Hostname: page-component-586b7cd67f-rcrh6 Total loading time: 0 Render date: 2024-11-28T03:16:31.217Z Has data issue: false hasContentIssue false

Reproducibility of cycle threshold values from severe acute respiratory coronavirus virus 2 (SARS-CoV-2) reverse-transcription polymerase chain reaction (RT-PCR) assays

Published online by Cambridge University Press:  16 December 2022

Ahad Azeem
Affiliation:
Division of Infectious Diseases, Department of Medicine, Creighton University School of Medicine, Omaha, Nebraska
Ryan W. Walters
Affiliation:
Department of Clinical Research and Public Health, Creighton University School of Medicine, Omaha, Nebraska
Stephen J. Cavalieri
Affiliation:
Department of Pathology, Creighton University School of Medicine, Omaha, Nebraska
David S. Quimby*
Affiliation:
Division of Infectious Diseases, Department of Medicine, Creighton University School of Medicine, Omaha, Nebraska
*
Author for correspondence: David S. Quimby, E-mail: [email protected]
Rights & Permissions [Opens in a new window]

Abstract

Type
Letter to the Editor
Copyright
© The Author(s), 2022. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America

To the Editor—To diagnose severe acute respiratory coronavirus virus 2 (SARS-CoV-2) infection, nucleic acid amplification is frequently used. Many such assays yield not only a detected or not detected result but also a cycle threshold (Ct) value. The Ct represents the cycle number needed to cross the positive (detected) signal threshold. This value is sometimes considered a surrogate for viral load because, in general, a lower Ct value suggests a higher viral concentration (and vice versa) in the specimen. Reference Salvatore, Dawson and Wadhwa1

Several proposals have been made for using Ct cutoffs to help determine the need for patient isolation. Reference Kapoor, Kalita and Panda2,Reference Tom and Mina3 However, before a test value can be used for clinical purposes, it must be determined to be reproducible; that is, similar results would be obtained regardless of the collector or across clinically insignificant time points. We sought to determine the reproducibility of Ct values to assess for discrepancy rates between sample collection variables and molecular assay performed.

The study was approved by the institutional review board (#infoEd record no. 2002107). We included patients aged >18 years who were inpatients at Creighton University Medical Center–Bergan Mercy (CUMC-BM) in Omaha, Nebraska, with a diagnosis of COVID-19 and a first positive PCR or antigen test for SARS-CoV-2 ≤5 days from the date of sampling. In total, 10 patients agreed to participate, and each underwent 4 nasal swabs. The first swab was performed by researcher A in the right naris (patient A0), and the second swab was performed by researcher B in the left naris (patient B0). After 10 minutes, 2 additional swabs were obtained: researcher A from the left naris (patient A10) and researcher B from the right naris (patient B10). The swabs were then stored at −80°C until all study swabs were collected.

Once collection was complete, swabs were processed at the CUMC-BM molecular laboratory. Samples were run on both the Abbott m2000 System (Abbott RealTime SARS-CoV-2 assay, dual target RdRp and N genes, Abbott Laboratories, Chicago, IL) and the LIASION MDX System (DiaSorin Molecular Simplexa COVID-19 Direct assay, dual target ORF1ab and S genes, Cypress, CA). The Ct values were recorded for each assay, with nondetectable values set to 40 cycles.

To account for the right censoring of Ct values at 40 cycles, we used a mixed-effects Tobit model that included a random intercept to account for the correlation due to repeated measurement of the same patient as well as fixed effects for the researcher collecting the specimen (A vs B), naris sampled (left vs right), time (0 vs 10), and assay (Abbott m2000 vs Simplexa S vs Simplexa ORF1ab). We used a top–down modeling approach that evaluated fixed interaction effects between researcher, naris sampled, time, and assay, and systematically removed nonstatistically significant interaction effects to arrive at the final model. All analyses were conducted using SAS version 9.4 software (SAS Institute, Cary, NC) with 2-tailed P < .05 indicating statistical significance.

The patient-specific Ct values are reported in Table 1. No statistically significant mean differences in Ct values were indicated between researchers A and B (22.9 vs 22.0; P = .055), left and right naris (22.2 vs 22.7, P = .346), or time 0 and time 10 (22.3 vs 22.7; P = .429). Although there was no overall mean difference between the 2 gene targets for the DiaSorin Molecular Simplexa S and ORF1ab assays (25.3 vs 25.8; P = .457), significant differences were observed between both DiaSorin Molecular Simplexa targets (S and ORF1ab; 25.3 vs 16.3; P < .001) and the Abbott RealTime SARS-CoV-2 assay (25.8 vs 16.3; P < .001).

Table 1. Cycle Threshold (Ct) Values by Patient, Researcher, Nares, and Time

Note. ND, nondetected (values for a system were set to 40).

a Patient number (1–10), researcher (A or B); naris and relative time of collection (time 0 or 10 minutes later; AO & B10-right naris; A10 and B0 left naris).

Our results are consistent with a study from College of American Pathologists, which urges discretion regarding the reliability of Ct values. Reference Rhoads, Peaper and She4 Rhoads et al Reference Rhoads, Peaper and She4 also reported significantly different values for Ct with standardized samples between platforms and even when the same platform was used at different laboratories. As an extreme example of result discrepancy, for patient 7 in our study, 2 of 4 swabs tested negative for both gene targets on the DiaSorin Molecular Simplexa assay, and 3 of the 4 swabs would still warrant ongoing patient isolation if the Abbott RealTime SARS-CoV-2 assay had been performed and an absolute Ct cutoff of 30 had been used to determine isolation need.

Singanayagam et al Reference Singanayagam, Patel and Charlett5 reported that 5 (8.3%) of 60 samples with a Ct >35 had culturable virus. Although a patient with culturable virus is not necessarily able to infect others, this is concerning if a single cutoff value is used to determine need for patient isolation. In our results, 5 (50%) of 10 patients had some swab values >30 and some <30, suggesting that determining isolation need based on such a cutoff would be swab variable and not based on any patient-specific factor. A more nuanced approach, such as that described by Mowrer et al Reference Mowrer, Creaker and Cawcutt6 in which Ct might play a role in conjunction with expert consultation and evaluation of clinical status, might be better if the Ct is to be used clinically. However, to use Ct in such a fashion, the Ct would need to be correlated with culturable virus for each platform in use at an institution because the absolute value of Ct is not reproducible between assays or even with the same assay between institutions. This is likely not possible for many clinical laboratories. We would therefore recommend caution if Ct is being considered for use for clinical or patient isolation purposes without such correlation having been performed.

Acknowledgments

Financial support

No financial support was provided relevant to this article.

Conflicts of interest

All authors report no conflicts of interest relevant to this article.

References

Salvatore, PP, Dawson, P, Wadhwa, A, et al. Epidemiological correlates of polymerase chain reaction cycle threshold values in the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Clin Infect Dis 2021;72:E761E767.Google ScholarPubMed
Kapoor, M, Kalita, D, Panda, PK. Cycle threshold values versus reverse transcription-polymerase chain reaction positivity in COVID-19 deisolation. Indian J Med Microbiol 2021;39:133135.Google ScholarPubMed
Tom, MR, Mina, MJ. To interpret the SARS-CoV-2 test, consider the cycle threshold value. Clin Infect Dis 2020;71:22522254.CrossRefGoogle ScholarPubMed
Rhoads, D, Peaper, DR, She, RC, et al. College of American Pathologists (CAP) Microbiology Committee Perspective: caution must be used in interpreting the cycle threshold (Ct) value. Clin Infect Dis 2021;72:E685E686.CrossRefGoogle ScholarPubMed
Singanayagam, A, Patel, M, Charlett, A, et al. Duration of infectiousness and correlation with RT-PCR cycle threshold values in cases of COVID-19, England, January to May 2020. Euro Surveill 2020;25:2001483.CrossRefGoogle ScholarPubMed
Mowrer, C, Creaker, H, Cawcutt, K, et al. Evaluation of cycle threshold values at deisolation. Infect Control Hosp Epidemiol 2022;43:794796.Google ScholarPubMed
Figure 0

Table 1. Cycle Threshold (Ct) Values by Patient, Researcher, Nares, and Time