M.Sc. in electrical engineering and information technology from the Kiel University, Germany in 2021 and 2023, respectively. He is currently pursuing the Dr.-Ing. degree as a member of the Chair of Microwave Engineering at the Institute of Electrical Engineering and Information Technology of the Christian-Albrechts-Universität zu Kiel. His research interest includes radar-based particle measurements as well as microwave moisture measurements.

Phillip Durdaut received the B.Eng. degree in electrical engineering from the Hamburg University of Applied Sciences, Hamburg, Germany, in 2013, and the M.Sc. and the Dr.-Ing. degrees in electrical engineering from Kiel University, Kiel, Germany, in 2015 and 2019, respectively. From 2015 to 2021, he was a Research Associate with the Chair of Microwave Engineering at Kiel University with main research interests in magnetic field sensors based on micromechanical resonators, low-noise instrumentation, and millimeter-wave radar sensors. In 2021, he joined ELAC SONAR GmbH, Kiel, Germany, as an Electrical Design Engineer for the development of hydroacoustic systems in the maritime sector.

Leve Freiwald obtained his B.Sc. and M.Sc. degrees in electrical and information engineering and management from Kiel University, Germany, in 2017 and 2019, respectively. He served as the project lead for the EXIST Transfer of Research funded project aerosense from 2020 to 2022. The project aimed to develop millimeter-wave radar sensors for particle flow measurements and other industrial applications. Since 2022, he is working as a start-up consultant at the Center for Entrepreneurship at Kiel University with a focus on high-tech and knowledge-based spin-offs.

Florian Vogelsang (Graduate Student Member, IEEE) was born in Hattingen, Germany in 1993. He received the B.Sc and M.Sc. degrees in electrical engineering and information technology from Ruhr University Bochum, Bochum, Germany in 2015 and 2017, respectively. He has been a Research Assistant with the Institute of Integrated Systems, Ruhr University Bochum, Bochum, Germany since 2018. His current research interests include wideband radar systems in the mm-wave and THz range, realized as monolithic microwave integrated circuits (MMICs) in silicon-germanium technologies.

Nils Pohl received the Dipl.-Ing. and Dr.Ing. degrees in electrical engineering from Ruhr University Bochum, Bochum, Germany, in 2005 and 2010, respectively. From 2006 to 2011, he was a Research Assistant with Ruhr University Bochum, where he was involved in integrated circuits for millimeter-wave (mm-wave) radar applications. In 2011, he became an Assistant Professor with Ruhr University Bochum. In 2013, he became the Head of the Department of mm-wave Radar and High Frequency Sensors with the Fraunhofer FHR, Wachtberg, Germany. In 2016, he became a Full Professor for Integrated Systems with Ruhr University Bochum. In parallel, he is head of the Research group for Integrated Radar Sensors at Fraunhofer FHR. He has authored or coauthored more than 200 scientific papers and has issued several patents. His current research interests include ultra-wideband mm-wave radar, design, and optimization of mm-wave integrated SiGe circuits and system concepts with frequencies up to 500 GHz and above, as well as frequency synthesis and antennas. Prof. Pohl is a member of IEEE, VDE, ITG, EUMA, and URSI. He was a co-recipient of the 2009 EEEfCom Innovation Award, and a recipient of the Karl-Arnold Award of the North Rhine-Westphalian Academy of Sciences, Humanities and the Arts in 2013 and the IEEE MTT Outstanding Young Engineer Award in 2018. In 2023, he has be co-recipient ot the Best Paper-Awards of IEEE Sensor Letters, APS Letters, and the German VDE ITG Award. Additionally, he was co-recipient of the best paper award at EUMIC 2012, best demo award at RWW 2015, and best student paper awards at RadarConf 2020, RWW 2021, and EUMIC 2021.

Michael Höft was born in Lübeck, Germany, in 1972. He received the Dipl.-Ing. degree in electrical engineering and the Dr.-Ing. degree from the Hamburg University of Technology, Hamburg, Germany, in 1997 and 2002, respectively. From 2002 to 2013, he joined the Communications Laboratory, European Technology Center, Panasonic Industrial Devices Europe GmbH, Lüneburg, Germany. There he was first a Research Engineer and then a Team Leader, where he had been engaged in the research and development of microwave circuitry and components, particularly filters for cellular radio communications. Then he was at the same organization from 2010 to 2013 a Group Leader for the research and development of sensor and network devices. Since October 2013, he is a Full Professor at the Kiel University, Kiel, Germany, in the Faculty of Engineering, where he heads the Chair for Microwave Engineering of the Institute of Electrical and Information Engineering. His research interests include active and passive microwave components, (sub-)millimeter-wave quasi-optical techniques and circuitry, microwave and field measurement techniques, microwave filters, microwave sensors, and magnetic field sensors as well as related applications. Dr. Höft is a member of the European Microwave Association (EuMA), the Association of German Engineers (VDI), a member of the German Institute of Electrical Engineers (VDE), and a Senior Member of the Institute of Electrical and Electronics Engineers (IEEE).

References

Braasch, K, Bruhn, D, Teplyuk, A, Freiwald, L, Durdaut, P, Vogelsang, F, Pohl, N and Höft, M (2023) Two fully integrated SiGe radar sensors for the detection of particle streams using dual-frequency measurements. In 20th European Radar Conference (EuRAD), 20-22 September 2023, Berlin: IEEE.CrossRefGoogle Scholar
European Parliament: Directive 2008/50/EC of the Europe (2008) Parliament and of the council of 21 May 2008 on ambient air quality and cleaner air for Europe. Croatia 029, 169212.Google Scholar
Teplyuk, A, Knöchel, R and Khlopov, G (2009) Aerosol particle sensor based on millimeter wave coherent radar with high spatial resolution. In IEEE MTT-S International Microwave Symposium Digest, Berlin: IEEE.CrossRefGoogle Scholar
Doviak, RJ, Zrnic, DS and Sirmans, DS (1979) Doppler weather radar. Proceedings of the IEEE 67(11), 15221553.CrossRefGoogle Scholar
Khlopov, G, Linkova, A, Voitovych, O and Cherniakov, M (2011) Double frequency sounding of rain using contact measurements. In 8th Europ. Radar Conf. (EuRAD), Manchester: IEEE.Google Scholar
Knöchel, R, Khlopov, G, Linkova, A, Teplyuk, A, Schünemann, K and Voitovych, O (2009) Double frequency sounding of volume scatterers. In Intern. Radar Symp. (IRS). Hamburg: DGON.Google Scholar
Reinhardt, A, Teplyuk, A, Knöchel, R and Höft, M (2018) Remote characterization of particle streams with a multistatic dual frequency millimeter-wave radar. IEEE Transactions on Microwave Theory and Techniques 66(12), 58255832.CrossRefGoogle Scholar
Skolnik, MI (2008) Radar Handbook. The McGraw-Hill Companies.Google Scholar
Goldhirsch, J (2001) Attenuation and backscatter from a derived two-dimensional duststorm model. IEEE Transactions on Antennas and Propagation 49(12), 17031711.CrossRefGoogle Scholar
Balanis, CA (2012) Advanced Engineering Electromagnetics. Wiley.Google Scholar
Ruck, GT, Barrick, DE, Stuart, WD and Krichbaum, CK (1970) Radar Cross Section Handbook. New York: Plenum Press.CrossRefGoogle Scholar
Chen, S, Nguyen, KN and Afsar, MN (2006) Complex dielectric permittivity measurements of glasses at millimeter waves and terahertz frequencies. In 2006 Europ. Microw. Conf., Manchester: IEEE.CrossRefGoogle Scholar
Heintzenberg, J (1994) Properties of the log-normal particle size distribution. Aerosol Science and Technology 21, 4648.CrossRefGoogle Scholar
Fang, Z, Patterson, BR and Turner, ME Jr. (1993) Modeling particle size distributions by the Weibull distribution function. Materials Characterization 31(3), 177182.CrossRefGoogle Scholar
Kueppers, S, Jaeschke, T, Pohl, N and Barowski, J (2022) Versatile 126–182 GHz UWB D-band FMCW radar for industrial and scientific applications. IEEE Sensors Letters 6(1), .CrossRefGoogle Scholar
Jaeschke, T, Bredendiek, C, Kueppers, S, Schulz, C, Baer, C and Pohl, N (2016) Cross-polarized multi-channel W-band radar for turbulent flow velocity measurements. In IEEE MTT-S Int. Microw. Symp., San Francisco: IEEE.CrossRefGoogle Scholar
Hansen, S, Kueppers, S and Pohl, N (2018) A wideband millimeter-wave SIW-to-RWG transition for thin single layer substrates with thick metal cladding. In 48th Europ. Microw. Conf. (EuMC), Madrid: IEEE.CrossRefGoogle Scholar
van de Hulst, HC (1981) Light Scattering by Small Particles. New York: Dover Publications Inc.Google Scholar
Rezende, RN (2019) Liquid Rocket Engine. SAE International.Google Scholar
Figure 0

Figure 1. Calculated monostatic RCS of a sphere depending on its radius in ratio to the signal wavelength.

Figure 1

Figure 2. Calculated monostatic DRCS for a constant frequency $f_1=90$ GHz and $f_2=160$ GHz. The blue area marks the area of unambiguity.

Figure 2

Figure 3. Calculated monostatic DRCS for a constant frequency $f_1=90$ GHz and various frequencies between $f_2=110$ GHz and $f_2=180$ GHz.

Figure 3

Figure 4. View of the fully integrated sensor of the (a) D-band and (b) W-band.

Figure 4

Figure 5. Simulated scattering pattern of one sphere when the radius is (a) inside the Rayleigh regime and (b) inside the Mie regime.

Figure 5

Figure 6. Schematic representation of the measurement setup.

Figure 6

Figure 7. Measurement setup with both radar sensors.

Figure 7

Figure 8. Directivity of the D-band horn antennas.

Figure 8

Figure 9. Directivity of the W-band horn antennas.

Figure 9

Table 1. Comparison of the two systems of the W-band and the D-band

Figure 10

Figure 10. SNR of the measurement with the W-band sensor.

Figure 11

Figure 11. SNR of the measurement with the D-band sensor.