Hostname: page-component-cd9895bd7-7cvxr Total loading time: 0 Render date: 2024-12-18T22:36:56.867Z Has data issue: false hasContentIssue false

Effects of pneumoperitoneum and reverse Trendelenburg position on cardiopulmonary function in morbidly obese patients receiving laparoscopic gastric banding

Published online by Cambridge University Press:  16 August 2006

A. Casati
Affiliation:
Department of Anaesthesiology, University of Milan, IRCCS H San Raffaele, Milan, Italy
L. Comotti
Affiliation:
Department of Anaesthesiology, University of Milan, IRCCS H San Raffaele, Milan, Italy
C. Tommasino
Affiliation:
Department of Anaesthesiology, University of Milan, IRCCS H San Raffaele, Milan, Italy
C. Leggieri
Affiliation:
Department of Anaesthesiology, University of Milan, IRCCS H San Raffaele, Milan, Italy
E. Bignami
Affiliation:
Department of Anaesthesiology, University of Milan, IRCCS H San Raffaele, Milan, Italy
F. Tarantino
Affiliation:
Department of Anaesthesiology, University of Milan, IRCCS H San Raffaele, Milan, Italy
G. Torri
Affiliation:
Department of Anaesthesiology, University of Milan, IRCCS H San Raffaele, Milan, Italy
Get access

Abstract

We prospectively evaluated the effects of pneumoperitoneum and reverse Trendelenburg position on cardiopulmonary function in 20 ASA physical status II–III morbidly obese patients (body mass index > 35 kg m−2) undergoing laparoscopic gastric banding. After general anaesthesia was induced, patients' lungs were ventilated using intermittent positive pressure ventilation (at measurement times, the following parameters were used: tidal volume 12 mL kg−1 ideal body weight, respiratory rate of 12 bpm, an inspiratory to expiratory time ratio of 1 : 2). Haemodynamic variables, blood gas parameters, and lung/chest compliance were recorded: in the supine position, after induction of general anaesthesia (T0, baseline) and induction of pneumoperitoneum (T1); after placing the patient in a 25° reverse Trendelenburg position (T2); during the surgical time (T3); before deflating the abdomen (T4); after pneumoperitoneum resolution (T5), and before the end of anaesthesia, with the patient supine (T6). The PaO2, PaO2/FiO2 ratio, and lung/chest compliance decreased during the study. After the pneumoperitoneum had been resolved, lung/chest compliance but not oxygenation parameters returned to baseline values. The arterial to end-tidal CO2 tension difference progressively increased from 0.38 ± 0.3 kPa (2.85 ± 2.25 mmHg) (T0) to 0.63 ± 0.3 kPa (4.73 ± 2.25 mmHg) (T6). In morbidly obese patients, undergoing laparoscopic gastric banding, a CO2 pneumoperitoneum markedly affected gas exchange and lung/chest compliance, while positioning the patient in a 25° reverse Trendelenburg position had no beneficial effects.

Type
Original Article
Copyright
2000 European Society of Anaesthesiology

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)