Validity of resting energy expenditure estimated by an activity monitor compared to indirect calorimetry

Published online by Cambridge University Press:  13 January 2009

Jocilyn E. Dellava
Affiliation:
Department of Nutritional Sciences, Rutgers, The State University of New Jersey, 26 Nichol Avenue, Room 288-B, New Brunswick, NJ08901, USA
Daniel J. Hoffman*
Affiliation:
Department of Nutritional Sciences, Rutgers, The State University of New Jersey, 26 Nichol Avenue, Room 288-B, New Brunswick, NJ08901, USA
*
*Corresponding author: Daniel J. Hoffman, fax +1 732 932 6522, email [email protected]
Rights & Permissions [Opens in a new window]

Abstract

The use of activity monitors (triaxial accelerometers) to estimate total energy expenditure in kilocalories is dependent on the estimation of resting energy expenditure (REE). However, the REE estimated by activity monitors has not been validated against more precise techniques, such as indirect calorimetry (IC). Therefore, the objective of the present study was to compare REE estimated by the Actical activity monitor (ActMon) to that measured by IC and standard prediction equations of REE. Fifty healthy adults between 18 and 43 years of age were measured for weight and percentage of body fat using a digital scale and bioelectrical impedance. The REE estimated by the ActMon was only 129 kJ/d higher, but not statistically different (P>0·05), than the REE measured with IC. Using multiple linear regression, there was a positive relationship for men, but not for women, between fat mass (kg) and percentage of body fat and the difference in REE estimated by the ActMon compared to IC (P < 0·001). Therefore, in the cohort studied, the use of an activity monitor to estimate REE is valid when compared to IC, but not to a standard prediction equation of REE.

Type
Full Papers
Copyright
Copyright © The Authors 2009

Activity monitors (i.e. triaxial accelerometer) provide objective estimates of energy expenditure for physical activity (EEPA) by tracking movements in one-, two- or three-axes to estimate EEPA(Reference Bouten, Koekkoek and Verduin1, Reference Westerterp2). Given that the prevalence of obesity continues to increase worldwide(Reference Ogden, Carroll and Curtin3, Reference James, Rigby and Leach4), studying modifiable aspects of energy balance, such as EEPA, has become a priority. Thus, the use of activity monitors has increased greatly as many investigators conduct studies on the aetiology or prevention of obesity(Reference LaPorte, Kuller and Kupfer5Reference Jago, Baranowski and Yoo7). Recently, some activity monitors have introduced estimates of total energy expenditure (TEE) by coupling estimates of EEPA and resting energy expenditure (REE). However, there is a serious lack of data on the validity of activity monitors to estimate REE, a key and significant component of TEE.

Currently, techniques used to measure TEE or EEPA are either accurate, costly and labour intensive (e.g. doubly labelled water for TEE) or inaccurate, simple and inexpensive (e.g. prediction equations or questionnaires). Doubly labelled water is reported to be as precise as direct calorimetry ( ± 3–7 %), but can be technically and fiscally prohibitive, especially for investigators in less developed countries(Reference Roberts8). On the other hand, prediction equations or questionnaires are relatively inexpensive, but are generally inaccurate in terms of quantifying TEE or EEPA(Reference Blaak, Westerterp and Bar-Or9Reference Seale, VanZant and Conway11). Thus, the use of activity monitors to provide an unbiased, objective estimate of EEPA and/or TEE has proven useful for investigators without the financial or technical ability to employ more precise techniques.

Some manufacturers of activity monitors have added a feature that estimates REE, using age, sex, height and weight, and provide a reasonable estimate of TEE by adding the estimated REE to the estimated EEPA(Reference Puyau, Adolph and Vohra12Reference Lopez-Alarcon, Merrifield and Fields15). However, not all of these models have been validated for estimates of TEE, nor have they been shown to produce a reliable estimate of REE. More importantly, it has not been reported whether or not the estimates of REE used by activity monitors are valid for persons of low or high percentage of body fat (BF), results that could over- or underestimate the TEE of thin or obese individuals. In fact, a recent study reported that, while the activity monitor used was valid for TEE, great attention needs to be provided to the estimation of REE(Reference Hustvedt, Svendsen and Lovo16). Thus, the objective of the present study was to compare the REE estimated by an activity monitor to that measured with indirect calorimetry (IC) and standard prediction equations of REE, in a group of adult men and women to determine the differences in the estimates by either sex or body composition.

Experimental methods

Subjects

We studied fifty healthy men and women who were recruited from the general population of faculty, staff and students at Rutgers University via flyers and announcements. Subjects who had a chronic disease (e.g. cancer, type 2 diabetes, etc.), were pregnant, had a history of thyroid disease or were currently taking medication known to influence metabolism (e.g. insulin, over-the-counter diet pills) were excluded from the study. The protocol used in the present study was approved by the Rutgers University Institutional Review Board for the Protection of Human Subjects and informed written consent was obtained from all volunteers.

Anthropometrics

Height was measured to the nearest 0·1 cm using a stadiometer, body weight was measured to the nearest 0·1 kg and percentage of BF was measured to the nearest 0·1 % using a leg-to-leg bioelectrical impedance analysis (BIA) scale (Tanita BF-578, Tanita Corp, Tokyo, Japan).

Indirect calorimetry

REE was measured using IC while the subject was resting, but not sleeping (VMax Spectra 29N, Sensormedics, Inc., Yorba Linda, CA, USA). As we were measuring REE and not basal metabolism, the subjects were allowed to drive to the metabolic unit where they were asked to rest for 30 min before beginning the measurement. All subjects were asked to fast for 12 h and refrain from exercise 16 h before the measurement. No records of dietary intake were kept and the food quotient of the antecedent day was not estimated, as this has been found to influence substrate oxidation, but not REE. While the phase of the menstrual cycle does not have an effect on substrate oxidation(17), there is no real consensus on the influence of the menstrual cycle on REE(Reference Melanson, Saltzman and Russell17Reference Horton, Miller and Glueck19), and female participants were measured in any phase of their menstrual cycle. Also, daily exercise can increase REE for up to 24 h(Reference Jamurtas, Koutedakis and Paschalis20, Reference Hunter, Byrne and Gower21), but we did not ask the subjects to alter their normal exercise routines since we were assessing REE within the subjects under normal living conditions. The REE was measured at 20 s intervals for 30 min and the first 10 min of data were not used in the calculation of REE. Movement during the measurement was minimised by having a staff member remain in the metabolic unit to either wake the subjects who appeared to be sleeping or remind the subjects to remain still. The IC was calibrated before each measurement using a standard gas containing carbon dioxide (4 %) and oxygen (16 %).

Activity monitor

The activity monitor (Actical® physical activity monitor, Mini Mitter, Bend, OR, USA) was programmed according to the manufacturer's instruction by entering the height, weight, age and sex of each subject. The subjects were instructed to place the Actical activity monitor (ActMon) on his or her waist and wear it for the entire time during which baseline readings were measured. The data from the activity monitor were downloaded using the manufacturer's software and then entered into SPSS (SPSS Inc., Chicago, IL, USA).

Prediction equations for estimating REE. Since it is assumed that the proprietary algorithm used is most likely based on a prediction equation to estimate REE, it was of interest to compare the REE estimated by the ActMon with standard equations. The Harris–Benedict and Mifflin equations are two such prediction equations that have been shown to be valid in both normal-weight and obese populations and are often used in research and clinical practices to predict REE(Reference Mifflin, St Jeor and Hill22, Reference De Lorenzo, Tagliabue and Andreoli23). We used each equation to estimate REE and performed paired t tests to compare the value predicted by each equation to that of the ActMon.

Statistical analysis

The subjects were analysed as a group and by sex. The data were normally distributed and differences between the two methods studied were analysed using paired-sample Student's t test. Pearson's correlations were calculated to determine the relationship between the REE estimated from the ActMon and that from the IC. The Bland–Altman plots(Reference Bland and Altman24, Reference Bland and Altman25) of the differences between REE estimated by the ActMon and REE measured using IC v. the average of the two methods were used to show the reliability of the REE predicted by the activity monitor. Multiple linear regression analyses were conducted, in which we used the difference in REE between the two methods (REE estimated by the ActMon − REE measured by IC) as the dependent variable and fat mass (FM) and fat-free mass as the independent variables: model 1, FM, fat-free mass, height, sex and age; model 2, percentage of BF, height, sex and age. Only significant predictors of the difference in REE between the two methods were allowed to remain in the analyses. For model 1, while fat-free mass was not a significant predictor, it is a large component of body weight, a key variable used in prediction equations, and was allowed to remain in the analyses. There was significant collinearity between percentage of BF and FM with sex, so the data were split by sex. Also, one male subject was found to be a statistical outlier for FM as determined by a stem-and-leaf plot and test for outliers, but he was left in the dataset as there was no change in the statistical significance of the models when he was excluded from the analyses, and there was no technical or biological reason to believe that his values were spurious. All analyses were conducted using SPSS 13.0 for Windows (SPSS Inc.) and statistical significance was set at P < 0·05.

Results

The group studied consisted of nineteen men and thirty-one women with a mean BMI (kg/m2) of 24·1 and 22·6, respectively, and percentage of BF of 15·8 and 25·4, respectively (Table 1).

Table 1 Physical characteristics of the study participants

(Mean values and standard deviations)

The REE predicted by the ActMon was not significantly different from that measured by IC when analysed combined or by sex (Table 2). The Bland–Altman plots of the differences in these values are shown in Fig. 1. When compared to standard prediction equations (Table 2), the ActMon estimated an REE that was not significantly different from the Mifflin equation, combined or by sex, but it did estimate an REE that was significantly lower than the Harris–Benedict equation for the group and each sex (P < 0·001). Estimated and measured REE were significantly correlated (Table 3), even when split by sex.

Table 2 Resting energy expenditure estimated by the Actical activity monitor (ActMon) and standard prediction equations or measured by indirect calorimetry (IC), and the differences between the ActMon estimate and each method

(Mean values and standard deviations)

*P < 0·001.

Fig. 1 Bland–Altman plots of the differences in resting energy expenditure (REE, kJ/d) measured by indirect calorimetry (IC) and REE estimated by the Actical activity monitor (ActMon).

Table 3 Correlation between resting energy expenditure estimated by the Actical activity monitor and measured by indirect calorimetry for the total sample as well as for men and women

The relationship between the differences in estimated and measured REE and body composition was analysed by sex, as stated previously, and is summarised in Tables 4 and 5. For men, FM (model 1) and percentage of BF (model 2) each had a significant positive relationship with the difference in REE estimated by the ActMon compared to that measured by IC (P < 0·001), such that for those with a low FM or percentage of BF, the ActMon underestimated REE, while for those with a high FM or percentage of BF, REE was overestimated. Similar results were not found for women.

Table 4 Multiple linear regression analyses of the relationship between body composition (fat mass and fat-free mass) in men (model 1a) and women (model 1b) and the difference in resting energy expenditure estimated by the Actical activity monitor and indirect calorimetry

Table 5 Multiple linear regression analyses of the relationship between body composition (percentage of body fat (%BF), height, sex and age) in men (model 2a) and women (model 2b) and the difference in resting energy expenditure estimated by the Actical activity monitor and indirect calorimetry

%FM, percentage of fat mass.

Discussion

The worldwide need to better understand the aspects of daily energy expenditure, such as EEPA, becomes more important as the prevalence of obesity continues to increase worldwide(Reference Arroyo, Loria and Fernandez26Reference James29). Methods to measure TEE and EEPA are needed for large studies of free-living adults, but most accurate methods are technically difficult and prohibitively expensive. Activity monitors are relatively easy to use, accurate and cost-effective tools, which can estimate TEE and EEPA. However, activity monitors that use algorithms to estimate REE, a key component in calculating TEE, have not been evaluated for their reliability. More importantly, the influence of body composition on REE estimated by activity monitors has not been reported. Briefly, we found that the REE estimated by the ActMon was similar to that measured by IC. However, the REE for men was overestimated by the activity monitor as FM or percentage of BF increased. Thus, the use of an activity monitor for estimating TEE may be limited when used in persons with FM or percentage of BF at the extremes, similar to what is expected from traditional prediction equations.

The major implication of the present results is that, while the mean estimate from the ActMon differed from IC by only 129 kJ/d (6 kJ/d for men and 211 kJ/d for women), the absolute value of the differences indicated that the ActMon overestimated the REE by 566 kJ/d (636 kJ/d for men and 524 kJ/d for women). For individuals, the difference in estimated v. measured REE was as high as 1100 kJ/d. Thus, the use of activity monitors for individual measurements should be conservative since there is a chance of real under- or overestimation of energy requirements. These issues may be relevant when one considers that activity monitors may be used for studies or programmes involving persons who are overweight or obese. It would thus seem prudent for investigators to balance the benefits of a quantitative measure of EEPA, such as using an activity monitor, with the potentially biased estimate of REE due to differences in body compositions; similar issues that already exist with existing prediction equations.

Prediction equations to estimate REE or TEE are reported to be acceptable for large population studies given their ease of use and general reliability(Reference Dobratz, Sibley and Beckman30Reference Vander Weg, Watson and Klesges32). A limitation of prediction equations is that the differences in body composition can bias estimates, a bias that will carry forward when used to predict TEE. Activity monitors, similar to prediction equations, do not accommodate differences in body composition and the predicted REE may be biased for persons with low or high percentage of BF. As we report, the REE estimated by the activity monitor was similar to one (Mifflin), but significantly different from the other (Harris–Benedict) prediction equation. Hustvedt et al. (Reference Hustvedt, Svendsen and Lovo16) reported that the use of IC coupled with activity monitors can eliminate some bias introduced by prediction equations. Yet, the REE estimated by the ActMon was in close agreement with the Mifflin equation, but not with the Harris–Benedict equation. Nonetheless, the real advantage of using activity monitors is that estimates of EEPA can be coupled with REE to estimate TEE. Also, activity monitors can provide unbiased and quantitative, minute-by-minute or hourly estimates of EEPA to quantify activity patterns, a feature that cannot be met by either prediction equations or doubly labelled water. However, it may be best to promote the use of activity monitors for large groups of normal-weight individuals to minimise the bias introduced by a large FM.

It is important to discuss limitations of the present study. First, each subject was only measured once, thereby not allowing us to estimate the intra-individual variation in REE. Yet, it is unlikely that this factor alone would result in a systematic bias of the differences in REE estimated by the ActMon and IC as there is no reason that all subjects studied would have a higher or lower REE than usual on the day of the study. Second, it would be helpful to conduct additional measurements in which we recruited more men with high body FM as we had only two men with percentage of BF greater than 25, but these results did not influence the fact that REE estimated by the ActMon was close to that measured by IC, the main objective of the present study. Third, to facilitate recruitment and data collection on a relatively large clinical sample, we did not control for all factors that could influence REE, such as daily exercise or menstrual phase, but these factors are not likely to produce a systematic bias of the results. Fourth, there were three pairs of twins who participated in the study, but the relatedness of these twins was not controlled for in our analyses. Finally, BIA, our measure of body composition, is not without criticism. For example, there was no way to ensure that all of the subjects in the present study had the same level of hydration, a factor that is known, during either dehydration or overhydration, to influence body-composition estimates by BIA(Reference Thompson, Thompson and Prestridge33Reference Bray, DeLany and Harsha35). The BIA equipment we used only estimated leg-to-leg body composition and not total body composition, but several studies have reported that leg-to-leg BIA is comparable to total body BIA(Reference de Fijter, de Fijter and Oe34, Reference Nunez, Gallagher and Visser36).

In conclusion, based on the results of the present study, we found that the ActMon provides a reliable estimate of REE compared to IC, but there may be a potential for the overestimation of both REE and TEE when used on men who have a high FM or percentage of BF, a factor that warrants additional research on more overweight men. Yet, activity monitors can be useful by providing information on EEPA without subject bias. In conclusion, activity monitors are valuable tools, but limitations may exist if used in a cohort with a high proportion of overweight or obese adults and may be inappropriate for individual assessment of energy requirements.

Acknowledgements

We would like to extend our gratitude to the volunteers who gave up their mornings to participate in the present study. The authors state that there are no conflicts of interest related to the present research. J. E. D. contributed to the design, subject recruitment, data collection and analyses, and drafting of the manuscript. D. J. H. contributed to the design, data analyses, drafting of the manuscript and funding of the study.

References

1Bouten, CV, Koekkoek, KT, Verduin, M, et al. (1997) A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity. IEEE Trans Biomed Eng 44, 136147.Google Scholar
2Westerterp, KR (1999) Physical activity assessment with accelerometers. Int J Obes Relat Metab Disord 23, Suppl. 3, S45S49.Google Scholar
3Ogden, CL, Carroll, MD, Curtin, LR, et al. (2006) Prevalence of overweight and obesity in the United States, 1999–2004. J Am Med Assoc 295, 15491555.Google Scholar
4James, PT, Rigby, N & Leach, R (2004) The obesity epidemic, metabolic syndrome and future prevention strategies. Eur J Cardiovasc Prev Rehabil 11, 38.CrossRefGoogle ScholarPubMed
5LaPorte, RE, Kuller, LH, Kupfer, DJ, et al. (1979) An objective measure of physical activity for epidemiologic research. Am J Epidemiol 109, 158168.CrossRefGoogle ScholarPubMed
6Johannsen, DL, Welk, GJ, Sharp, RL, et al. (2008) Differences in daily energy expenditure in lean and obese women: the role of posture allocation. Obesity (Silver Spring) 16, 3439.CrossRefGoogle ScholarPubMed
7Jago, R, Baranowski, T, Yoo, S, et al. (2004) Relationship between physical activity and diet among African–American girls. Obes Res 12, Suppl. 55S63S.CrossRefGoogle ScholarPubMed
8Roberts, SB (1989) Use of the doubly labeled water method for measurement of energy expenditure, total body water, water intake, and metabolizable energy intake in humans and small animals. Can J Physiol Pharmacol 67, 11901198.CrossRefGoogle ScholarPubMed
9Blaak, EE, Westerterp, KR, Bar-Or, O, et al. (1992) Total energy expenditure and spontaneous activity in relation to training in obese boys. Am J Clin Nutr 55, 777782.Google Scholar
10Kriska, A (2000) Ethnic and cultural issues in assessing physical activity. Res Q Exerc Sport 71, Suppl. 2, S47S53.Google Scholar
11Seale, JL, VanZant, RS & Conway, JM (1996) Free-living, 24-hour, and sleeping energy expenditure in sedentary, strength-trained, and endurance-trained men. Int J Sport Nutr 6, 370381.CrossRefGoogle ScholarPubMed
12Puyau, MR, Adolph, AL, Vohra, FA, et al. (2002) Validation and calibration of physical activity monitors in children. Obes Res 10, 150157.CrossRefGoogle ScholarPubMed
13Rodriguez, DA, Brown, AL & Troped, PJ (2005) Portable global positioning units to complement accelerometry-based physical activity monitors. Med Sci Sports Exerc 37, Suppl. 11, S572S581.CrossRefGoogle ScholarPubMed
14Chen, KY & Bassett, DR Jr (2005) The technology of accelerometry-based activity monitors: current and future. Med Sci Sports Exerc 37, Suppl. 11, S490S500.Google Scholar
15Lopez-Alarcon, M, Merrifield, J, Fields, DA, et al. (2004) Ability of the actiwatch accelerometer to predict free-living energy expenditure in young children. Obes Res 12, 18591865.Google Scholar
16Hustvedt, BE, Svendsen, M, Lovo, A, et al. (2008) Validation of ActiReg to measure physical activity and energy expenditure against doubly labelled water in obese persons. Br J Nutr 100, 219226.Google Scholar
17Melanson, KJ, Saltzman, E, Russell, R, et al. (1996) Postabsorptive and postprandial energy expenditure and substrate oxidation do not change during the menstrual cycle in young women. J Nutr 126, 25312538.CrossRefGoogle Scholar
18Solomon, SJ, Kurzer, MS & Calloway, DH (1982) Menstrual cycle and basal metabolic rate in women. Am J Clin Nutr 36, 611616.CrossRefGoogle ScholarPubMed
19Horton, TJ, Miller, EK, Glueck, D, et al. (2002) No effect of menstrual cycle phase on glucose kinetics and fuel oxidation during moderate-intensity exercise. Am J Physiol Endocrinol Metab 282, E752E762.Google Scholar
20Jamurtas, AZ, Koutedakis, Y, Paschalis, V, et al. (2004) The effects of a single bout of exercise on resting energy expenditure and respiratory exchange ratio. Eur J Appl Physiol 92, 393398.Google Scholar
21Hunter, GR, Byrne, NM, Gower, BA, et al. (2006) Increased resting energy expenditure after 40 minutes of aerobic but not resistance exercise. Obesity (Silver Spring) 14, 20182025.CrossRefGoogle Scholar
22Mifflin, MD, St Jeor, ST, Hill, LA, et al. (1990) A new predictive equation for resting energy expenditure in healthy individuals. Am J Clin Nutr 51, 241247.CrossRefGoogle ScholarPubMed
23De Lorenzo, A, Tagliabue, A, Andreoli, A, et al. (2001) Measured and predicted resting metabolic rate in Italian males and females, aged 18–59 y. Eur J Clin Nutr 55, 208214.CrossRefGoogle ScholarPubMed
24Bland, JM & Altman, DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8, 135160.CrossRefGoogle ScholarPubMed
25Bland, JM & Altman, DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet i, 307310.Google Scholar
26Arroyo, P, Loria, A, Fernandez, V, et al. (2000) Prevalence of pre-obesity and obesity in urban adult Mexicans in comparison with other large surveys. Obes Res 8, 179185.CrossRefGoogle ScholarPubMed
27de Onis, M & Blossner, M (2000) Prevalence and trends of overweight among preschool children in developing countries. Am J Clin Nutr 72, 10321039.Google Scholar
28Ginter, E & Simko, V (2008) Adult obesity at the beginning of the 21st century: epidemiology, pathophysiology and health risk. Bratisl Lek Listy 109, 224230.Google ScholarPubMed
29James, WP (2008) The epidemiology of obesity: the size of the problem. J Intern Med 263, 336352.Google Scholar
30Dobratz, JR, Sibley, SD, Beckman, TR, et al. (2007) Predicting energy expenditure in extremely obese women. JPEN J Parenter Enteral Nutr 31, 217227.Google Scholar
31de Luis, DA, Aller, R, Izaola, O, et al. (2006) Prediction equation of resting energy expenditure in an adult Spanish population of obese adult population. Ann Nutr Metab 50, 193196.Google Scholar
32Vander Weg, MW, Watson, JM, Klesges, RC, et al. (2004) Development and cross-validation of a prediction equation for estimating resting energy expenditure in healthy African–American and European–American women. Eur J Clin Nutr 58, 474480.Google Scholar
33Thompson, DL, Thompson, WR, Prestridge, TJ, et al. (1991) Effects of hydration and dehydration on body composition analysis: a comparative study of bioelectric impedance analysis and hydrodensitometry. J Sports Med Phys Fitness 31, 565570.Google ScholarPubMed
34de Fijter, CW, de Fijter, MM, Oe, LP, et al. (1993) The impact of hydration status on the assessment of lean body mass by body electrical impedance in dialysis patients. Adv Perit Dial 9, 101104.Google Scholar
35Bray, GA, DeLany, JP, Harsha, DW, et al. (2001) Evaluation of body fat in fatter and leaner 10-y-old African American and white children: the Baton Rouge Children's Study. Am J Clin Nutr 73, 687702.CrossRefGoogle ScholarPubMed
36Nunez, C, Gallagher, D & Visser, M (1997) Bioimpedance analysis: evaluation of leg-to-leg system based on pressure contact footpad electrodes. Med Sci Sports Exerc 29, 524531.Google Scholar
Figure 0

Table 1 Physical characteristics of the study participants(Mean values and standard deviations)

Figure 1

Table 2 Resting energy expenditure estimated by the Actical activity monitor (ActMon) and standard prediction equations or measured by indirect calorimetry (IC), and the differences between the ActMon estimate and each method(Mean values and standard deviations)

Figure 2

Fig. 1 Bland–Altman plots of the differences in resting energy expenditure (REE, kJ/d) measured by indirect calorimetry (IC) and REE estimated by the Actical activity monitor (ActMon).

Figure 3

Table 3 Correlation between resting energy expenditure estimated by the Actical activity monitor and measured by indirect calorimetry for the total sample as well as for men and women

Figure 4

Table 4 Multiple linear regression analyses of the relationship between body composition (fat mass and fat-free mass) in men (model 1a) and women (model 1b) and the difference in resting energy expenditure estimated by the Actical activity monitor and indirect calorimetry

Figure 5

Table 5 Multiple linear regression analyses of the relationship between body composition (percentage of body fat (%BF), height, sex and age) in men (model 2a) and women (model 2b) and the difference in resting energy expenditure estimated by the Actical activity monitor and indirect calorimetry