Hostname: page-component-cd9895bd7-lnqnp Total loading time: 0 Render date: 2024-12-19T00:28:09.656Z Has data issue: false hasContentIssue false

SG-APSIC1112: The quality enhancement in sterilization processes at Naresuan University Hospital

Published online by Cambridge University Press:  16 March 2023

Kanokporn Wilachai*
Affiliation:
Central Sterilizing Services Association, Naresuan University Hospital, Tha Pho, Phitsanulok, Thailand

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Background: Disinfection and sterilization of medical devices, instruments, and medical supplies are a crucial part of hospital infection control. The significant problems include insufficient cleaning, incorrect registration in the request form, no basic cleaning at the point of use (POS), and incorrect labelling. These problems were analyzed according using the fishbone diagram process. Objectives: We sought to decrease insufficient cleanliness of items after washing, to increase data accuracy in transferring contaminated devices from wards (from end users), to increase the rate of decontamination at the point of use, and to decrease incorrect labelling on instrument packaging. Method: The Community of Practice in Sterilization (CoP Sterile) team revised the disinfection and sterilization system of the Naresuan University Hospital Central Sterile Supply Department (CSSD) using root-cause analysis of subprocess problems and implementing prioritized solutions. A regular monthly meeting was set up to ensure active response, and closed monitoring was performed to ensure the implementation of the revised protocol according to the plan–do–study–act (PDSA) process. Results: From 2019 to 2021, the percentages of annual insufficient cleanliness of items after washing decreased from 4.8% to 3.6% to 3.1% each year. The percentages of incorrect request forms decreased from 14.59% to 2.91% to 1.84% during these same years. The percentages of decontamination ignorance at the point of use decreased from 3.13% to 0.12% to 0.03% from 2019 to 2021. The percentages of incorrect labelling were 0.013%, 0.008%, and 0.013% each year. Conclusions: The CoP Sterile team used quality improvement tools and regular monitoring to achieve reductions in insufficient cleanliness and incorrect request forms and to increase knowledge of decontamination procedures.

Type
Sterilization and Disinfection
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
© The Author(s), 2023. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America