Hostname: page-component-586b7cd67f-g8jcs Total loading time: 0 Render date: 2024-11-24T13:33:29.209Z Has data issue: false hasContentIssue false

Transient complete atrioventricular block after percutaneous pulmonary valve implantation

Published online by Cambridge University Press:  20 August 2010

Bettina Ruf*
Affiliation:
Department of Pediatric Cardiology and Congenital Heart Disease, Deutsches Herzzentrum München, Technische Universität München, Munich, Germany
Andreas Eicken
Affiliation:
Department of Pediatric Cardiology and Congenital Heart Disease, Deutsches Herzzentrum München, Technische Universität München, Munich, Germany
John Hess
Affiliation:
Department of Pediatric Cardiology and Congenital Heart Disease, Deutsches Herzzentrum München, Technische Universität München, Munich, Germany
*
Correspondence to: B. Ruf, Department of Pediatric Cardiology and Congenital Heart Disease, Deutsches Herzzentrum München, Technische Universität München, Germany. Tel: 0049 891 218 3305; Fax: 0049 891 218 3333; E-mail: [email protected]

Abstract

Percutaneous pulmonary valve implantation for conduit dysfunction in the right ventricular outflow tract is a safe and efficient treatment in selected patients. We report on a patient with stenosis and regurgitation of a homograft in the right ventricular outflow tract who developed complete atrioventricular block during percutaneous implantation of a Melody™ valve. This complete atrioventricular block spontaneously reverted to a stable sinus rhythm after 3 weeks.

Type
Brief Reports
Copyright
Copyright © Cambridge University Press 2010

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Bonhoeffer, P, Boudjemline, Y, Saliba, Z, et al. Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction. Lancet 2000; 356: 14031405.CrossRefGoogle Scholar
2. Lurz, P, Coats, L, Khambadkone, S, et al. Percutaneous pulmonary valve implantation: impact of evolving technology and learning curve on clinical outcome. Circulation 2008; 117: 19641972.CrossRefGoogle ScholarPubMed
3. Nordmeyer, J, Khambadkone, S, Coats, L, et al. Risk stratification, systematic classification, and anticipatory management strategies for stent fracture after percutaneous pulmonary valve implantation. Circulation 2007; 115: 13921397.CrossRefGoogle ScholarPubMed
4. Nordmeyer, J, Coats, L, Lurz, P, et al. Percutaneous pulmonary valve-in-valve implantation: a successful treatment concept for early device failure. Eur Heart J 2008; 29: 810815.CrossRefGoogle ScholarPubMed
5. Sridharan, S, Coats, L, Khambadkone, S, Taylor, AM, Bonhoeffer, P. Images in cardiovascular medicine. Transcatheter right ventricular outflow tract intervention: the risk to the coronary circulation. Circulation 2006; 113: e934e935.CrossRefGoogle Scholar