Hostname: page-component-586b7cd67f-dlnhk Total loading time: 0 Render date: 2024-12-01T01:34:14.754Z Has data issue: false hasContentIssue false

Interrater Reliability of Surveillance for Ventilator-Associated Events and Pneumonia

Published online by Cambridge University Press:  08 November 2016

Meeta Prasad Kerlin*
Affiliation:
Department of Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania
William E. Trick
Affiliation:
Collaborative Research Unit, Cook County Health and Hospitals Systems, Chicago, Illinois
Deverick J. Anderson
Affiliation:
Duke Center for Healthcare Epidemiology, Duke University, Durham, North Carolina
Hilary M. Babcock
Affiliation:
Department of Medicine, Washington University School of Medicine, St. Louis, Missouri
Ebbing Lautenbach
Affiliation:
Department of Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania
Renaud Gueret
Affiliation:
Collaborative Research Unit, Cook County Health and Hospitals Systems, Chicago, Illinois
Michael Klompas
Affiliation:
Department of Population Medicine, Harvard Medical School and Harvard Pilgrim Healthcare Institute, Boston, Massachusetts Department of Medicine, Brigham and Women’s Hospital, Boston, Massachusetts
*
Address correspondence to Meeta Prasad Kerlin, Perelman School of Medicine at the University of Pennsylvania, 3600 Spruce St, Gibson 5011, Philadelphia, PA 19104 ([email protected]).

Abstract

OBJECTIVE

To compare interrater reliabilities for ventilator-associated event (VAE) surveillance, traditional ventilator-associated pneumonia (VAP) surveillance, and clinical diagnosis of VAP by intensivists.

DESIGN

A retrospective study nested within a prospective multicenter quality improvement study.

SETTING

Intensive care units (ICUs) within 5 hospitals of the Centers for Disease Control and Prevention Epicenters.

PATIENTS

Patients who underwent mechanical ventilation.

METHODS

We selected 150 charts for review, including all VAEs and traditionally defined VAPs identified during the primary study and randomly selected charts of patients without VAEs or VAPs. Each chart was independently reviewed by 2 research assistants (RAs) for VAEs, 2 hospital infection preventionists (IPs) for traditionally defined VAP, and 2 intensivists for any episodes of pulmonary deterioration. We calculated interrater agreement using κ estimates.

RESULTS

The 150 selected episodes spanned 2,500 ventilator days. In total, 93–96 VAEs were identified by RAs; 31–49 VAPs were identified by IPs, and 29–35 VAPs were diagnosed by intensivists. Interrater reliability between RAs for VAEs was high (κ, 0.71; 95% CI, 0.59–0.81). Agreement between IPs using traditional VAP criteria was slight (κ, 0.12; 95% CI, −0.05–0.29). Agreement between intensivists was slight regarding episodes of pulmonary deterioration (κ 0.22; 95% CI, 0.05–0.39) and was fair regarding whether episodes of deterioration were attributable to clinically defined VAP (κ, 0.34; 95% CI, 0.17–0.51). The clinical correlation between VAE surveillance and intensivists’ clinical assessments was poor.

CONCLUSIONS

Prospective surveillance using VAE criteria is more reliable than traditional VAP surveillance and clinical VAP diagnosis; the correlation between VAEs and clinically recognized pulmonary deterioration is poor.

Infect Control Hosp Epidemiol 2017;38:172–178

Type
Original Articles
Copyright
© 2016 by The Society for Healthcare Epidemiology of America. All rights reserved 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Safdar, N, Dezfulian, C, Collard, HR, Saint, S. Clinical and economic consequences of ventilator-associated pneumonia: a systematic review. Crit Care Med 2005;33:21842193.CrossRefGoogle ScholarPubMed
2. Klompas, M. Interobserver variability in ventilator-associated pneumonia surveillance. Am J Infect Control 2010;38:237239.Google Scholar
3. Stevens, JP, Kachniarz, B, Wright, SB, et al. When policy gets it right: variability in US hospitals’ diagnosis of ventilator-associated pneumonia. Crit Care Med 2014;42:497503.Google Scholar
4. Surveillance for Ventilator-Associated Events. Centers for Disease Control and Prevention website. http://www.cdc.gov/nhsn/acute-care-hospital/vae/index.html. Published 2015. Accessed March 31, 2016.Google Scholar
5. Klein Klouwenberg, PM, van Mourik, MS, Ong, DS, et al. Electronic implementation of a novel surveillance paradigm for ventilator-associated events: feasibility and validation. Am J Respir Cri. Care Med 2014;189:947955.Google Scholar
6. Mann, T, Ellsworth, J, Huda, N, et al. Building and validating a computerized algorithm for surveillance of ventilator-associated events. Infect Control Hosp Epidemiol 2015:15.Google Scholar
7. Klompas, M, Anderson, D, Trick, W, et al. The preventability of ventilator-associated events. The CDC Prevention Epicenters Wake Up and Breathe Collaborative. Am J Respir Crit Care Med 2015;191:292301.Google Scholar
8. Horan, TC, Andrus, M, Dudeck, MA. CDC/NHSN surveillance definition of health care–associated infection and criteria for specific types of infections in the acute care setting. Am J Infect Control 2008;36:309332.CrossRefGoogle ScholarPubMed
9. Magill, SS, Klompas, M, Balk, R, et al. Developing a new, national approach to surveillance for ventilator-associated events. Crit Care Med 2013;41:24672475.Google Scholar
10. Cohen, J. A coefficient of agreement for nominal scales. Educ Psychol Meas 1960;20:3746.Google Scholar
11. Landis, JR, Koch, GG. The measurement of observer agreement for categorical data. Biometrics 1977:159174.Google Scholar
12. Emori, TG, Edwards, JR, Culver, DH, et al. Accuracy of reporting nosocomial infections in intensive-care–unit patients to the National Nosocomial Infections Surveillance System: a pilot study. Infect Cont Hosp Ep 1998;19:308316.Google Scholar
13. Schurink, CA, Van Nieuwenhoven, CA, Jacobs, JA, et al. Clinical pulmonary infection score for ventilator-associated pneumonia: accuracy and inter-observer variability. Intens Care Med 2004;30:217224.Google Scholar
14. Tejerina, E, Esteban, A, Fernández-Segoviano, P, et al. Accuracy of clinical definitions of ventilator-associated pneumonia: comparison with autopsy findings. J Crit Care 2010;25:6268.Google Scholar