Evaluation of Integrity of Gloves Used in a Flow Cytometry Laboratory

Published online by Cambridge University Press:  02 January 2015

Abstract

This study was conducted to evaluate the effect of normal use on latex glove integrity in a flow cytometry laboratory. The gloves were tested using the 1,000 μL watertight test and met industrial standards (less than 4% leakage) before, but not after, use. More durable gloves, or more frequent changes of gloves, may be needed to ensure adequate barrier protection for laboratory workers during routine procedures.

Type
Concise Communications
Copyright
Copyright © The Society for Healthcare Epidemiology of America 1997

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Rekus, JF. Bloodborne pathogens. Occup Health Saf 1991;60:3034.Google Scholar
2. Centers for Disease Control. Update: recommendations for prevention of HIV transmission in healthcare settings. MMWR 1987;254:30233161.Google Scholar
3. Kotilainen, HR, Brinker, JP, Avato, JL, Gantz, NM. Latex and vinyl examination gloves: quality control procedures and implications for health care workers. Arch Intern Med 1989;149:27492753.Google Scholar
4. Yangco, BG, Yangco, NF. What is leaky can be risky: a study of the integrity of hospital gloves. Infect Control Hosp Epidemiol 1989;10:553556.Google Scholar
5. US Department of Health and Human Services, Food and Drug Administration. Patient examination gloves and surgeons' gloves; sample plans and test method for leakage defects; adulteration. Federal Register December 12, 1990;55:5125451258. Guide 7124.31, Chapter 24—Devices. 1991:1-3.Google Scholar
6. Korniewicz, D, Laughon, B, Butz, A, Larson, E. Integrity of vinyl and latex procedure gloves. Nurs Res 1988;38:144146.Google Scholar
7. Korniewicz, D, Kirwin, M, Cresci, K, Markut, C, Larson, E. In-use comparison of latex gloves in two high risk units: surgical intensive care and acquired immunodeficiency syndrome. Heart Lung 1992;21:8184.Google Scholar
8. Klein, R, Party, E, Gershey, E. Safety in the laboratory. Nature 1989;341:288.Google Scholar
9. US Department of Health and Human Services, Food and Drug Administration; (21 CFR 800.20). Federal Register Chapter 1;993:710.Google Scholar