Hostname: page-component-cd9895bd7-gxg78 Total loading time: 0 Render date: 2024-12-18T17:22:23.606Z Has data issue: false hasContentIssue false

Design of CPW-fed tapered MIMO antenna for ISM band applications

Published online by Cambridge University Press:  29 July 2015

Srimathi Mathialagan*
Affiliation:
Department of ECE, TSM Jain College of Technology, Melur, Kallakurichi, Villupuram-606201, India
*
Corresponding author: Srimathi Mathialagan Email: [email protected]

Abstract

In this paper, an implantable coplanar waveguide-fed tapered monopole antenna for industrial scientific and medical band (2.4–2.48 GHz) applications is proposed. This proposed design has an overall dimension of 44 × 44 × 0.5 mm3. The designed antenna is made compatible for implantation on human tissues such as skin, fat, or muscles by embedding it on the RT Duroid substrate and the 10 dB return loss bandwidth is 6.12% ranging from 2.35 to 2.5 GHz. This proposed antenna can be significantly used in implantable medical devices and radio frequency (RF), because of its merits such as conformability, flexibility in design and shape, biocompatibility, patient safety, miniaturization, power consumption, etc.

Type
Research Papers
Copyright
Copyright © Cambridge University Press and the European Microwave Association 2015 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

[1] Ashok Kumar, S.; Shanmuganantham, T.: Design and analysis of implantable CPW fed X-monopole antenna for ISM band applications. Telemed. e-Health, 20 (3) (2014), 246252.Google Scholar
[2] Huang, C.Y.; Yu, E.-Z.: A slot-monopole antenna for dual-band WLAN applications. IEEE Antennas Wireless Propag. Lett., 10 (2011), 500502.Google Scholar
[3] Ashok Kumar, S.; Shanmuganantham, T.: Analysis and design of implantable Z-monopole antennas at 2.45 GHz ISM band for biomedical applications. Microw. Opt. Technol. Lett., 57 (2) (2015), 468471.Google Scholar
[4] Bahl, I. J.: Lumped Elements for RF and Microwave Circuit. Artech House Microwave Library, Norwood, MA, 2003.Google Scholar
[5] Ashok Kumar, S.; Shanmuganantham, T.: Coplanar waveguide fed ISM band implantable crossed type triangular slot antenna for biomedical applications. Int. J. Microw. Wireless Technol., 6 (2) (2014), 167172.Google Scholar
[6] Ashok Kumar, S.; Shanmuganantham, T.: Implantable CPW Fed Monopole H-slot Antenna for 2.45 GHz ISM band Applications. Int. J. Electron. Commun., 68 (7) (2014), 661666.Google Scholar
[7] Sani, A.; Rajab, M.; Foster, R.; Hao, Y.: Antennas and propagation of implanted RFIDs for pervasive healthcare applications. Proc. IEEE, 98 (9) (2010), 16481655.Google Scholar
[8] Lee, C.M.; Yo, T.C.; Huand, F.J.; Luo, C.H.: Bandwidth enhancement of planar inverted-F antenna for implantable biotelemetry. Microw. Opt. Technol. Lett., 51 (2009), 749752.Google Scholar
[9] Ashok Kumar, S.; Shanmuganantham, T.: Design and analysis of implantable CPW fed bowtie antenna for ISM band applications. Int. J. Electron. Commun., 68 (2014), 158165.Google Scholar
[10] Wong, K.-L.: Compact and Broadband Microstrip Antennas, Wiley, New York, 2002.Google Scholar