Hostname: page-component-586b7cd67f-g8jcs Total loading time: 0 Render date: 2024-11-24T05:47:19.107Z Has data issue: false hasContentIssue false

Transcatheter closure of aortopulmonary window with Amplatzer duct occluder II: additional size

Published online by Cambridge University Press:  13 January 2020

Tayfun Uçar
Affiliation:
Department of Pediatric Cardiology, Medical School, Ankara University, Ankara, Turkey
Selen Karagözlü
Affiliation:
Department of Pediatric Cardiology, Medical School, Ankara University, Ankara, Turkey
Mehmet G. Ramoğlu*
Affiliation:
Department of Pediatric Cardiology, Medical School, Ankara University, Ankara, Turkey
Ercan Tutar
Affiliation:
Department of Pediatric Cardiology, Medical School, Ankara University, Ankara, Turkey
*
Author for correspondence: M. G. Ramoğlu, Ankara Üniversitesi Tıp Fakültesi Hastanesi, Tıp Fakültesi Caddesi, Cebeci/Çankaya, Ankara06590, Türkiye. Tel: +905327023611; Fax: +903123106371; E-mail: [email protected]

Abstract

Aortopulmonary window is a rare cardiac defect, and early management with surgery or transcatheter closure is lifesaving. Here, a 9-month-old patient, who underwent a successful device closure with additional size-Amplatzer duct occlude, is presented to make emphasis that it may be considered as the device of choice for defects in close proximity to aortic valve and/or coronary ostium.

Type
Brief Report
Copyright
© Cambridge University Press 2020

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Tiraboschi, R, Salomone, G, Crupi, G, et al.Aortopulmonary window in the first year of life: report on 11 surgical cases. Ann Thorac Surg 1988; 46: 438441.CrossRefGoogle ScholarPubMed
Atiq, M, Rashid, N, Kazmi, K, Qureshi, S. Closure of aortopulmonary window with amplatzer duct occluder device. Pediatr Cardiol 2003; 24: 298299.CrossRefGoogle ScholarPubMed
Li, X, Zhu, D, Feng, Y. Transcatheter closure of late-onset residual aortopulmonary septal defect using a muscular ventricular septal occluder. Int Heart J 2014; 55: 8991.CrossRefGoogle ScholarPubMed
Stamato, T, Benson, LN, Smallhorn, JF, Freedom, RM. Transcatheter closure of an aortopulmonary window with a modified double umbrella occluder system. Catheter Cardiovasc Diagnosis 1995; 35: 165167.CrossRefGoogle ScholarPubMed
Tulloh, R, Rigby, ML. Transcatheter umbrella closure of aorto-pulmonary window. Heart 1997; 77: 479480.CrossRefGoogle ScholarPubMed
Richens, T, Wilson, N. Amplatzer device closure of a residual aortopulmonary window. Catheter Cardiovasc Interv 2000; 50: 431433.3.0.CO;2-K>CrossRefGoogle ScholarPubMed
Sekar, RP, Shankar, PB, Cherian, KM. Transcatheter closure of a residual aortopulmonary window through internal jugular vein access. Indian Heart J 2012; 64: 521523.CrossRefGoogle Scholar
Alkhouli, M, Tarabishy, A, Kawsara, A, Alqahtani, F, Moiduddin, N. Transcatheter closure of a residual aortopulmonary window defect. J Card Surg 2017; 32: 206208.CrossRefGoogle ScholarPubMed
Odemis, E, Guvenc, O, Saygi, M, Demir, IH. Closure of aortopulmonary window using Nit‐Occlud® PDA‐R device in a 3‐month‐old infant. Pediatr Int 2016; 58: 754756.CrossRefGoogle Scholar