Bacteriological Monitoring of Water Reservoirs in Oxygen Humidifiers: Safety of Prolonged and Multipatient Use of Prefilled Disposable Oxygen Humidifier Bottles

Published online by Cambridge University Press:  21 June 2016

Nobuharu Kobayashi
Affiliation:
Department of Microbiology, Saitama Medical School, Moroyama, Iruma-gun, Saitama, Japan
Tsutomu Yamazaki*
Affiliation:
Department of Pediatrics, Saitama Medical School, Moroyama, Iruma-gun, Saitama, Japan Department of Infectious Diseases and Infection Control, Saitama Medical School, Moroyama, Iruma-gun, Saitama, Japan
Shigefumi Maesaki
Affiliation:
Department of Infectious Diseases and Infection Control, Saitama Medical School, Moroyama, Iruma-gun, Saitama, Japan
*
Department of Pediatrics, Saitama Medical School, Moroyama, Iruma-gun, Saitama 350-0495, Japan ([email protected])

Abstract

Bacterial colony counts in water specimens from oxygen humidifiers that used reusable water reservoirs were compared with counts in water specimens from humidifiers that used prefilled disposable reservoir bottles to evaluate the effects of prolonged and multipatient use of humidifiers. Bacteria were detected after 1 week of operation in water specimens collected from many humidifiers with reusable reservoirs, but no bacteria were detected in water specimens from disposable bottles for up to 12 weeks during use of the humidifier by multiple patients.

Type
Concise Communications
Copyright
Copyright © The Society for Healthcare Epidemiology of America 2006

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Gross, PA, Neu, HC, Aswapokee, P, Van Antwerpen, C, Aswapokee, N. Death for nosocomial infections; experience in a university hospital and a community hospital. Am J Med 1980; 68:219223.CrossRefGoogle Scholar
2.George, DL. Epidemiology of nosocomial ventilator-associated pneumonia. Infect Control Hosp Epidemiol 1993; 14:163169.CrossRefGoogle ScholarPubMed
3.Centers for Disease Control and Prevention. Guideline for prevention of nosocomial pneumonia. Respir Care 1994; 39:11911236.Google Scholar
4.Manangan, LP, Banerjee, SN, Jarvis, WR. Association between implementation of CDC recommendations and ventilator-associated pneumonia at selected US hospitals. Am J Infect Control 2000; 28:222227.CrossRefGoogle ScholarPubMed
5.Golar, SD, Sutherland, LL, Ford, GT. Multipatient use of prefilled disposable oxygen humidifiers up to 30 days: patient safety and cost analysis. Respir Care 1993; 38:343347.Google ScholarPubMed
6.Favero, MS, Carson, LA, Bond, WW, Petersen, NJ. Pseudomonas aeruginosa: growth in distilled water from hospital. Science 1971; 173:836838.CrossRefGoogle Scholar
7.Edwards, C. Problems posed by natural environments for monitoring microorganisms. Mol Biotechnol 2000; 15:211223.CrossRefGoogle ScholarPubMed
8.Bogosian, G, Aardema, ND, Bourneuf, EV, Morris, PJL, O'Neil, JP. Recovery of hydrogen-sensitive culturable cells of Vibrio vulnificus gives the appearance of resuscitation from a viable but nonculturable state. J Bacteriol 2000; 182:50705075.CrossRefGoogle Scholar
9.Koss, JA, Conine, TA, Eitzen, HE, LoSasso, AM. Bacterial contamination of sterile, prefilled humidifiers and nebulizer reservoirs. Heart Lung 1979; 8:11171121.Google ScholarPubMed
10.Henderson, E, Ledgerwood, D, Hope, KM, et al. Prolonged and multi-patient use of prefilled disposable oxygen humidifier bottles: safety and cost. Infect Control Hosp Epidemiol 1993; 14:463468.CrossRefGoogle Scholar
11.Seto, WH, Ching, TY, Yuen, KY, Lam, WK. Evaluating the sterility of disposable wall oxygen humidifiers, during and between use on patients. Infect Control Hosp Epidemiol 1990; 11:604605.CrossRefGoogle ScholarPubMed
12.Stoler, BS. Sterility of a disposable oxygen humidification system. Respir Care 1972; 17:572573.Google Scholar