Effect of an External Urinary Collection Device on Catheter Associated Urinary Tract Infections in Hospitalized Women

Published online by Cambridge University Press:  02 November 2020

Lindsey Rearigh
Affiliation:
University of Nebraska Medical Center
Mark Rupp
Affiliation:
University of Nebraska Medical Center
Trevor Craig Van Schooneveld
Affiliation:
University of Nebraska Medical Center
Gayle Gillett
Affiliation:
Nebraska Medicine
Adrienne Sy
Affiliation:
Nebraska Medicine
Luana Evans
Affiliation:
Nebraska Medicine
Kelly Goetschkes
Affiliation:
Nebraska Medicine
Terry Micheels
Affiliation:
Nebraska Medicine
Elizabeth Lyden
Affiliation:
University of Nebraska Medical Center
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Background: Catheter-associated urinary tract infections (CAUTIs) are a common hospital-acquired infection (HAI) resulting in excess morbidity, mortality, and cost. Urine management can be a challenging issue, particularly in women, due to limited options for control of urinary incontinence. Issues with urinary leakage and worry for subsequent skin break down often leads to indwelling catheter insertion. In the spring of 2018, our facility implemented a female external urine collection device (EUCD) in efforts to decrease catheter days and to limit CAUTIs. Methods: Retrospective, 32-month (January 2017–August 2019), quasi-experimental, before-and-after study. Catheter use and CAUTI were defined according to CDC NHSN criteria. Poisson regression was used to model the rate of CAUTI (per 1,000 patient days [PD] and per 1,000 catheter days [CD]) comparing the 14 months prior to EUCD introduction with the 14 months after introduction and allowing a 3-month introduction period. Results: The CAUTI rate did not change significantly. The overall CAUTI rate per 1,000 PD decreased slightly from 0.24 to 0.20 (P = 0.44; model risk, 0.86; 95% CI, 0.58–1.26) whereas the rate per 1,000 CD increased slightly 1.5 to 1.6 (P = 0.76; model risk, 1.06; 95% CI, 0.73-–1.56). The CAUTI rate for men increased from 0.09 to 0.11 per 1,000 PD (P = 0.42; model risk, 1.29) and from 0.99 to 1.55 per 1,000 CD (P = 0.17; model risk, 1.56). For women, the rate of CAUTI decreased from 0.15 to 0.09 per 1,000 PD (P = 0.10; model risk, 0.61) and from 2.12 to 1.65 per 1,000 CD (P = 0.38; model risk, 0.38). A significant decrease in catheter days (CD per 1,000 PD; P < .0001) was observed for all hospitalized patients (from 158.56 to 128.3; model risk, 0.81), for men (from 87.06 to 72.15; model risk, 0.83), and for women (from 71.49 to 56.15; model risk, 0.79). Of 2,347 adverse events, 5 (0.2%) involved perineal skin breakdown and redness. Three events were related to malposition of the ECUD or inappropriate level of suction and 1 event was related to latex allergy and EUCD use. Conclusions: The introduction of a EUCD for women was associated with a significant decrease in indwelling catheter usage. A trend toward a decrease in CAUTI per 1,000 PD for women was observed (P = .10). Additional studies on whether the EUCD is associated with changes in UTI rates (both CAUTIs and noncatheter UTIs) as well as cost implications of EUCD are warranted.

Funding: None

Disclosures: None