Hostname: page-component-586b7cd67f-2plfb Total loading time: 0 Render date: 2024-11-28T06:39:56.783Z Has data issue: false hasContentIssue false

Measuring Rates of Hand Hygiene Adherence in the Intensive Care Setting: A Comparative Study of Direct Observation, Product Usage, and Electronic Counting Devices

Published online by Cambridge University Press:  02 January 2015

Alexandre R. Marra*
Affiliation:
Intensive Care Unit, Hospital Israelita Albert Einstein, São Paulo, Brazil
Denis Faria Moura Jr
Affiliation:
Intensive Care Unit, Hospital Israelita Albert Einstein, São Paulo, Brazil
Ângela Tavares Paes
Affiliation:
Statistics Department, Instituto Israelita de Ensino e Pesquisa, São Paulo, Brazil
Oscar Fernando Pavão dos Santos
Affiliation:
Intensive Care Unit, Hospital Israelita Albert Einstein, São Paulo, Brazil
Michael B. Edmond
Affiliation:
Department of Internal Medicine, Virginia Commonwealth University School of Medicine, Richmond
*
Hospital Israelita Albert Einstein, Avenida Albert Einstein, 627/701, Intensive Care Unit, 5th Floor, Morumbi, São Paulo, Brazil05651-901 ([email protected])

Abstract

Objective.

To compare 3 measures of hand hygiene adherence—direct observation, product usage, and electronic counting devices—in an intensive care unit.

Design.

A 12-week observational study.

Setting.

A 40-bed medical-surgical intensive care unit at a private tertiary care hospital.

Methods.

Over a 12-week period, we assessed hand hygiene adherence by 3 different methods: direct observation of practice, collection of data from electronic counters for dispensers of alcohol-based hand rub, and measurement of the amount of product used (alcohol-based hand rub and chlorhexidine).

Results.

There were 2,249 opportunities for hand hygiene observed, and the overall rate of hand hygiene adherence was 62.3% (representing 1,402 cleansing episodes). A total of 76,389 dispensing episodes were recorded by the electronic devices. The mean number of dispensing episodes per patient-day was 53.8. There was 64.1 mL of alcohol-based hand rub used per patient-day (representing 65.5% of total product used) and 33.8 mL of Chlorhexidine used per patient-day (representing 34.5%). There was no significant correlation between observed hand hygiene adherence and total product used per patient-day (r = 0.18; P = .59).

Conclusions.

Direct observation cannot be considered the gold standard for assessing hand hygiene, because there was no relationship between the observed adherence and the number of dispensing episodes or the volume of product used. Other means to monitor hand hygiene adherence, such as electronic devices and measurement of product usage, should be considered.

Type
Original Articles
Copyright
Copyright © The Society for Healthcare Epidemiology of America 2010

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Pittet, D, Mourouga, P, Perneger, TV. Compliance with handwashing in a teaching hospital. Ann Intern Med 1999;130:126130.Google Scholar
2.Boyce, JM, Pittet, D; Healthcare Infection Control Practices Advisory Committee; HICPAC/SHEA/APIC/IDSA Hand Hygiene Task Force. Guideline for hand hygiene in healthcare settings. Recommendations of the Healthcare Infection Control Practices Advisory Committee and the HIPAC/SHEA/APIC/IDSA Hand Hygiene Task Force. Am J Infect Control 2002;30:S1S46.Google Scholar
3.Marra, AR, Reis Guastelli, L, Pereira de Araújo, CM, et al.Positive deviance: a new strategy for improving hand hygiene compliance. Infect Control Hosp Epidemiol 2010;31:1220.Google Scholar
4.Pittet, D, Hugonnet, S, Harbarth, S, et al.Effectiveness of a hospital-wide programme to improve compliance with hand antisepsis. Lancet 2000;356:13071312.CrossRefGoogle Scholar
5.Bischoff, WE, Reynolds, TM, Sessler, CN, Edmond, MB, Wenzel, RP. Handwashing compliance by healthcare workers. The impact of introducing an accessible, alcohol-based hand antiseptic. Arch Intern Med 2000;160:10171021.Google Scholar
6.Berhe, M, Edmond, MB, Bearman, GM. Practices and an assessment of healthcare workers' perceptions of compliance with infection control knowledge of nosocomial infections. Am J Infect Control 2005;33:5557.CrossRefGoogle Scholar
7.World Health Organization (WHO). WHO guidelines on hand hygiene in heath care (advanced draft): a summary. Geneva, Switzerland: WHO, 2009.Google Scholar
8.Rupp, ME, Fitzgerald, T, Puumala, S, et al.Prospective, controlled, crossover trial of alcohol-based hand gel in critical care units. Infect Control Hosp Epidemiol 2008;29:815.Google Scholar
9.Kohli, E, Ptak, J, Smith, R, Taylor, E, Talbot, EA, Kirkland, KB. Variability in the Hawthorne effect with regard to hand hygiene performance in high- and low-performing inpatient care units. Infect Control Hosp Epidemiol 2009;30:222225.Google Scholar
10.Haas, JP, Larson, EL. Measurement of compliance with hand hygiene. J Hosp Infect 2007;66:614.Google Scholar
11.Boyce, JM, Cooper, T, Dolan, MJ. Evaluation of an electronic device for real-time measurement of alcohol-based hand rub use. Infect Control Hosp Epidemiol 2009;30:10901095.Google Scholar
12.Gould, DJ, Chudleigh, J, Drey, NS, Moralejo, D. Measuring handwashing performance in health service audits and research studies. J Hosp Infect 2007;66:109115.Google Scholar
13.Sax, H, Allegranzi, B, Uçkay, I, Larson, E, Boyce, J, Pittet, D. “My Five Moments for Hand Hygiene”: a user-centred design approach to understand, train, monitor, and report hand hygiene. J Hosp Infect 2007;67:921.Google Scholar
14.Kinsella, G, Thomas, AN, Taylor, RJ. Electronic surveillance of wall-mounted soap and alcohol gel dispensers in an intensive care unit. J Hosp Infect 2007;66:3439.Google Scholar
15.Scheithauer, S, Haefher, H, Schwanz, T, et al.Compliance with hand hygiene on surgical, medical, and neurologic intensive care units: direct observation versus calculated disinfectant usage. Am J Infect Control 2009;37:835841.Google Scholar
16.Novoa, AM, Pi-Sunyer, T, Sala, M, Molins, E, Castells, X. Evaluation of hand hygiene adherence in a tertiary hospital. Am J Infect Control 2007;35:676683.Google Scholar
17.Whitby, M, McLaws, ML, Slater, K, Tong, E, Johnson, B. Three successful interventions in healthcare workers that improve compliance with hand hygiene: is sustained replication possible? Am J Infect Control 2008;36:349355.CrossRefGoogle ScholarPubMed
18.Herud, T, Nilsen, RM, Svendheim, K, Harthug, S. Association between use of hand hygiene products and rates of healthcare-associated infections in a large university hospital in Norway. Am J Infect Control 2009;37:311317.Google Scholar