Hostname: page-component-586b7cd67f-t7fkt Total loading time: 0 Render date: 2024-11-23T11:29:16.778Z Has data issue: false hasContentIssue false

Transfer of Staphylococcus aureus via nurses' uniforms

Published online by Cambridge University Press:  15 May 2009

Anna Hambraeus
Affiliation:
Institute of Medical Microbiology, Department of Clinical Bacteriology, University of Uppsala, Sweden, and the Clinic of Plastic Surgery, Akademiska sjuhhuset, Uppsala, Sweden
Rights & Permissions [Opens in a new window]

Summary

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

The contamination of gowns and uniforms worn in a burns unit and the transfer of patient's staphylococci by means of nurses' uniforms was investigated. The median values of staphylococci found on gowns and jackets worn during a routine nursing procedure were 3·0 × 104 and 1·4 × 103 respectively. From the results of model nursing experiments it appeared as if the fraction of staphylococci transferred from a patient's room to the air in a receiving room was 4 to 10 times less when protective gowns were worn than when no gowns were worn. The corresponding transfer directly to the model ‘patient’ was 100 times less. The protection afforded by a gown seemed mainly to be due to protection against contamination of the uniform worn underneath when nursing a burned patient. The discrepancy between the transfer of an airborne particle tracer and Staph. aurats-carrying particles earlier found in the ward could be explained by the dispersal of Staph. aureus from nurses' clothing.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1973

References

REFERENCES

Anthony, B. F. & Wannamaker, L. W. (1967). Bacterial interference in experimental burns. Journal of Experimental Medicine 125, 319.CrossRefGoogle ScholarPubMed
Bernard, H. R., Cole, W. R. & Gravens, D. L. (1967). Reduction of iatrogenic bacterial contamination in operating rooms. American Journal of Surgery 165, 609.Google ScholarPubMed
Bethune, D. W., Blowers, R., Parker, M. & Pask, E. A. (1965). Dispersal of Staphylococcus aureus by patients and surgical staff. Lancet i, 480.CrossRefGoogle Scholar
Blair, J. E. & Williams, R. E. O. (1961). Phage-typing of staphylococci. Bulletin of the World Health Organization 24, 771.Google ScholarPubMed
Blowers, R. & Wallace, K. R. (1955). Sterilisation of blankets with cetyl trimethylamine bromide. Lancet i, 1250.CrossRefGoogle Scholar
Blowers, R. & McCluskey, M. (1965). Design of operating-room dress for surgeons. Lancet ii, 681.CrossRefGoogle Scholar
Charnley, J. & Eftekhar, N. (1968). Centre for Hip Surgery Wrightington Hospital, Internal Publication, no. 19.Google Scholar
Duguid, J. P. & Wallace, A. T. (1948). Air infection with dust liberated from clothing. Lancet ii, 845.CrossRefGoogle Scholar
Hall, L. B. & Hartnett, M. J. (1964). Measurement of the bacterial contamination on surfaces in hospitals. Public Health Reports, Washington 79, 1021.CrossRefGoogle ScholarPubMed
Hambraeus, A. (1973). Dispersal and transfer of Staph. aureus in an isolation ward for burned patients. Journal of Hygiene 71, 787.CrossRefGoogle Scholar
Hambraeus, A. & Sanderson, H. F. (1972). Studies with an airborne particle tracer in an isolation ward for burned patients. Journal of Hygiene 70, 299.CrossRefGoogle Scholar
Hare, R. & Thomas, C. G. A. (1956). The transmission of Staphylococcus aureus. British Medical Journal ii, 840.CrossRefGoogle Scholar
Lidwell, O. M. & Towers, A. G. (1972). Unidirectional (‘Laminar’) flow ventilation system for patient isolation. Lancet i, 347.CrossRefGoogle Scholar
Michaelsen, G. S., Halbert, M. M., Sorenson, S. D. & Vesley, D. (1968). Development of an open isolation system for the care of low resistance hospital patients. Report from the National Cancer Institute, National Institutes of Health, Department of Health, Education and Welfare.Google Scholar
Nicholes, P. S. (1970). Bacteria in laundered fabrics. American Journal of Public Health 60, 2175.CrossRefGoogle ScholarPubMed
Robinton, E. D. & Mood, E. W. (1968). A study of bacterial contaminants of cloth and paper towels. American Journal of Public Health 58, 1452.CrossRefGoogle ScholarPubMed
Di Salvo, J. W. (1958). Deoxyribonuclease and coagulase activity of micrococci. Medical Technicians Bulletin 9, 191.Google Scholar
Shinefield, H. R., Ribble, J. C., Boris, M. & Eichenwald, H. F. (1963). Preliminary observations on artificial colonization of newborns. American Journal of Diseases of Children 105, 146.Google Scholar
Speers, R., Shooter, R. A., Gaya, H., Patel, N. & Hewitt, J. H. (1969). Contamination of nurses' uniforms with Staphylococcus aureus. Lancet ii, 233.CrossRefGoogle Scholar
Sykes, G. (1970). The control of airborne contamination in sterile areas. Aerobiology, Proceedings of the Third International Symposium (ed. Silver, H. I.). London and New York: Academic Press.Google Scholar
Williams, R. E. O. & Shooter, R. A. (1963). Infections in Hospitals, Epidemiology and Control. Blackwell Scientific Publications, Oxford.Google Scholar