Hostname: page-component-586b7cd67f-r5fsc Total loading time: 0 Render date: 2024-11-24T17:39:47.981Z Has data issue: false hasContentIssue false

Catheter closure of a residual aortopulmonary window after corrective surgery

Published online by Cambridge University Press:  19 August 2008

H. P. Gildein*
Affiliation:
From the Department of Pediatric Cardiology, University of Freiburg, Freiburg
R. Mocellin
Affiliation:
From the Department of Pediatric Cardiology, University of Freiburg, Freiburg
*
Dr. H. P. Gildein, Abteilung Pädiatrische Kardiologie, Universitäts-Kinderklinik, Mathildenstraße 1, 79106 Freiburg, Germany. Tel. 49-761-270 4317; Fax. 49-761-270 4481.

Summary

Apart from its original use for closing an open duct, the Rashkind ductal occluder has been used to close a variety of other defects. We report successful use of this device to close a residual aortopulmonary window persisting after corrective surgery had been carried out at the age of six months.

Type
Brief Reports
Copyright
Copyright © Cambridge University Press 1995

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Rashkind, WJ, Cuaso, CC.Transcatheter closure of patent ductus arteriosus Successful use in a 3.5-kilogram infant. Pediatr Cardiol 1979; 1: 37.CrossRefGoogle Scholar
Rashkind, WJ, Mullins, CE, Hellenbrand, WE, Tait, MA.Nonsurgical closure of patent ductus arteriosus: clinical application of the Rashkind PDA Occluder System. Circulation 1987; 75: 583592.CrossRefGoogle ScholarPubMed
Ali Khan, MA, Al Yousef, S, Mullins, CE, Sawyer, W.Experience with 205 procedures of transcatheter closure ofductus arteriosus in 182 patients, with special reference to residual shunts and long-term follow-up. J Thorac Cardiovasc Surg 1992; 104: 17211727.Google Scholar
Redington, AN, Rigby, ML.Novel uses of the Rashkind ductal umbrella in adults and children with congenital heart disease. Br Heart J 1993; 69: 4751.CrossRefGoogle ScholarPubMed
Houde, C, Zahn, EM, Benson, LN.Transcatheter closure of Blalock-Taussig shunts with a modified Rashkind umbrella delivery system. Br HeartJ 1993; 69: 5658.CrossRefGoogle ScholarPubMed
Perry, SB, Rome, J, Keane, JF, Baim, DS, Lock, JE.Transcatheter closure ofcoronary artery fistulas. J Am Coll Cardiol 1992; 20:205209.CrossRefGoogle Scholar
Lock, JE, Cockerham, JT, Keane, JF, Finley, JP, Wakely, PE, Fellows, KE.Transcatheter umbrella closure of congenital heart defects. Circulation 1987; 75: 593599.CrossRefGoogle ScholarPubMed