Hostname: page-component-586b7cd67f-g8jcs Total loading time: 0 Render date: 2024-11-28T00:50:27.324Z Has data issue: false hasContentIssue false

Water Cultures Are More Sensitive Than Swab Cultures for the Detection of Environmental Legionella

Published online by Cambridge University Press:  27 November 2017

Brooke K. Decker*
Affiliation:
Infectious Diseases Section, Veterans Affairs Pittsburgh Healthcare System, Pittsburgh, Pennsylvania Department of Infectious Diseases, University of Pittsburgh, Pittsburgh, Pennsylvania
Patricia L. Harris
Affiliation:
Veterans Affairs Pittsburgh Healthcare System, Pittsburgh, Pennsylvania.
Diana L. Toy
Affiliation:
Veterans Affairs Pittsburgh Healthcare System, Pittsburgh, Pennsylvania.
Ali F. Sonel
Affiliation:
Department of Infectious Diseases, University of Pittsburgh, Pittsburgh, Pennsylvania
Cornelius J. Clancy
Affiliation:
Infectious Diseases Section, Veterans Affairs Pittsburgh Healthcare System, Pittsburgh, Pennsylvania Department of Infectious Diseases, University of Pittsburgh, Pittsburgh, Pennsylvania
*
Address correspondence to Brooke K. Decker, MD, Infectious Diseases Section, Veterans Affairs Pittsburgh Healthcare System, University Drive C, Pittsburgh, PA, 15240 ([email protected]).

Abstract

Water cultures were significantly more sensitive than concurrently collected swab cultures (n=2,147 each) in detecting Legionella pneumophila within a Veterans Affairs healthcare system. Sensitivity for water versus swab cultures was 90% versus 30% overall, 83% versus 48% during a nosocomial Legionnaires’ disease outbreak, and 93% versus 22% post outbreak.

Infect Control Hosp Epidemiol 2018;39:108–110

Type
Concise Communications
Copyright
© 2017 by The Society for Healthcare Epidemiology of America. All rights reserved 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

PREVIOUS PRESENTATION. This work was presented as a poster abstract (no. 642) at the Spring SHEA conference on May 20, 2016, in Atlanta, Georgia.

References

REFERENCES

1. Demirjian, A, Lucas, CE, Garrison, LE, et al. The importance of clinical surveillance in detecting Legionnaires’ disease outbreaks: a large outbreak in a hospital with a Legionella disinfection system—Pennsylvania, 2011–2012. Clin Infect Dis 2015;60:15961602.Google Scholar
2. Decker, BK, Harris, PL, Muder, RR, et al. Improving the diagnosis of Legionella pneumonia within a healthcare system through a systematic consultation and testing program. Ann Am Thorac Soc 2016;13:12891293.Google Scholar
3. Updated guidelines for the control of Legionella in western Pennsylvania. Allegheny County Health Department, Pittsburgh Regional Health Initiative. October 2014.Google Scholar
4. Sampling procedure and potential sampling sites. Centers for Disease Control and Prevention website. https://www.cdc.gov/legionella/downloads/cdc-sampling-procedure.pdf. Published 2015. Accessed July 20, 2017.Google Scholar
5. Wright, JB, Ruseska, I, Athar, MA, Corbett, S, Costerton, JW. Legionella pneumophila grows adherent to surfaces in vitro and in situ. Infect Control Hosp Epidemiol 1989;10:408415.Google Scholar
6. Hicks, L. The CDC investigation of Legionnaires’ disease among patients at the VA Pittsburgh Healthcare System. Centers for Disease Control and Prevention website. https://www.cdc.gov/washington/testimony/2013/t20130205.htm. Published 2013. Accessed October 27, 2017.Google Scholar
7. Kuroki, T, Watanabe, Y, Teranishi, H, Izumiyama, S, Amemura-Maekawa, J, Kura, F. Legionella prevalence and risk of legionellosis in Japanese households. Epidemiol Infect 2017;145:13981408.Google Scholar
8. Koziol-Montewka, M, Magrys, A, Stojek, N, et al. Monitoring Legionella species in hospital water systems. Link with disease and evaluation of different detection methods. Ann Agric Environ Med 2008;15:143147.Google ScholarPubMed
9. Ta, AC, Stout, JE, Yu, VL, Wagener, MM. Comparison of culture methods for monitoring Legionella species in hospital potable water systems and recommendations for standardization of such methods. J Clin Microbiol 1995;33:21182123.CrossRefGoogle ScholarPubMed