Reply

Published online by Cambridge University Press:  01 August 2007

G. Gueret*
Affiliation:
Department of Anesthesiology and Surgical Intensive Care, University Hospital of Brest La Cavale Blanche, Brest, France
G. Kiss
Affiliation:
Department of Anesthesiology and Surgical Intensive Care, University Hospital of Brest La Cavale Blanche, Brest, France
R. Deredec
Affiliation:
Department of Anesthesiology and Surgical Intensive Care, University Hospital of Brest La Cavale Blanche, Brest, France
E. Bezon
Affiliation:
Department of Anesthesiology and Surgical Intensive Care, University Hospital of Brest La Cavale Blanche, Brest, France
J.-P. Warnier
Affiliation:
Department of Anesthesiology and Surgical Intensive Care, University Hospital of Brest La Cavale Blanche, Brest, France
A. Miossec
Affiliation:
Department of Anesthesiology and Surgical Intensive Care, University Hospital of Brest La Cavale Blanche, Brest, France
O. Corre
Affiliation:
Department of Anesthesiology and Surgical Intensive Care, University Hospital of Brest La Cavale Blanche, Brest, France
C. C. Arvieux
Affiliation:
Department of Anesthesiology and Surgical Intensive Care, University Hospital of Brest La Cavale Blanche, Brest, France
*
Correspondence to: Gildas Gueret, Department of Anesthesiology and Surgical Intensive Care, University Hospital of Brest La Cavale Blanche, Bd Tanguy Prigent, F-29609 Brest, France. E-mail: [email protected]; Tel: +33 2 98 34 72 88; Fax: +33 2 98 34 78 49

Abstract

Type
Correspondence
Copyright
Copyright © European Society of Anaesthesiology 2007

EDITOR:

We thank Dr Renner and colleagues for their interest in our article and their comments. We are grateful for all input into the discussion about our article on cardiac output monitoring during off-pump coronary artery bypass (OPCAB) surgery.

We agree with Dr Renner and colleagues that aortic transit-time ultrasound (ATTUS) cardiac output measurement is the true clinical gold standard for instantaneous cardiac output measurements. However, to our knowledge, in the case of OPCAB surgery, ATTUS has not yet been compared with other cardiac output measurement techniques. Indeed, continuous cardiac output measurements with either pulmonary artery catheter or partial CO2 rebreathing (PRCO) techniques do not provide continuous beat-to-beat assessment of cardiac output. Ideally, the best monitoring equipment should be non-invasive and beat-to-beat, and neither PRCO nor ATTUS achieve both of these ideals.

Concerning ventilation during OPCAB surgery, our anaesthetists only exceptionally have to decrease tidal volume below 10 mL kg−1 in order to adjust to the needs of the surgeons. End-tidal CO2 is maintained by adjusting respiratory rate. As we mentioned in our article, no changes in cardiac output readings were observed, suggesting that acute haemodynamic events recorded by either method were related to changes in ventilatory settings. The differences in attitudes of surgeons and between institutions towards tidal volume during OPCAB surgery might be the reason why we were not concerned about the theoretical link of low tidal volume and inadequate rebreathing under our operating conditions. In addition, as mentioned by Tachibana and colleagues [Reference Tachibana, Imanaka and Miyano1], the accuracy of the non-invasive cardiac output (NICO) technique can be maintained even at small tidal volumes if normocapnia is achieved by adjusting the respiratory rate. Conversely, the same authors also stated that the NICO underreports cardiac output at small tidal volumes. On the other hand, it is the variation of cardiac output which gives more information about acute haemodynamic changes than the absolute number itself. A disadvantage of underestimation of cardiac output could rather serve as an incentive to react quicker to haemodynamic changes. The assumption of a stable pulmonary capillary blood flow during NICO measurement cycles is indeed a drawback, and recalibration is needed in case of changes of SPO2 and FiO2.

We stated that the NICO showed a faster response than the pulmonary artery catheter during OPCAB surgery. In fact, this statement was based on observation and it is correct to add that it has not been substantiated by any of our data. Bein and colleagues [Reference Bein, Hanne and Hanss2] correctly concluded that NICO as compared to ATTUS is not suitable for cardiac output determination during quickly changing haemodynamic conditions applicable to their setting of aortic reconstruction. However, to our knowledge ATTUS has neither been examined nor brought into practice as a monitoring tool for OPCAB surgery. Therefore, in this context, even with a delayed response time of 165 s, NICO still remains an interesting monitoring option for OPCAB surgery [Reference Gueret, Kiss and Rossignol3].