Hostname: page-component-586b7cd67f-gb8f7 Total loading time: 0 Render date: 2024-12-02T21:14:34.112Z Has data issue: false hasContentIssue false

Rethinking Sterilization Practices: Evidence for Event-Related Outdating

Published online by Cambridge University Press:  02 January 2015

Joan Webster*
Affiliation:
Royal Brisbane and Royal Women's Hospitals, Herston, Queensland, Australia
Wendy Lloyd
Affiliation:
Central Sterilising Department, Royal Women's Hospital, Herston, Queensland, Australia
Ping Ho
Affiliation:
Central Sterilising Department, Royal Women's Hospital, Herston, Queensland, Australia
Christine Burridge
Affiliation:
Royal Brisbane and Royal Women's Hospitals, Herston, Queensland, Australia
Narelle George
Affiliation:
Division of Microbiology, Queensland Health Pathology Service, Royal Brisbane and Royal Women's Hospitals, Herston, Queensland, Australia
*
Research, Level 6, Ned Hanlon Building, Royal Brisbane and Royal Women's Hospitals, Butterfield Street, Herston, QLD 4029, Australia

Abstract

A prospective study was conducted during a 2-year period to evaluate the effectiveness of event-related outdating. Hospital-prepared sterilized items (n = 152) were shelved in wards and every 3 months, several articles were retrieved and microbiologically tested. During the 2-year period, all of the items tested were sterile.

Type
Concise Communications
Copyright
Copyright © The Society for Healthcare Epidemiology of America 2003

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Simmons, BP. CDC guidelines for the prevention and control of nosocomial infections: guideline for hospital environmental control. Am J Infect Control 1983;11:97120.CrossRefGoogle ScholarPubMed
2.Klapes, NA, Greene, VW, Langholz, AC, Hunstiger, C. Effect of long-term storage on sterile status of devices in surgical packs. Infect Control 1987;8:289293.CrossRefGoogle ScholarPubMed
3.Widmer, AF, Houston, A, Bollinger, E, Wenzel, RP. A new standard for sterility testing for autoclaved surgical trays. J Hosp Infect 1992;21:253260.CrossRefGoogle ScholarPubMed
4.Lamb, J, Foster, S, Henderson, E, Krulicki, W. Significant savings achieved by implementing event related outdating. Canadian Operating Room Nursing Journal 1996;14:1214.Google ScholarPubMed
5.Standards Australia. Australian Standard AS 4187: Cleaning, Disinfecting and Sterilizing Reusable Medical and Surgical Instruments and Equipment, and Maintenance of Associated Environments in Health Care Facilities, 2nd ed. Homebush: Standards Australia; 1998:56.Google Scholar
6.Association of Operating Room Nurses. Proposed recommended practices for sterilization in the practice setting. AORNJ 1994;60:109119.CrossRefGoogle Scholar
7.Chadwick, S. Event related outdating: a fairy tale comes true. Canadian Operating Room Nursing Journal 1994;12:2226.Google ScholarPubMed