Utility of a Novel Reflective Marker Visualized by Flash Photography for Assessment of Personnel Contamination During Removal of Personal Protective Equipment

Published online by Cambridge University Press:  15 March 2016

Myreen E. Tomas
Affiliation:
Geriatric Research Education and Clinical Center, Cleveland Veterans Affairs Medical Center, 10701 East Boulevard, Cleveland, Ohio
Jennifer L. Cadnum
Affiliation:
Division of Infectious Diseases, Department of Medicine, Case Western Reserve University School of Medicine, Cleveland, Ohio
Thriveen S.C. Mana
Affiliation:
Division of Infectious Diseases, Department of Medicine, Case Western Reserve University School of Medicine, Cleveland, Ohio
Annette L. Jencson
Affiliation:
Research Service, Cleveland VA Medical Center, Cleveland, Ohio.
Sreelatha Koganti
Affiliation:
Research Service, Cleveland VA Medical Center, Cleveland, Ohio.
Heba Alhmidi
Affiliation:
Research Service, Cleveland VA Medical Center, Cleveland, Ohio.
Sirisha Kundrapu
Affiliation:
Division of Infectious Diseases, Department of Medicine, Case Western Reserve University School of Medicine, Cleveland, Ohio
Venkata C.K. Sunkesula
Affiliation:
Division of Infectious Diseases, Department of Medicine, Case Western Reserve University School of Medicine, Cleveland, Ohio
Curtis J. Donskey*
Affiliation:
Geriatric Research Education and Clinical Center, Cleveland Veterans Affairs Medical Center, 10701 East Boulevard, Cleveland, Ohio Division of Infectious Diseases, Department of Medicine, Case Western Reserve University School of Medicine, Cleveland, Ohio
*
Address correspondence to Curtis J. Donskey, MD, Geriatric Research, Education, and Clinical Center, Cleveland Veterans Affairs Medical Center, 10701 East Boulevard, Cleveland, Ohio 44106 ([email protected]).

Abstract

In an experimental study, the frequency of contamination of healthcare personnel during removal of contaminated personal protective equipment (PPE) was similar for bacteriophage MS2 and a novel reflective marker visualized using flash photography. The reflective marker could be a useful tool to visualize and document personnel contamination during PPE removal.

Infect Control Hosp Epidemiol 2016;37:711–713

Type
Concise Communications
Copyright
© 2016 by The Society for Healthcare Epidemiology of America. All rights reserved 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Tomas, ME, Kundrapu, S, Thota, P, et al. Contamination of healthcare personnel during removal of personal protective equipment. JAMA Intern Med 2015;175:19041910.Google Scholar
2. Zellmer, C, van Hoof, S, Safdar, N. Variation in health care worker removal of personal protective equipment. Am J Infect Control 2015;43:750751.CrossRefGoogle ScholarPubMed
3. Clay, KA, O’Shea, MK, Fletcher, T, et al. Use of an ultraviolet tracer in simulation training for the clinical management of Ebola virus disease. J Hosp Infect 2015;91:275277.CrossRefGoogle ScholarPubMed
4. Cassir, N, Boudjema, S, Roux, V, Reynier, P, Brouqui, P. Infectious diseases of high consequence and personal protective equipment: a didactic method to assess the risk of contamination. Infect Control Hosp Epidemiol 2015;36:14851486.Google Scholar
5. Tamimi, AH, Carlino, S, Edmonds, S, Gerba, CP. Impact of an alcohol-based hand sanitizer intervention on the spread of viruses in homes. Food Environ Virol 2014;6:140144.Google Scholar
6. Cohen, J. A coefficient of agreement for nominal scales. Educ Psychol Meas 1960;20:3746.Google Scholar
7. Landis, JR, Koch, GG. The measurement of observer agreement for categorical data. Biometrics 1977;33:159174.Google Scholar