Air contamination of households versus hospital inpatient rooms occupied by severe acute respiratory coronavirus virus 2 (SARS-CoV-2)–positive patients

Published online by Cambridge University Press:  04 February 2021

L. Silvia Munoz-Price*
Affiliation:
Division of Infectious Diseases, Department of Medicine, Medical College of Wisconsin, Milwaukee, Wisconsin
Frida Rivera
Affiliation:
Division of Infectious Diseases, Department of Medicine, Medical College of Wisconsin, Milwaukee, Wisconsin
Nathan Ledeboer
Affiliation:
Department of Pathology, Medical College of Wisconsin, Milwaukee, Wisconsin
*
Author for corrsepondence: L. Silvia Munoz-Price, E-mail: [email protected]
Rights & Permissions [Opens in a new window]

Abstract

The household setting has some of the highest coronavirus disease 2019 (COVID-19) secondary-attack rates. We compared the air contamination in hospital rooms versus households of COVID-19 patients. Inpatient air samples were only positive at 0.3 m from patients. Household air samples were positive even without a COVID-19 patient in the proximity to the air sampler.

Type
Concise Communication
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
© The Author(s), 2021. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America

Severe acute respiratory coronavirus virus 2 (SARS-CoV-2) is transmitted primarily by respiratory droplets and contact with contaminated surfaces and fomites. 1 Airborne transmission is still a controversial topic among the scientific community. A few studies have successfully identified SARS-CoV-2 in the air of hospital rooms using real-time reverse-transcriptase polymerase chain reaction (RT-PCR) or viral cultures. Reference Chia, Coleman and Tan2-Reference Binder, Alarja and Robie5 However, air contamination in households has yet to be characterized. The household setting has high secondary-attack rates, and members of the same household have been shown to experience up to 10 times greater risk of coronavirus disease 2019 (COVID-19) than other contacts (ie, healthcare workers, workplace contacts, and nonhousehold contacts). Reference Shah, Saxena and Mavalankar6-Reference Fung, Martinez and Alarid-Escudero8

Understanding the degree of air contamination in household settings would help us tailor prevention interventions in these high-risk settings. To address this knowledge gap, our study aimed to characterize and compare the presence of SARS-CoV-2 in air samples obtained in household settings against air samples obtained in inpatient rooms both selected based on the presence of SARS-CoV-2–positive patients.

Methods

This study was performed at Froedtert Memorial Lutheran Hospital, a 607-bed academic medical center affiliated with the Medical College of Wisconsin. This inpatient facility has 6 intensive care units (ICUs) with 150 ICU beds. During the pandemic, a few units were designated for cohorting SARS-CoV-2–positive patients, including the medical ICU, the cardiovascular ICU, and a couple of general medical-surgical units. All of these units were set for at least 6 air changes per hour and for negative pressure relative to the hallways.

A convenience sample of rooms was selected based on the presence of patients with positive SARS-CoV-2 RT-PCR tests. Households were identified based on the presence of at least 1 household member with symptoms compatible with COVID-19 and at least one positive SARS-CoV-2 RT-PCR test. All study participants had a positive SARS-CoV-2 test in the 7 days preceding air sampling.

Air sampling and molecular testing

Air samples were collected using the Sartorius MD8 airscan sampling device (SartoriusAG, Göttingen, Germany) with sterile gelatin filters (80 mm in diameter and 3 μm pore size (SartoriusAG). Briefly, the air sampler was positioned 0.305–1.83 m from the patient’s head to collect 1,000–4,000 L (50 L/minute). We evaluated shorter distances and higher volumes until we were able to detect SARS-CoV-2 in air samples. For samples that obtained 4,000 L, 2 air samplers were used concomitantly for 40 minutes (50 L/minute; 2,000 L each). Gelatin filters were placed in 6 mL viral transport media (VTM) (Remel M4RT, ThermoFisher, Lenexa, KS). If 2 air samplers were used concomitantly to achieve 4,000 L, then both gelatin membranes were placed in a single container with 6 mL VTM. These plates were incubated at 37oC for 1 minute to allow the gelatin filter to dissolve. This mixture was then spun in a vortex machine and centrifuged at 13,000×g for 1 minute, and 1 mL supernatant was used for nucleic acid extraction. Nucleic acid extraction and RT-PCR were performed on the Cobas 6800 (Roche, Indianapolis, IN) according to the manufacturer’s emergency use authorization (EUA)–approved product insert. For patient specimens, combined nasopharyngeal and oropharyngeal swabs were collected from each patient, and both the nasopharyngeal and oropharyngeal swabs were placed into 3 mL VTM (Copan, Murrieta, CA). RT-PCR was performed to detect the presence of SARS-CoV-2 on each sample using the Cobas 6800 according to the manufacturer’s EUA-approved product insert.

Results

We included 25 air samples from 15 inpatient rooms (16 samples) and 5 households (9 samples) where SARS-CoV-2–positive patients were housed (Table 1). Of 16 air samples from inpatient rooms, 2 (12.5%; 2 inpatient rooms) were SARS-CoV-2 positive, and of 9 household samples, 5 (55.5%; 3 households) had SARS-CoV-2 detected (odds ratio, 8.75; 95% confidence interval, 1.21–63.43; P = .058). All samples had cycle threshold levels >30.

Table 1. Presence of SARS-CoV-2 in Households and Inpatient Hospital Rooms Occupied by SARS-CoV-2 Positive Patients

Note. ICU, intensive care unit; NA, not applicable; RT-PCR, reverse-transcriptase polymerase chain reaction; CT, cycle threshold; BiPAP, bilevel positive airway pressure.

a No positive patient was present in the room.

Hospital air samples

Of 15 patient rooms sampled, 14 were located in COVID-19 units (5 in ICUs and 9 in general medicine wards) and 1 was located on a non–COVID-19 unit. All rooms were set to have at least 6 air changes per hour, with negative pressure relative to the hallway, and their median size was 260.1 m Reference Chia, Coleman and Tan2 (range, 89.2–260.1). Of 15 air samples, 7 sampled 1,000 L (range, 1.83–0.91 m from the patient), and all of these samples were SARS-CoV-2 negative. Moreover, 5 samples tested 2,000 L at 0.91 m from the patient (all SARS-CoV-2 negative), 2 samples tested 4,000 L at 0.91 m (all SARS-CoV-2 negative), and 2 patients were sampled using 4,000 L each at 0.30 m from the patient (both SARS-CoV-2 positive) (Table 1 and Supplementary Fig. 1 online). Reference Cheng, Wong and Chan9

Regarding the characteristics of the 15 inpatients housed within the rooms sampled: 5 (33%) had hypoxic respiratory failure, 4 (26.6%) had COVID-19 pneumonia, 3 (20%) had fever with respiratory symptoms, 2 (13.3%) were asymptomatic, and 1 (6.6%) had septic shock of unclear etiology (Table 1). Two-thirds of patients required oxygen support at the time of sampling: 2 (13.3%) were mechanically intubated, 2 (13.3%) were on bilevel positive airway pressure, 3 (20%) were on high-flow nasal cannulae, and 4 (26.6%) were on nasal cannulae. The median number of days from symptom onset to air sampling was 5 (range, 2.75–8.5). The median number of days from the last positive SARS-CoV-2 test to the day of air sampling was 1.5 (range, 1–3.75). The 2 patients occupying the rooms with positive air samples had mild severity of illness and were not on supplemental oxygen. Days from symptom onset to sampling were 5 (patient 14) and 3 (patient 15).

Household air samples

All 5 households had at least 1 symptomatic SARS-CoV-2–positive member at the time of sampling, and nonoe of these patients was on supplemental oxygen. All positive household members had respiratory symptoms at the time of air sampling. The median number of days from the last positive SARS-CoV-2 test to the day of air sampling was 3 (range, 2.5–5). Furthermore, 5 samples (55.5%) from 3 households were positive for SARS-CoV-2 (Supplementary Fig. 2 online). Only 1 household had air conditioning running (no. 20), and 3 households had opened windows or doors immediately prior to air sampling (nos. 16, 17, and 19). Anecdotally, most households felt warm and humid at the time of testing.

Discussion

In this study, household samples were 8 times more likely to test positive for SARS-CoV-2 than inpatient samples. Inpatient rooms only tested positive when the volume of air sampled was quadrupled and the distance between air samplers and patients was minimal. Thus, these positive results may represent contaminated respiratory droplets being expelled by patients rather than actual air contamination. Given that room ventilation (ie, air changes per hour) was the main difference between these settings, our findings may suggest that the degree of ventilation in a room is more important in determining the degree of air contamination than the acuity of illness that a SARS-CoV-2 patient may be experiencing. Previous studies have characterized the air contamination in inpatient areas with a wide range of findings between 1.3% and 63.2% Reference Chia, Coleman and Tan2-Reference Binder, Alarja and Robie5 ; however, the viability of the virus in air samples is still controversial. To the best of our knowledge, this is the first report of air contamination by SARS-CoV-2 within household settings.

Our study has several limitations. The sample size was small; we used convenience samples and did not perform viral cultures. Furthermore, we did not measure the temperature or humidity of the rooms, which are environmental variables that may potentially affect the viability of the virus. In addition, we obtained more air samples per household than per inpatient room; therefore, we increased the likelihood of detecting positive samples in households. Despite these limitations, our preliminary findings suggest that household settings may have high degree of air contamination, signaling a major impact of room ventilation on this outcome. Future studies should characterize the variables determining the degree of air contamination in households and explore innovative ways to ameliorate this problem, especially in crowded households without access to natural Please provide missing Acknowledgments text?ventilation.

Supplementary material

To view supplementary material for this article, please visit https://doi.org/10.1017/ice.2021.45

Acknowledgments

Financial support

No funding sources were used for this publication.

Conflicts of interest

All authors report no conflicts of interests related to this publication.

References

COVID-19 & IPC overview. Centers for Disease Control and Prevention website. https://www.cdc.gov/coronavirus/2019-ncov/hcp/non-us settings/overview/index.html#transmission. Accessed November 17, 2020.Google Scholar
Chia, PY, Coleman, KK, Tan, YK, et al. Detection of air and surface contamination by SARS-CoV-2 in hospital rooms of infected patients. Nat Commun 2020;11:2800.CrossRefGoogle ScholarPubMed
Santarpia, JL, Rivera, DN, Herrera, VL, et al. Aerosol and surface contamination of SARS-CoV-2 observed in quarantine and isolation care. Sci Rep 2020;10:13892.CrossRefGoogle ScholarPubMed
Zhou, J, Otter, JA, Price, JR, et al. Investigating SARS-CoV-2 surface and air contamination in an acute healthcare setting during the peak of the COVID-19 pandemic in London. Clin Infect Dis 2020. doi: 10.1093/cid/ciaa905.CrossRefGoogle Scholar
Binder, RA, Alarja, NA, Robie, ER, et al. Environmental and aerosolized severe acute respiratory syndrome coronavirus 2 among hospitalized coronavirus disease 2019 patients. J Infect Dis 2020;222:17981806.10.1093/infdis/jiaa575CrossRefGoogle ScholarPubMed
Shah, K, Saxena, D, Mavalankar, D. Secondary attack rate of COVID-19 in household contacts: systematic review. QJM 2020;113:841850.CrossRefGoogle ScholarPubMed
Lei, H, Xu, X, Xiao, S, Wu, X, Shu, Y. Household transmission of COVID-19—a systematic review and meta-analysis. J Infect 2020;81:979997.CrossRefGoogle ScholarPubMed
Fung, HF, Martinez, L, Alarid-Escudero, F, et al. The household secondary attack rate of SARS-CoV-2: a rapid review. Clin Infect Dis 2020. doi: 10.1093/cid/ciaa1558.CrossRefGoogle Scholar
Cheng, VC, Wong, SC, Chan, VW, et al. Air and environmental sampling for SARS-CoV-2 around hospitalized patients with coronavirus disease 2019 (COVID-19). Infect Control Hosp Epidemiol 2020;41:12581265.10.1017/ice.2020.282CrossRefGoogle Scholar
Figure 0

Table 1. Presence of SARS-CoV-2 in Households and Inpatient Hospital Rooms Occupied by SARS-CoV-2 Positive Patients

Supplementary material: File

Munoz-Price et al. supplementary material

Munoz-Price et al. supplementary material

Download Munoz-Price et al. supplementary material(File)
File 12.7 KB
Supplementary material: Image

Munoz-Price et al. supplementary material

Figure S1

Download Munoz-Price et al. supplementary material(Image)
Image 26.4 KB
Supplementary material: Image

Munoz-Price et al. supplementary material

Figure S2

Download Munoz-Price et al. supplementary material(Image)
Image 563.8 KB