Hostname: page-component-586b7cd67f-l7hp2 Total loading time: 0 Render date: 2024-12-01T01:44:45.189Z Has data issue: false hasContentIssue false

Flash Sterilization: Carefully Measured Haste

Published online by Cambridge University Press:  02 January 2015

Dennis G. Maki*
Affiliation:
Infection Control Department, University of Wisconsin Hospital and Clinics, Madison, Wisconsin Section of Infectious Diseases, Department of Medicine, University of Wisconsin Medical School, Madison, Wisconsin
Carol A. Hassemer
Affiliation:
Infection Control Department, University of Wisconsin Hospital and Clinics, Madison, Wisconsin Section of Infectious Diseases, Department of Medicine, University of Wisconsin Medical School, Madison, Wisconsin
*
University of Wisconsin Hospital and Clinics, H41574, 600 Highland Avenue, Madison, WI 53792
Rights & Permissions [Opens in a new window]

Abstract

Image of the first page of this content. For PDF version, please use the ‘Save PDF’ preceeding this image.'
Type
Editorial
Copyright
Copyright © The Society for Healthcare Epidemiology of America 1987

References

1. Dandy, WE, The importance of more adequate sterilization processes in hospitals. Bull Am Coll Surg 1932;16:1114.Google Scholar
2. Bigelow, WD, Esty, JR, The thermal death-point in relation to time of typical thermophilic organisms. J Infect Dis 1920;27:602617.CrossRefGoogle Scholar
3. Williams, LB, The heat resistance of bacterial spores, J Infect Dis 1929;44:421465.CrossRefGoogle Scholar
4. Joint Commission on the Accreditation of Hospitals: Accreditation Manual for Hospitab—1986 Edition. Chicago, American Hospital Association, 1986, pp 7678.Google Scholar
5. Good Hospital Practice: Steam Sterilization and Sterility Assurance. Arlington, Association for the Advancement of Medical Instrumentation, 1980.Google Scholar
6. Ethylene Oxide Sterilization>: A Guide for Hospital Personnel. Arlington, Association for the Advancement of Medical Instrumentation, 1976.:+A+Guide+for+Hospital+Personnel.+Arlington,+Association+for+the+Advancement+of+Medical+Instrumentation,+1976.>Google Scholar
7. Good Hospital Practice: Steam Sterilization Using the Unwrapped Method (Flash Sterilization), September 1985 revision. Arlington, Association for the Advancement of Medical Instumentation, 1985.Google Scholar
8. Proposed recommended practices: Sterilization and disinfection. AORN J 1985;42:734754.CrossRefGoogle Scholar
9. Garner, JS, Favero, MS, Guideline for handwashing and hospital environmental control, 1985, in Guidelines for the Prevention and Control of Nosocomial Infections. Atlanta, Centers for Disease Control, Government Printing Office, 1985, pp 1013.Google Scholar
10. USP, The Pharmacopeia of the United States of America XX. US Pharmacopeial Convention, Rockville, MD, Mack Publishing Co, 1980.Google Scholar
11. Biological Indicators for Saturated Steam Sterilization Processes in Health Care Facilities. Arlington, Association for the Advancement of Medical Institutions, 1985.Google Scholar
12. Macek, TJ, Biological indicators. A USP review. Bull Patenter Drug Assoc 1972;26:1825.Google ScholarPubMed
13. Mayernick, JJ, Biological indicators for steam sterilization: A USP collaborative study. Bull Parenter Drug Assoc 1972;26:205211.Google Scholar
14. Gillis, JR, Biological indicators for steam sterilization process monitoring. Bull Parenter Drug Assoc 1975;29:111121.Google ScholarPubMed
15. Reich, RR, Influence of environmental storage relative humidity on biological indicator resistance, viability and moisture content. Appi Environ Microbiol 1982;43:609614.CrossRefGoogle ScholarPubMed
16. Hodges, NA, A comparison of heat resistance of commercially available B stearothermophilus spore preparations, J Pharm Pharmacol 1982;24:259260.Google Scholar
17. Maki, DG, Alvarado, C, Hassemer, C, False-positive results of spore tests in ethylene oxide sterilizers—Wisconsin. MMWR 1981;30:238240.Google Scholar
18. Epstein, BI, Lattimer, JM, Matsen, JM, et al: False-positive spore strip sterility tests with steam sterilization. Am J Infect Control 1983;11:7173.CrossRefGoogle ScholarPubMed
19. Anonymous: Sterilization? editorial. J Hosp Infect 1981;2:289290.CrossRefGoogle Scholar
20. Greene, VW, Control of sterilisation process, in Russell, AD, Hugo, WB, Ayliffe, GAJ (eds): Principles and Practice of Disinfection, Preservation and Sterilisation. Oxford, Blackwell Scientific Publications, 1982.Google Scholar
21. Joslyn, L, Sterilization by heat, in Black, SS (ed): Disinfection, Sterilization and Preservation, ed 3. Philadelphia, Lea and Febiger, 1983.Google Scholar
22. Gajdusek, DC, Gibbs, CJ, Asher, DM, et al: Precautions in medical care of, and in handling materials from, patients with transmissible virus dementia (Creutzfeldt-Jakob disease). N Engl J Med 1977;297:12531258.CrossRefGoogle ScholarPubMed
23. Sevitt, S, Source of two hospital-infected cases of tetanus. Lancet 1949;2:1075.CrossRefGoogle ScholarPubMed
24. Ho, JL, Highsmith, AK, Wong, ES, et al: Common-source Pseudomonas aeruginosa infection in neurosurgery. Proceedings and Abstracts of the Annual Meeting of the American Society for Microbiology. Washington, DC, American Society for Microbiology, 1981.Google Scholar
25. Perkins, JJ, Principles and Methods of Sterilization in Health Sciences, ed 2. Springfield, IL, Charles Thomas Publishers, 1969.Google Scholar
26. Maki, DG, Hassemer, C, Alvarado, C, Prospective study of the value of monitoring hospital sterilizers with biologic indicators. Proceedings and Abstracts of the 25th Inlerscience Conference on Antimicrobial Agents and Chemotherapy, Minneapolis. Washington, DC, American Society for Microbiology, 1985.Google Scholar
27. Underwood, WB, A Textbook of Sterilization, ed 2. Chicago, RR Donnelley and Sons Co, 1942, pp 9193.Google Scholar
28. Perkins, JJ, Bacteriological and surgical sterilization by heat, in Reddish, GF (ed): Antiseptics. Disinfectants, Fungicides and Chemical and Physical Sterilization. Philadelphia, Lea and Febiger, 1954, p 672.Google Scholar
29. Perkins, RE, Bodman, HA, Kundsin, RB, et al: Monitoringsteam sterilization of surgical instruments: A dilemma. Appi Environ Microbiol 1981;42(2:383384.CrossRefGoogle ScholarPubMed
30. Tornello, JD, Flash sterilization: Evaluating biological indicators. AORN J 1986;43:12891294.CrossRefGoogle ScholarPubMed
31. McCormick, PJ, Griffith, DB, Flash sterilization: Article creates controversy. AORN J 1986;44:908909.CrossRefGoogle Scholar
32. Reich, RR, Fitzpatrick, BG, Flash sterilization. J Hosp Supply Processing Distribution May/June 1985;6063.Google ScholarPubMed
33. Kotilainen, HR, Gantz, NM, An evaluation of three biological indicator systems in flash sterilization. Infect Control 1987;8:311316.CrossRefGoogle ScholarPubMed