Hostname: page-component-78c5997874-v9fdk Total loading time: 0 Render date: 2024-11-16T09:21:03.846Z Has data issue: false hasContentIssue false

Lymphatic magnetic resonance imaging abnormalities in children with repaired tetralogy of Fallot

Published online by Cambridge University Press:  10 October 2024

Thomas Holm-Weber*
Affiliation:
Department of Thoracic Surgery, Rigshospitalet, Copenhagen, Denmark
Sheyanth Mohanakumar
Affiliation:
Department of Radiology, Aarhus University Hospital, Aarhus, Denmark
Thora Wesenberg Helt
Affiliation:
Department of Clinical Physiology & Nuclear Medicine, Rigshospitalet, Copenhagen, Denmark
Lotte Borgwardt
Affiliation:
Department of Diagnostic Radiology, Rigshospitalet, Copenhagen, Denmark
Lise Borgwardt
Affiliation:
Department of Clinical Physiology & Nuclear Medicine, Rigshospitalet, Copenhagen, Denmark
Klaus Juul
Affiliation:
Department of Pediatrics and Adolescent Medicine, Rigshospitalet, Copenhagen, Denmark
Vibeke B. Christensen
Affiliation:
Department of Pediatrics and Adolescent Medicine, Rigshospitalet, Copenhagen, Denmark Comparative Pediatrics and Nutrition, Copenhagen University, Copenhagen, Denmark
Vibeke E. Hjortdal
Affiliation:
Department of Thoracic Surgery, Rigshospitalet, Copenhagen, Denmark
*
Corresponding author: Thomas Holm-Weber; Email: [email protected]
Rights & Permissions [Opens in a new window]

Abstract

Introduction:

Tetralogy of Fallot patients face an elevated risk of developing chylothorax and pleural effusions post-surgery. This patient group exhibits risk factors known to compromise the lymphatic system, such as elevated central venous pressure, pulmonary flow changes, and hypoxia. This study investigates the morphology and function of the lymphatic system in tetralogy of Fallot patients through lymphatic magnetic resonance imaging and near-infrared fluorescence imaging, respectively.

Methods:

Post-repair tetralogy of Fallot patients aged 6–18 years were recruited, along with age and gender-matched controls. Magnetic resonance imaging was used to assess the morphology of the thoracic lymphatic vessels and the thoracic, while near-infrared fluorescence imaging was used to assess lymphatic activity utilising lymph rate, velocity, and pressure.

Results:

Nine patients and 10 controls were included. Echocardiography revealed that 2/3 of the patients had moderate-severe pulmonary regurgitation, while none displayed signs of elevated central venous pressure. Magnetic resonance imaging identified three patients with type 3 (out of 4 types) lymphatic abnormalities, while controls had none. The thoracic ducts showed severe (one patient) and moderate (one patient) tortuosity. Mean thoracic duct diameters were 3.3 mm ±1.1 in patients and 3.0 mm ± 0.8 in controls (p-value = 0.53). Near-infrared fluorescence imaging revealed no anomalous patterns.

Conclusion:

Despite no presence of clinical lymphatic disease, 3/9 of the repaired tetralogy of Fallot patients exhibited lymphatic morphological abnormalities. The significance of these anomalies remains uncertain currently. Further research is needed to determine whether these lymphatic alterations in this patient cohort are a result of congenital malformations, haemodynamic shifts, or prenatal and early-life saturation levels.

Type
Original Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2024. Published by Cambridge University Press

Introduction

Tetralogy of Fallot patients face higher risk than most congenital heart disease patients of developing chylothorax (4%) and pleural effusions (7%) after surgical repair. Reference Mavroudis, Mavroudis and Jacobs1,Reference Mouws, De Groot and Van De Woestijne2 Both conditions are severe comorbidities as they prolong intensive care unit stays. Reference Vaynblat, Chiavarelli, Anderson, Rao, Nudel and Cunningham3 The accumulated fluid during chylothorax contains fatty substances absorbed from the small intestines originating from the lacteals. This contrasts the accumulated fluid during serous pleural effusions, which contain serous fluid. Chylothorax fluid is characterised by a milky-white appearance, in contrast to the clear appearance of non-chylous pleural effusions. Chylothorax may be a result of traumatic injury during surgery, Reference Doerr, Allen, Nichols and Ryu4 whereas pleural effusions develop when the lymphatic system fails to reabsorb sufficient fluid. This can be instigated by various peri-surgical factors, such as alterations in haemodynamics, inflammation, preoperative oxygen levels, and the duration of mechanical ventilator use. Reference Biondi, Schulman, Wiedemann and Matthay5,Reference Talwar, Agarwala, Mittal, Choudhary and Airan6 Additionally, patients with tetralogy of Fallot live with elevated right atrial pressures, which are associated with the severity of the disease, higher mortality rates, Reference Egbe, Connolly, Miranda, Scott and Borlaug7 and compromises the lymphatic system’s ability to return lymphatic fluid to the central venous system. Reference Brace and Valenzuela8 While the haemodynamics in patients with tetralogy of Fallot is well described, Reference Bailliard and Anderson9 the lymphodynamics remain to be explored. Children diagnosed with tetralogy of Fallot manifest characteristics that can potentially impact the lymphatic system from the prenatal period till after the surgical repair. These manifestations include prenatal cyanosis, Reference Sun, van Amerom and Marini10 alterations in pulmonary blood flow, Reference Wise-Faberowski, Asija and McElhinney11 and elevated central venous pressures following the surgical repair. Reference Egbe, Connolly, Miranda, Scott and Borlaug7,Reference Egbe, Bonnichsen, Reddy, Anderson and Borlaug12 It is currently unclear whether paediatric patients with tetralogy of Fallot with no clinical lymphatic diseases exhibit abnormalities within their lymphatic system. This study aimed to examine if paediatric patients after surgical repair of tetralogy of Fallot have signs of subclinical abnormalities of the lymphatic system. To accomplish this, we evaluated lymphatic morphology and dynamics using two distinct methods: lymphatic MRI and near-infrared fluorescence imaging. Lymphatic MRI evaluates the morphology of lymphatic vessels, using a T2-weighted setting to capture the lymphatic vessels by detecting the signal from the slow or still standing fluid from within the lymphatic vessels. Whereas near-infrared fluorescence imaging offers real-time visualisation of lymphatic vessels, providing a dynamic and immediate assessment.

Materials and methods

Recruitment

Controls and patients who had undergone tetralogy of Fallot repair between 6 and 18 years of age were eligible to participate in this study, and 39 patient families were contacted (Figure 1 Supplementary). The healthy controls were recruited through the network of collaborators of the study. The patient records were reviewed to assess the surgical and medical history of the tetralogy of Fallot patients. To evaluate potential subclinical indicators of lymphatic disease, blood tests were drawn.

Figure 1. Tetralogy of Fallot.

Lymphatic MRI

The lymphatic anatomy of the neck (C2) to the diaphragm was acquired using a 1.5-T MRI system (GE Optima™ MR450w, GE Healthcare). The patient was placed supine, and multi-array radiofrequency coils were used. The lymphatic system was imaged using a procedure that involved coronal slices acquired with a respiratory-gated (navigator) 3-dimensional fast T2-weighted fast spin-echo sequence. This setting captures slow or still-standing fluid, enabling the investigator to detect the fluid within the lymphatic vessels. The typical imaging parameters were field of view 450 × 450 mm; pixel size, 1.1 × 1.1 × 1.0 mm; echo time, 700 ms; slice thickness, 2 mm.

Lymphatic near-infrared fluorescence imaging

The lymphatic activity was recorded using the Kaers Imaging System (Kaer Labs, Nantes, France.) Initially, indocyanine green was injected into the first and fourth interdigital spaces. The injected dye underwent excitation through a laser, triggering the emission of light upon the dye’s subsequent stabilisation. This emitted light was then captured by a custom-made camera, enabling the investigator to identify the lymphatic vessels. After 15 min of lying down, the lymph rate and velocity were measured (sequence 1), followed by the measurement of lymph pressure (sequence 2), and finally, the lymph rate and velocity 2 were obtained (sequence 3) (Figure 2 Supplementary).

Figure 2. Tetralogy of Fallot.

Lymph pressure was determined by occluding lymphatic flow using a Hokanson sphygmomanometer cuff (ADInstruments, Oxford, UK) after manually emptying the lymph vessels. The procedure involved placing a tourniquet on the calf, manually removing the dye by compressing the lymphatic vessels, inflating the cuff to 80 mmHg, and gradually reducing cuff pressure by 10 mmHg every fifth minute until the highest pressure at which the fluorescent dye passed the inflatable cuff was recorded as the lymph pressure.

Echocardiography

Standard echocardiographic measurements were performed by a single echocardiographer (KJ). The central venous pressure was estimated and grouped as: normal (5 mmHg), mildly increased (5–10 mmHg), moderately increased (10–15 mmHg), and severely increased (>15 mmHg). These estimates were determined based on the dilation of the inferior vena cava compared to the abdominal aorta, which could be non-dilated with inspiratory collapse, non-dilated with reduced inspiratory collapse, dilated with some inspiratory collapse, or dilated with no inspiratory collapse, respectively. Z-scores for tricuspid annular plane systolic excursion were calculated using the Boston Children’s Hospital reference material (https://zscore.chboston.org/).

Data analysis

Lymphatic MRI

The MRI sequences were analysed using Horos™ (Horos Project, Geneva, Switzerland). Three parameters were used to assess the lymphatic vessels.

Lymphatic abnormality score

The classification system proposed by Biko et al. was employed to evaluate the lymphatic abnormality in pre-Fontan patients. The scores range from 1 to 4. Reference Biko, DeWitt and Pinto13 Type 1 is interpreted as showing minimal or no presumed lymphatic channels within both the supraclavicular region and mediastinum (Figure 3.1 Supplementary). Type 2 exhibits abnormal elevation in lymphatic channels, specifically within the supraclavicular region, without any extension into the mediastinum (Fig 3.2 Supplementary). Type 3 displays abnormal supraclavicular lymphatics, with evident extension into the mediastinum (Fig 3.3 Supplementary). Type 4 displays abnormal supraclavicular lymphatic vessels extending into both the mediastinum and the lung parenchyma. Type 4 was associated with poorer outcomes after Fontan completion. The analysis was carried out by two investigators (TH and SM). In instances where there were discordant scores between the investigators, the sequences were reevaluated, and a final score was reached through mutual consensus.

Thoracic duct

The thoracic duct was assessed by tortuosity and diameter following the same approach as Castellanos et al. Reference Castellanos, Ahmad and St. Clair14 Thoracic duct tortuosity was determined using the following criteria: none, no turns or deviations; mild, one turn or subtle turns; moderate, multiple large turns or several small turns; and severe, turns along almost the entire course. The maximum diameter of the thoracic duct was ascertained by locating its largest segment in the coronal plane and then measuring it using a short-axis view.

Lymphatic near-infrared imaging

Lymphatic near-infrared imaging was solely utilised in the tetralogy of Fallot group to extract lymph rate, velocity, and pressure. Reference Holm-Weber, Kristensen, Mohanakumar and Hjortdal15– Reference Kelly, Mohanakumar, Telinius, Alstrup, Alstrup and Hjortdal17 Lymph rate and velocity were extracted using a custom LabView program (National Instruments, TX, U.S.). Lymph rate was determined as the number of lymphatic contractions generated per vessel per min, with analysis of all visible vessels and pooling of the mean contraction rate for each sequence. Lymph velocity was determined by measuring the velocity of lymph propulsion in cm/s.

ImageJ 18 was used to determine lymph pressure; the lymph pressure was defined as the maximum pressure the lymphatic vessels could overcome in mmHg following the same procedure as prior studies. Reference Holm-Weber, Kristensen, Mohanakumar and Hjortdal15,Reference Mohanakumar, Telinius and Kelly16,Reference Mohanakumar, Kelly and Turquetto19

Statistical analyses

Continuous variables are presented with means and standard deviations, while categorical variables are presented as frequencies. Student t-test was used to compare the tetralogy of Fallot participants to controls and non-participants. All statistical analyses were performed using R Core Team (2022). (R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria. URL https://www.R-project.org/).

Results

Study population

Nine out of the 39 invited patients accepted to participate in the study after parental consent was obtained. The baseline characteristics of both the control (age 11 ± 3 years, 50% female) and patient (age 12 ± 4 years, 44% female) groups are presented in (Supplementary Table 1). All examinations of each participant were conducted within 2 days, except for patient H, where the echocardiography was performed 1 month after the lymphatic MRI. All 9 patients have had pulmonary regurgitation at some time during their lives and the years exposed to pulmonary regurgitation varied from 2 to 15.5 years (Table 1) The examinations were conducted, on average, 11.6 ± 4 years following tetralogy of Fallot repair. Seven out of nine patients underwent transannular patch repair. Except for one patient diagnosed with DiGeorge syndrome (patient C), no other relevant comorbidities were identified within the patient group. Echocardiography revealed 5 of the 9 patients with tetralogy of Fallot exhibited severe pulmonary regurgitation at the time of investigation, while none displayed signs of elevated central venous pressure. (Supplementary Table 2) The invited tetralogy of Fallot patients who chose not to participate in the study had similar characteristics regarding age, sex, body size, or surgical history. (Supplementary Table 3) Data from the medical records showed that following tetralogy of Fallot repair, one patient had an extended stay in the intensive care unit due to right ventricle failure, while two patients experienced prolonged pleural effusion. Two patients had a valved conduit as the primary repair. Three patients were later revalved, one patient shortly after primary repair, and two patients during adolescence. No patients experienced chylothorax, oedema, protein-losing enteropathy, or ascites. Blood tests drawn during this study revealed no severely abnormal findings in either group (Supplementary Table 4,5).

Table 1. Surgical history and MRI findings of the tetralogy of Fallot patients

Age in years. Sex: F = female, M = male. Pre repair: ToF= tetralogy of Fallot; PA = pulmonary atresia; MAPCA = major aortopulmonary collateral arteries; Sat = saturations before repair; Shunted = number of months with palliative mBTT shunt. Repair: Age = months old at surgical repair; Repair = type of surgical repair; TAP = transannular patch. Post repair: Revalved = revalved after primary repair; PR = years with pulmonary regurgitation. MRI findings: Type: lymphatic MRI scoring according to Biko et al. Reference Biko, DeWitt and Pinto13 Tortousity = tortousity of the thoracic duct; ø = diameter of the thoracic duct (mm). One patient (C) had DiGeorge syndrome; the rest of the patients had no record of genetic disorders. Two patients (C + E) experienced prolonged pleural effusions. No additional history or current evidence of lymphatic disorders was revealed. NA = not available.

Lymphatic MRI and near-infrared fluorescence imaging

MRI revealed three patients with type 3 lymphatic abnormalities in the patient group versus none in the control group (Figure 1, 2). The thoracic ducts were moderately tortuous in another patient (patient B) and severely tortuous in one patient (patient G). No controls displayed severe or moderate thoracic duct tortuosity (Table 1). The mean thoracic duct diameters were 3.3 mm ± 1.1 and 3.0 mm ± 0.8 (p-value = 0.53) in the tetralogy of Fallot and control groups, respectively. The near-infrared fluorescence imaging investigations did not reveal any anomalous patterns (Supplementary Table 6).

Type 3 abnormal lymphatic vessels

The average duration between repair and lymphatic MRI was 11 years for patients exhibiting type 3 abnormal lymphatic vessels. Prior to repair, two out of three patients had low pre-repair saturations (Table 1). Moreover, within this specific subgroup, two patients (B and I) encountered complex trajectories both preceding and following the reparative interventions. Patients B and I underwent the application of the Blalock–Thomas–Taussig shunt palliation before repair. The Blalock–Thomas–Taussig shunt in patient B was subsequently replaced with another shunt before undergoing contegra graft repair, accompanied by subsequent dilations of the pulmonary arteries. On the other hand, patient G did not experience any significant surgical complications and received transannular patch repair. Patient I underwent placement of two Blalock–Thomas–Taussig shunts concurrently prior to the transannular patch repair. Patients G and I had severe pulmonary regurgitation at the time of the study. None of the patients had any symptoms of on-going lymphatic disease at the time of investigation or previously.

Discussion

We found abnormal lymphatic vessels (lymphatic MRI type 3) in three out of nine paediatric patients with tetralogy of Fallot, indicating some degree of lymphatic congestion. This is the first study to investigate the lymphatic state of children with tetralogy of Fallot using MRI and near-infrared fluorescence imaging.

Lymphatic congestion and pleural effusion in tetralogy of Fallot

The elevated central venous pressure observed in patients with tetralogy of Fallot Reference Egbe, Connolly, Miranda, Scott and Borlaug7 is a common risk factor for both lymphatic congestion Reference Witte, Dumont, Clauss, Rader, Levine and Breed20 and pleural effusions. Reference Vaynblat, Chiavarelli, Anderson, Rao, Nudel and Cunningham3 The fluid accumulation seen in pleural effusions is the result of an imbalance between fluid filtration and removal by the lymphatic system. Patients with tetralogy of Fallot undergoing repair surgery may exhibit three risk factors (elevated central venous pressure, increases in pulmonary blood flow, and reduced pre-repair oxygen saturation levels) that may be associated with the development of lymphatic congestion and/or pleural effusion.

Haemodynamics

Increased central venous pressure

The increased risk of pleural effusions following tetralogy of Fallot repair Reference Mavroudis, Mavroudis and Jacobs1 might be caused by restrictive right ventricle physiology. Restrictive right ventricle physiology increases the venous systemic pressure. Reference Cullen, Shore and Redington21 Increases in central venous pressure are known to impede the lymphatic system’s ability to return lymphatic fluid to the venous system. Reference Brace and Valenzuela8 In patients with Fontan circulation, central venous pressure is believed to be a main component of the pathophysiology, leading to an increase in afterload on the lymphatic system and lymphatic congestion. Reference Rychik, Atz and Celermajer22 This is thought to be the cause of a depressed lymphatic capacity in patients with Fontan circulation. Reference Mohanakumar, Kelly and Turquetto19 These patients are at risk of developing lymphatic disorders like protein-losing enteropathy, chylothorax, ascites, and plastic bronchitis. Reference Rychik, Atz and Celermajer22 However, severe lymphatic issues are rare in tetralogy of Fallot patients and have only been observed in case studies. Reference Brogan, Finn and Pyskaty23,Reference Mallula, Kenny and Hijazi24 None of our patients showed echocardiographic signs of elevated central venous pressure. However, during various stages of their surgical history leading up to valve replacement, there might have been periods when their central venous pressure was elevated. Each of our patients encountered some level of pulmonary regurgitation at some point in their lives, and at the time of this study, 2/3 of the patients continued to experience pulmonary regurgitation. Additionally, among patients with type 3 abnormal lymphatic vessels observed on MRI, two out of three had severe pulmonary regurgitation. (Supplementary Table 2).

Increased pulmonary flow

Ovine studies found that increases in pulmonary blood flow lead to impaired lymphatic drainage, dilation of lymphatic vessels, and increases in fluid filtration. Reference Datar, Johnson and Oishi25,26 The increases in pulmonary blood flow in shunt palliated tetralogy of Fallot patients pre-repair and all tetralogy of Fallot patients after repair (compared to before repair) could contribute to the lymphatic congestion. In the tetralogy of Fallot group with type 3 lymphatic abnormalities, two out of three were shunt palliated up until repair (Table 2).

Table 2. Characteristics of the three tetralogy of Fallot patients exhibiting lymphatic MRI type 3 abnormal lymphatics concerning pre-repair, repair, and post-repair periods

ToF = tetralogy of Fallot, PA = pulmonary atresia, Sat = saturations before repair, Shunted = months of systemic–pulmonary shunting, Age = age in months at repair; TAP = transannular patch; PR = pulmonary regurgitation in years; ø = thoracic duct diameter (mm).

Hypoxia

During hypoxia, the extravasation increases, leading to an increase in lymph production and reabsorption. Reference Raj, Hazinski and Bland27,Reference Hansen, Haberkern, Hazinski and Bland28 Furthermore, basic research and animal models suggest that lymphangiogenesis is stimulated during hypoxia. Reference Boehme, Morris and Chiacchia29,Reference Morfoisse, Renaud, Hantelys, Prats and Garmy-Susini30 Most patients with tetralogy of Fallot are exposed to varying degrees of hypoxia before surgical repair. Even before birth, patients with tetralogy of Fallot are exposed to lower saturation levels. Reference Sun, van Amerom and Marini10 These factors could also contribute to the development of abnormal lymphatic vessels compared with healthy controls. Two out of three in the tetralogy of Fallot group with type 3 lymphatic abnormalities had low systemic pre-repair saturations (Table 2).

Type 3 abnormal vessels

The group of patients with tetralogy of Fallot with type 3 abnormal vessels exhibited complex peri-surgical histories, severe pulmonary regurgitations, lower pre-repair saturations, and had been palliated with Blalock–Thomas–Taussig shunts (Table 2, Supplementary Table 2). All of which could potentially put a strain on the lymphatic system. The mean time from repair to lymphatic MRI was no different from the rest of the group, suggesting no time-associated factors within the study. The absence of previous or present clinical signs of lymphatic congestion underlines the subclinical nature of the findings and is aligned with Biko et al’s findings that Fontan patients only reported poorer outcome within the group with type 4 abnormalities.

Clinical impact

Currently, the clinical significance of the reported MRI findings indicating lymphatic congestion remains uncertain. In Fontan patients, lymphatic abnormalities are documented from infancy and seem to be associated with worse long-term outcomes. Reference Kristensen, Kelly, Kim, Dori and Hjortdal31 In patients with tetralogy of Fallot, an anomalous lymphatic system could potentially be a part of the explanation as to why they face an increased risk of developing post-repair pleural effusion.

Limitations

The limited sample size and cross-sectional design prevent us from making definitive conclusions regarding the underlying pathophysiology of this observation. Additionally, it is important to note that near-infrared fluorescence imaging investigations exclusively visualise superficial lymphatic vessels, while deeper vessels may exhibit distinct characteristics. The lymphatic MRI has limitations, particularly in its inability to capture flow patterns, compared to the more invasive dynamic lymphatic MRI. Additionally, it is worth noting that our study lacked pre-repair MRI images for the patient group, further contributing to the range of limitations. Furthermore, the MRI evaluation of abnormal lymphatic vessels utilised scoring systems originally developed to assess lymphatic abnormalities in pre-Fontan patients, rather than in patients after Tetralogy of Fallot repair.

Conclusion

In this current study, 3 out of 9 repaired tetralogy of Fallot patients exhibited type 3 abnormal lymphatic vessels in the supraclavicular region and mediastinum. Furthermore, among these three patients, two displayed abnormal tortuosity of the thoracic duct, despite the absence of any clinical signs of lymphatic disease. The significance of these anomalies remains uncertain currently. Further research is needed to determine whether these lymphatic alterations in this patient cohort are a result of congenital malformations, haemodynamic shifts, or prenatal and early-life saturation levels.

Supplementary material

The supplementary material for this article can be found at https://doi.org/10.1017/S1047951124025435.

Acknowledgements

The authors would like to express their gratitude to the radiographers who conducted the lymphatic magnetic resonance scans at the Department of Diagnostic Radiology, Rigshospitalet. They are also thankful for the assistance provided by the nurses (Maria Simmelkjær and Natasja Kramer) in booking the rooms for the near-infrared fluorescence imaging at the Department of Pediatric Surgery, Rigshospitalet.

Financial support

This project was supported by a grant from the Novo Nordic Foundation (NNF17OC0029854).

Competing interests

None.

Ethical standards

The study received approval from the Ethical Committee of the Capital Region of Denmark (H-19042934) and was conducted in compliance with the Helsinki Declaration. Both parents provided written informed consent before their involvement in the study. Furthermore, the study was registered with the Danish Data Protection Agency and conducted by the General Data Protection Regulation to ensure the protection of personal data and privacy.

References

Mavroudis, CD, Mavroudis, CD, Jacobs, JP et al. Procedure-Based Complications to Guide Informed Consent: Analysis of Society of Thoracic Surgeons-Congenital Heart Surgery Database. Ann Thorac Surg 2014; 97: 18381851. DOI: 10.1016/j.athoracsur.2013.12.037.CrossRefGoogle ScholarPubMed
Mouws, EMJP, De Groot, NMS, Van De Woestijne, PC et al. Tetralogy of Fallot in the current era. Semin Thorac Cardiovasc Surg 2019; 31: 496504. DOI: 10.1053/j.semtcvs.2018.10.015.CrossRefGoogle ScholarPubMed
Vaynblat, M, Chiavarelli, M, Anderson, JE, Rao, S, Nudel, DB, Cunningham, JN. Pleural drainage after repair of Tetralogy of Fallot. J Card Surg 1997; 12: 7176. DOI: 10.1111/J.1540-8191.1997.TB00097.X.CrossRefGoogle ScholarPubMed
Doerr, CH, Allen, MS, Nichols, FC, Ryu, JH. Etiology of chylothorax in 203 patients. Mayo Clin Proc 2005; 80: 867870. DOI: 10.4065/80.7.867.CrossRefGoogle ScholarPubMed
Biondi, JW, Schulman, DS, Wiedemann, HP, Matthay, RA. Mechanical heart-lung interaction in the adult respiratory distress syndrome. Clin Chest Med 1990; 11: 691714. DOI: 10.1016/s0272-5231(21)00763-2.CrossRefGoogle ScholarPubMed
Talwar, S, Agarwala, S, Mittal, CM, Choudhary, SK, Airan, B. Pleural effusions in children undergoing cardiac surgery. Ann Pediatr Cardiol 2010; 3: 5864. DOI: 10.4103/0974-2069.64368.CrossRefGoogle ScholarPubMed
Egbe, AC, Connolly, HM, Miranda, WR, Scott, CG, Borlaug, BA. Prognostic implications of inferior vena cava haemodynamics in ambulatory patients with Tetralogy of Fallot. ESC Hear Fail 2020; 7: 25892596. DOI: 10.1002/ehf2.CrossRefGoogle ScholarPubMed
Brace, RA, Valenzuela, GJ. Effects of outflow pressure and vascular volume loading on thoracic duct lymph flow in adult sheep. Am J Physiol - Regul Integr Comp Physiol 1990; 258: 27–21. DOI: 10.1152/ajpregu.1990.258.1.r240.CrossRefGoogle ScholarPubMed
Bailliard, F, Anderson, RH. Tetralogy of Fallot. Orphanet J Rare Dis 2009; 4: 2. DOI: 10.1186/1750-1172-4-2.CrossRefGoogle ScholarPubMed
Sun, L, van Amerom, JFP, Marini, D et al. MRI characterization of hemodynamic patterns of human fetuses with cyanotic congenital heart disease. Ultrasound Obstet Gynecol 2021; 58: 824836. DOI: 10.1002/uog.23707.CrossRefGoogle ScholarPubMed
Wise-Faberowski, L, Asija, R, McElhinney, DB. Tetralogy of Fallot: Everything you wanted to know but were afraid to ask. Pediatr Anesth 2019; 29: 475482. DOI: 10.1111/PAN.13569.CrossRefGoogle ScholarPubMed
Egbe, AC, Bonnichsen, C, Reddy, YNV, Anderson, V, Borlaug, JH, BA. Pathophysiologic and Prognostic Implications of Right Atrial Hypertension in Adults With Tetralogy of Fallot. J Am Heart Assoc 2019; 8: e014148. DOI: 10.1161/JAHA.119.CrossRefGoogle ScholarPubMed
Biko, DM, DeWitt, AG, Pinto, EM et al. MRI evaluation of lymphatic abnormalities in the neck and thorax after Fontan surgery: Relationship with outcome. Radiol 2019; 291: 774780. DOI: 10.1148/radiol 2019.CrossRefGoogle ScholarPubMed
Castellanos, DA, Ahmad, S, St. Clair, N et al. Magnetic resonance three-dimensional steady-state free precession imaging of the thoracic duct in patients with Fontan circulation and its relationship to outcomes. J Cardiovasc Magn Reson 2023; 25: 28. DOI: 10.1186/S12968-023-00937-W.CrossRefGoogle ScholarPubMed
Holm-Weber, T, Kristensen, RE, Mohanakumar, S, Hjortdal, VE. Gravity and lymphodynamics. Physiol Rep 2022; 10: e15289. DOI: 10.14814/PHY2.15289.CrossRefGoogle ScholarPubMed
Mohanakumar, S, Telinius, N, Kelly, B et al. Morphology and Function of the Lymphatic Vasculature in Patients with a Fontan Circulation. Circ Cardiovasc Imaging 2019; 12: e008074. DOI: 10.1161/CIRCIMAGING.118.008074.CrossRefGoogle ScholarPubMed
Kelly, B, Mohanakumar, S, Telinius, N, Alstrup, M, Alstrup, M, Hjortdal, V. Function of Upper Extremity Human Lymphatics Assessed by near-Infrared Fluorescence Imaging. Lymphat Res Biol 2020; 18: 226231. DOI: 10.1089/lrb.2019.0041.CrossRefGoogle ScholarPubMed
Mathematics A. ImageJ. 2016:1-23. https://imagej.nih.gov/ij/.CrossRefGoogle Scholar
Mohanakumar, S, Kelly, B, Turquetto, ALR et al. Functional lymphatic reserve capacity is depressed in patients with a Fontan circulation. Physiol Rep 2021; 9: e14862. DOI: 10.14814/PHY2.14862.CrossRefGoogle ScholarPubMed
Witte, MH, Dumont, AE, Clauss, RH, Rader, B, Levine, N, Breed, ES. Lymph circulation in congestive heart failure: effect of external thoracic duct drainage. Circulation 1969; 39: 723733. DOI: 10.1161/01.CIR.39.6.723.CrossRefGoogle ScholarPubMed
Cullen, S, Shore, D, Redington, A. Characterization of right ventricular diastolic performance after complete repair of Tetralogy of Fallot: Restrictive physiology predicts slow postoperative recovery. Circulation 1995; 91: 17821789. DOI: 10.1161/01.CIR.91.6.1782/FORMAT/EPUB.CrossRefGoogle Scholar
Rychik, J, Atz, AM, Celermajer, DS et al. Evaluation and Management of the Child and Adult With Fontan Circulation: A Scientific Statement from the American Heart Association. Circulation 2019; 140: E234E284. DOI: 10.1161/CIR.0000000000000696.CrossRefGoogle ScholarPubMed
Brogan, TV, Finn, LS, Pyskaty, DJ et al. Plastic bronchitis in children: a case series and review of the medical literature. Pediatr Pulmonol 2002; 34: 482487. DOI: 10.1002/PPUL.10179.CrossRefGoogle ScholarPubMed
Mallula, KK, Kenny, D, Hijazi, ZM. Transjugular melody valve placement in a small child with protein losing enteropathy. Catheter Cardiovasc Interv 2015; 85: 267270. DOI: 10.1002/CCD.25487.CrossRefGoogle Scholar
Datar, SA, Johnson, EG, Oishi, PE et al. Altered lymphatics in an ovine model of congenital heart disease with increased pulmonary blood flow. Am J Physiol Lung Cell Mol Physiol 2011; 302: 530540. DOI: 10.1152/AJPLUNG.00324.2011.CrossRefGoogle Scholar
Feltes TF, Hansen TN, Timothy Feltes CF, Professor of Pediatrics and A, of Pediatrics P, Assistant. Effects of an Aorticopulmonary Shunt on Lung Fluid Balance in the Young Lamb. Int Pediatr Res Found Inc 1989; 26: 94–97. DOI: 10.1203/00006450-198908000-00004.Google Scholar
Raj, JU, Hazinski, TA, Bland, RD. Effect of hypoxia on lung lymph flow in newborn lambs with left atrial hypertension. Am J Physiol - Hear Circ Physiol 1988; 254: H487H493. DOI: 10.1152/AJPHEART.1988.254.3.H487.CrossRefGoogle ScholarPubMed
Hansen, TN, Haberkern, CM, Hazinski, TA, Bland, RD. Lung fluid balance in hypoxic lambs. Pediatr Res 1984; 18: 434440. DOI: 10.1203/00006450-198405000-00009.CrossRefGoogle ScholarPubMed
Boehme, JT, Morris, CJ, Chiacchia, SR et al. HIF-1α promotes cellular growth in lymphatic endothelial cells exposed to chronically elevated pulmonary lymph flow. Sci Rep 2021; 11: 114. DOI: 10.1038/s41598-020-80882-1.CrossRefGoogle ScholarPubMed
Morfoisse, F, Renaud, E, Hantelys, F, Prats, AC, Garmy-Susini, B. Role of hypoxia and vascular endothelial growth factors in lymphangiogenesis. Mol Cell Oncol 2015; 2: 24821. DOI: 10.1080/23723556.2015.Google ScholarPubMed
Kristensen, R, Kelly, B, Kim, E, Dori, Y, Hjortdal, VE. Lymphatic Abnormalities on Magnetic Resonance Imaging in Single-Ventricle Congenital Heart Defects Before Glenn Operation. J Am Hear Assoc Cardiovasc Cerebrovasc Dis 2023; 12: 2937629376. DOI: 10.1161/JAHA.123.Google ScholarPubMed
Figure 0

Figure 1. Tetralogy of Fallot.

Figure 1

Figure 2. Tetralogy of Fallot.

Figure 2

Table 1. Surgical history and MRI findings of the tetralogy of Fallot patients

Figure 3

Table 2. Characteristics of the three tetralogy of Fallot patients exhibiting lymphatic MRI type 3 abnormal lymphatics concerning pre-repair, repair, and post-repair periods

Supplementary material: File

Holm-Weber et al. supplementary material

Holm-Weber et al. supplementary material
Download Holm-Weber et al. supplementary material(File)
File 1.7 MB