Hostname: page-component-586b7cd67f-tf8b9 Total loading time: 0 Render date: 2024-12-03T19:26:54.290Z Has data issue: false hasContentIssue false

Hand hygiene behavior change: a review and pilot study of an automated hand hygiene reminder system implementation in a public hospital

Published online by Cambridge University Press:  10 July 2023

Arta Seferi
Affiliation:
Department of Nursing, New York City Health + Hospitals/South Brooklyn Health, Brooklyn, NY, USA
Kalliopi Parginos
Affiliation:
Department of Nursing, New York City Health + Hospitals/South Brooklyn Health, Brooklyn, NY, USA
Wiline Jean
Affiliation:
Department of Infection Prevention, New York City Health + Hospitals/South Brooklyn Health, Brooklyn, NY, USA HealthCare Transformation, Chicago, IL, USA
Christopher Calero
Affiliation:
Department of Infection Prevention, New York City Health + Hospitals/South Brooklyn Health, Brooklyn, NY, USA
Joshua Fogel
Affiliation:
Department of Obstetrics and Gynecology, New York City Health + Hospitals/South Brooklyn Health, Brooklyn, NY, USA Department of Business Management, Brooklyn College, Brooklyn, NY, USA
Shantel Modeste
Affiliation:
Department of Quality Management, New York City Health + Hospitals/South Brooklyn Health, Brooklyn, NY, USA
Beverley-Ann Scott
Affiliation:
Department of Quality Management, New York City Health + Hospitals/South Brooklyn Health, Brooklyn, NY, USA
Marjorie Daly-Walsh
Affiliation:
Department of Nursing, New York City Health + Hospitals/South Brooklyn Health, Brooklyn, NY, USA
Wilfredo Yap
Affiliation:
Department of Nursing, New York City Health + Hospitals/South Brooklyn Health, Brooklyn, NY, USA
Manjinder Kaur
Affiliation:
Department of Nursing, New York City Health + Hospitals/South Brooklyn Health, Brooklyn, NY, USA
Terence Brady
Affiliation:
Department of Medicine, New York City Health + Hospitals/South Brooklyn Health, Brooklyn, NY, USA Department of Medicine, St. George’s University School of Medicine, Grenada, West Indies
Theresa Madaline*
Affiliation:
Department of Medicine, New York City Health + Hospitals/South Brooklyn Health, Brooklyn, NY, USA Department of Medicine, St. George’s University School of Medicine, Grenada, West Indies Department of Medicine, Touro College of Osteopathic Medicine, New York, NY, USA Department of Medicine, New York Institute of Technology College of Osteopathic Medicine, New York, NY, USA
*
Corresponding author: Theresa Madaline; Email: [email protected]

Abstract

Objective:

To review and study implementation of an automated hand hygiene reminder system (AHHRS).

Design:

Prospective, nonrandomized, before-after quality improvement pilot study conducted over 6 months.

Setting:

Medical-surgical unit (MSU) and medical intensive care unit (MICU) at a public hospital in New York City.

Participants:

There were 2,642 healthcare worker observations in the direct observation (DO) period versus 265,505 in the AHHRS period, excluding AHHRS observations collected during the 1-month crossover period when simultaneous DO occurred.

Intervention:

We compared hand hygiene adherence (HHA) measured by DO prior to the pilot and after AHHRS implementation. We compared changes in HHA and potential cross-contamination events (CCEs) (room exit and subsequent entry without HHA) from baseline for each biweekly period during the pilot.

Results:

Engagement, education/training, data transparency, and optimization period resulted in successful implementation and adoption of the AHHRS. Observations were greater utilizing AHHRS than DO (265,505 vs 2,642, P < .01). Due to the expected Hawthorne effect, HHA was significantly less for AHHRS than DO in MSU (90.99% vs 97.21%, P < .01) and MICU (91.21% vs 98.65%, P < .01). HHA significantly improved from 86.47% to 89.68% in MSU (P < .001) and 85.93% to 91.24% in the MICU (P < .001) from the first biweekly period of AHHRS utilization to the last. CCE decreased from 73.42% to 65.11% in the MSU and significantly decreased from 81.22% to 53.19% in the MICU (P < .05).

Conclusions:

We describe how an AHHRS approach was successfully implemented at our facility. With ongoing feedback and system optimization, AHHRS improved HHA and reduced CCE over time.

Type
Review
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2023. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America

Introduction

The Centers for Disease Control and Prevention (CDC) estimates 1 in 31 hospitalized patients acquire a hospital-acquired infection (HAI) every year in the United States. Reference Magill, O’Leary and Janelle1 These preventable infections result in 99,000 deaths Reference Magill, Edwards and Bamberg2 and $30 billion spent yearly. Reference Scott3 Transmission of pathogens from the hands of healthcare workers (HCWs) to patients, and prevention of transmission through handwashing, was established in the 1800s by Ignaz Semmelweis. 4 Consistent performance of hand hygiene (HH) by HCWs remains a major barrier to reducing HAIs today. Reference Gould, Moralejo, Drey, Chudleigh and Taljaard5 HCWs can overlook this crucial patient safety measure due to high patient care demands, long hours, and structural barriers. Reference Pittet, Mourouga and Perneger6 A review reports that HH adherence (HHA) among HCWs is approximately 50%. Reference Kingston, O’Connell and Dunne7 Furthermore, HCWs are also at risk of self-contamination or infection. HH can prevent an exposure or infection in the clinical setting from gram-negative bacilli, methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococci (VRE), and C. difficile. Reference Sanderson and Weissler8Reference Sakamoto, Yamada, Suzuki, Sugiura and Tokuda13 HH can protect HCW from acquisition of influenza, respiratory syncytial virus (RSV), severe acute respiratory syndrome (SARS), and COVID-19 during patient care. Reference Tian, Lovrics and Vaisman14,Reference Hall and Douglas15

Hand hygiene measurement approaches

Direct observation (DO)

HH programs are a well-established infection prevention practice recommended by many organizations including the World Health Organization (WHO), the CDC, Infectious Diseases Society of America, and the American Hospital Association. 4,16Reference Ellingson, Haas and Aiello18 Direct observation (DO) of HH among HCWs is the gold standard for HH programs. This strategy has several advantages: (1) opportunity for real-time feedback and education, (2) observation of all five of WHO’s moments for HH (before patient contact, before aseptic task, after body fluid exposure risk, after patient contact, and after contact with patient surroundings), (3) evaluation of technique and product used, and (4) assess for appropriate use of gloves and other personal protective equipment. 4,16,Reference Ellingson, Haas and Aiello18Reference Pittet, Hugonnet and Harbarth21 However, DO for HH performance is limited by the Hawthorne effect, Reference Ellingson, Haas and Aiello18,Reference Hagel, Reischke and Kesselmeier22Reference Pan, Tien and Hung24 which is that the person under observation changes behavior due to presence of the observer. As HHA rates are higher when HCWs are aware they are being observed than when they are unaware, Reference Pan, Tien and Hung24 the practical utility of DO programs has limitations. Furthermore, DO is costly, labor-intensive, potentially subjective, and misses a significant number of opportunities, and the limited availability of observers can result in observations being performed disproportionately on certain days/times or locations. Reference Ellingson, Haas and Aiello18,Reference Haas and Larson19

Technology-assisted monitoring

Technology-assisted HHA monitoring strategies are used to overcome some barriers of DO, including reduction in the Hawthorne effect, decrease in the time of data collection, and increase in the opportunities captured. Reference Ellingson, Haas and Aiello18,Reference Sharma, Thomas and Foster25Reference Armellino, Trivedi and Law28 However, these strategies require financial resources, Reference Ellingson, Haas and Aiello18,Reference Haas and Larson19,Reference Sharma, Thomas and Foster25Reference Armellino, Trivedi and Law28 and the use of remote monitoring, product usage, or electronic counting devices alone without feedback resulted in low HHA rates. Reference Marra, Moura and Paes29Reference Wang, Jiang and Yang32 Only when individual feedback was provided did HH rates increase. Reference Armellino, Trivedi and Law28 Several technology systems are available to both provide real-time automated reminders to HCW to perform HH and collect adherence data remotely that is shared with the end-user. Reference Marra and Edmond30,Reference Cheng, Tai and Ho33Reference Radhakrishna, Waghmare and Ekstrand36 These automated hand hygiene reminder systems (AHHRSs) typically include wearable devices that provide a vibration, light, and/or audible sound to the user as a reminder to perform HH, Reference Cheng, Tai and Ho33Reference Radhakrishna, Waghmare and Ekstrand36 and some include alcohol sensors for detection of alcohol-based hand rub. Reference Edmond, Goodell, Zuelzer, Sanogo, Elam and Bearman35 Feasibility studies of AHHRS indicate low error rates and high rates of HH performance, in addition to the large numbers of HHO captured as compared to DO. Reference Sahud, Bhanot, Radhakrishnan, Bajwa, Manyam and Post37Reference McCalla, Reilly, Thomas and McSpedon-Rai40 HCW feedback for AHHRS optimal design and implementation include: (1) wearing a small and unobtrusive device for HH would demonstrate professional accountability, (2) the device should offer a vibratory or audible reminder to perform HH, (3) the device should capture opportunities around the patient’s physical location, (4) there should be a period of time to become accustomed to the device before performance measurement begins, (5) confidential audit and feedback of the user’s own performance should be provided, and (6) need for transparency regarding who would have access to adherence data and what the data would be used for in the form of clear policies and procedures prior to implementation. Reference Boscart, McGilton, Levchenko, Hufton, Holliday and Fernie41,Reference Meng, Sorber, Herzog, Igel and Kugler42 Previous reports of AHHRS implementation with end-user feedback as compared to DO demonstrate greater number of observations captured, Reference McCalla, Reilly, Thomas and McSpedon-Rai40,Reference Banks and Phillips43 lower adherence measurement due to the Hawthorne effect, Reference McCalla, Reilly, Thomas and McSpedon-Rai40 reduction in HAI, Reference Banks and Phillips43Reference Boyce, Laughman, Ader, Wagner, Parker and Arbogast45 and reduction in HCW sick days. Reference Strauch, Braun and Short46 However, there are no studies examining the unique impact of AHHRS-issued reminders on cross-contamination events (CCEs) over time.

We aim to assess the impact of a collaborative implementation strategy of AHHRS on overall HHA performance and potential CCEs in both a medical-surgical unit (MSU) and a medical intensive care unit (MICU). We hypothesize that engagement, education/training, data transparency, and optimization period will result in successful implementation and adoption of an AHHRS, HHA measurement with AHHRS will be lower than DO (due to the Hawthorne effect), HHA with the use of AHHRS will improve after baseline, and CCE will decrease over time with end-user feedback and real-time alerts.

Methods

Setting

This was a prospective, nonrandomized, before-after quality improvement feasibility pilot project conducted at NYC Health + Hospitals South Brooklyn Health, a 371-bed public hospital in New York City. Two units were identified for participation in the pilot: MSU and the MICU. These locations were chosen based on high rates of HAI in these areas of the hospital in the preceding year. As this was a quality improvement project, Institutional Review Board approval was not required.

Intervention and selection of AHHRS

A multidisciplinary team of nurses, physicians, infection-prevention specialists, educators, information-technology specialists, and environmental services associates (EVSs) assessed and selected an AHHRS platform. From September to December 2020, the team performed a risk/benefit analysis of existing AHHRS platforms, utilizing end-user feedback and feasibility, existing HH research studies, HAI outcome data, occupational safety data, data management process and security, opportunities for optimization and adjustment, costs, and expert opinion Reference Marra and Edmond30,Reference Wang, Jiang and Yang32,Reference McCalla, Reilly, Thomas and McSpedon-Rai40,Reference Meng, Sorber, Herzog, Igel and Kugler42Reference Strauch, Braun and Short46 to select the BioVigil AHHRS (BioVigil Technologies, Ann Arbor, MI) (Table 1).

Table 1. Risk/benefit analysis of BioVigil's automated hand hygiene reminder system

Note. HH, hand hygiene; HAI, hospital-acquired infection; CAUTI, catheter-associated urinary tract infection; CLABSI, central line-associated bloodstream infection.

BioVigil is an AHHRS that utilizes a wearable badge that provides vibration, audible, and visual reminders if HH is not detected within a specified time after entering or exiting a patient room or moving between patient zones. The badge communicates with beacons in doorways, at the head of patient beds, and with handwashing sinks when soap and water HH is required. The badge determines adequacy of HH based on sufficient alcohol concentration when using sanitizer, as well as duration spent at the handwashing sink when using soap and water. Data are collected in real time and transmitted virtually once the badge is placed back in a base station for charging (Figure 1). The badges are configurable to an institution’s HH policy, user feedback, role, location, and isolation status and include an exception function for emergencies or when HH is not required (eg, entering empty rooms). Configuration is performed at the time of installation, and isolation status is easily updated using a remote device that interfaces with the room beacon. Badges do not have location tracking capability or transmit information other than HH performance data. End-users receive feedback on their HH performance and badge utilization via email; other users can receive aggregated data as configured and determined by the institution’s policies. Color-changing badge indicators of adherence status empower patients in HHA.

Figure 1. BioVigil: how it works diagram.

Copyright © BioVigil LLC; Reproduced with permission.

The team developed an implementation plan based on the existing literature. Reference Larson, Early, Cloonan, Sugrue and Parides20,Reference Pittet, Hugonnet and Harbarth21,Reference Marra and Edmond30,Reference Meng, Sorber, Herzog, Igel and Kugler42,Reference Whitby, McLaws, Slater, Tong and Johnson47 The strategy included staff engagement ahead of AHHRS installation (March–July 2021), formal education and training (July 21–23, 2021), transparency on how and when data from the pilot would be shared with leaders and end-users (July 21–23, 2021), and a training period whereby users could practice using the device in advance of AHHRS data collection and provide recommendations for optimization of settings prior to formal go-live (July 21–July 31, 2021). A crossover period of 1 month during which both AHHRS and DO were utilized for HHA was included to ensure adequate HH monitoring occurred in the event of technical or other difficulties impacting data collection (August 1–31, 2021). After go-live (August 1, 2021), pilot participants received adherence status, CCE, and device utilization hours data biweekly by email. Leaders received weekly HHA reports, daily CCE reports, and monthly leadership overviews.

Pre-implementation engagement

Biweekly town hall meetings, daily unit-based huddles, biweekly leadership rounds, and two labor union meetings were conducted prior to the installation and training for the AHHRS beginning in March 2021. Staff were given written tip sheets about the AHHRS, and patients were given written information in admission packets about the pilot and how the AHHRS works. Data were shared on HAIs, and the difference between rates of HHA when staff was aware and unaware of observations. Information about the AHHRS was shared with all stakeholders as well as patients and caregivers, including the reasons for the pilot: protection of both staff and patients in the setting of COVID-19 and high HAI rates, and to ensure the system was acceptable to end-users and effective before adoption institution-wide.

Education and training

The AHHRS equipment was installed on July 19, 2021, and the system was configured to match the institution’s HH policy. The initial settings in the AHHRS allowed 90 seconds following entry to perform HH, 60 seconds grace period after room entry to exit a room without performing HH for the purposes of rounding without patient or environmental contact, and a minimum of 20 seconds at sinks for soap and water HH. Education took place through online module followed by in-person training. The online module consisted of a video describing the AHHRS purpose, functionality, and end-user workflow as well as a 13-question knowledge assessment with an agreed-upon passing score of 12 correct.

Data transparency

During training sessions, huddles, and rounds, staff was informed about exactly which data elements would be collected by the AHHRS, how often performance reports would be issued by email, how feedback reports would appear, and who would receive adherence data other than each individual end-user. Staff were assured that no punitive actions would be taken based on the pilot and the data collected by the AHHRS. Leaders subsequently utilized summary reports during the AHHRS pilot period to provide high-level feedback about unit performance, celebrate and award high-performers, and encourage staff to provide feedback about the AHHRS during daily huddles.

Optimization

Pilot participants began wearing and practicing use of the AHHRS badges from July 24 to July 31, 2021, prior to formal initiation of data collection. End-user recommendations to improve accuracy and usability were implemented prior to go-live.

Participants

HCWs in roles with the greatest patient contact and/or highest risk for contamination were included in the pilot: registered nurses (RNs), licensed practical nurses (LPNs), certified-nurse aides (CNAs), personal-care assistants (PCAs), physicians including trainees (MDs), physician assistants (PAs), respiratory therapists (RTs), and EVSs.

Variables and outcome variables

Staff member participation by role was quantified for the DO and AHHRS periods. During AHHRS implementation, educational opportunities, competency assessments, and changes to the AHHRS system based on staff feedback were described. HHO (patient room entry or room exit) and HHA (performance of appropriate HH upon room entry or exit) of HCW were quantified for the DO control (March–June 2021) and AHHRS intervention (September–December 2021) periods. Opportunities and adherence captured during the 1 month (August 2021) of crossover where both DO and AHHRS occurred were omitted from the comparative analysis of DO versus AHHRS measurement to allow for measuring the impact of each measure alone.

HHA during each biweekly period of the AHHRS pilot (August–December 2021) was measured as well as potential cross-contamination opportunities (CCOs) and CCE, and time to HHA after room exit. CCOs were defined as exit from one patient room without HHA followed by subsequent entry to another patient room; CCEs were defined as a CCO without HHA after entry into the second patient room.

Statistical analysis

Categorical variables were described as frequencies and percentages. The Pearson χ2 statistic compared the DO approach with the AHHRS approach for HHO participant categories and HHA. The McNemar test compared the baseline biweekly percentage to each of the additional 10 biweekly percentages for the AHHRS approach. The summary data were analyzed with immediate commands of tabi and mcci. Stata/SE Version 17 was used for the analyses (StataCorp, College Station, TX, 2021).

Results

Education and training

Over 92% (284/307) of participating staff members completed online training and passed the knowledge test. There were 5 live education sessions conducted daily from July 21 to 23, 2021, covering staff on all 3 shifts for 15 total sessions. The live sessions included how to endorse the device to capture HH events, time frames for the presence of alerts, when nonadherence is considered, workflow allowances such as emergencies, practice using the device, and teach-back demonstration. There were 75.2% (231/307) participating staff members who attended a live session, and the remainder were trained individually on the unit in the following week.

Optimization

Four leadership rounds and 16 huddles were conducted during the period between training and formal go-live where end-users were encouraged to provide feedback and recommendations. While users did not report interference with daily workflow, recommendations included adjusting settings to allow sufficient time for PPE donning, improving accuracy of beacon activation at handwashing sinks, and more frequent monitoring and refilling of hand sanitizer and soap dispensers by EVSs. The AHHRS settings and equipment were optimized based on staff feedback including extending entry time from 90 seconds to 120 seconds, changing the location of beacons above sinks for improved detection, and twice daily rounding of EVSs to refill hand sanitizer and soap dispensers. These changes were communicated with participating staff, empowering them as partners in the success of the pilot. Validation of DO and AHHRS confirmed that the recommended changes resulted in accurate capture of HHA.

Data collection and feedback

Distribution of HHO by Role

The distribution of HHOs and participation in the pilot program across HCW roles is provided in Table 2. The significance for observations comparisons (P < .001) showed that DO had a greater percentage for MD/PA and that AHHRS had a greater percentage for RN/LPN. There were 2,642 observations in the DO period versus 265,505 HHOs collected by the AHHRS; these AHHRS observations excluded any AHHRS observations collected during the crossover period in August 2021 where simultaneous DOs occurred.

Table 2. HH observation comparison and pilot participation by healthcare worker role

Note. Direct observation categories significantly differed from automated observation categories (P < .001).

Comparison of HHA between monitoring systems

Pearson χ2 comparisons for HHA between the DO and the AHHRS approaches where exclusively one observation approach was used are shown in Table 3. Overall HHA for DO (97.65%) was significantly greater compared to AHHRS (91.04%) (P < .001). In the MICU and the MSU, HHA for DO was significantly greater compared to AHHRS (98.65% vs 91.21%, P < .001 and 97.21% vs 90.99%, P < .001).

Table 3. HHA comparisons between direct observation and the AHHRS

Note. ICU, intensive care unit. Pearson χ2 analyses used for P value.

Change in HHO and HHA over time

Overall volume of the AHHRS HHO captured decreased over time from the first biweekly period to the last full biweekly period, which was the second-to-last biweekly period of weeks 19–20 (MICU: 12,315–4,678; MSU: 32,058–19,616). HHA biweekly percentages for the AHHRS period beginning from go-live in August are shown in Figure 2. For MICU, biweekly HHA was lowest during baseline weeks 1–2 (85.93%), highest during weeks 7–8 (92.91%), and a 5.31% greater percentage point during the last biweekly period (91.24%) than baseline. McNemar test comparisons from baseline to each additional 10 biweekly periods were all statistically significant (all P < .001); all 10 biweekly periods showed HHA significantly increased from baseline. For MSU, biweekly HHA was lowest during weeks 3–4 (85.15%), highest during weeks 19–20 (92.22%), and a 3.21% greater percentage point during the last biweekly period (89.68%) than baseline. McNemar test comparisons from baseline to each additional 10 biweekly percentages were all statistically significant (all P < .001). One biweekly period showed HHA significantly decreased from baseline, while 9 biweekly periods showed HHA significantly increased from baseline.

Figure 2. Percent HHA for the AHHRS.

Change in CCE over time

Figure 3 shows CCE for the AHHRS period beginning from go-live in August. For MICU, CCE during baseline weeks 1–2 was 81.22%. Using the McNemar test and compared from baseline, CCE significantly decreased (either P < .001, P < .01, or P < .05) for 8 biweekly periods. However, CCE for biweekly periods of weeks 11–12 and weeks 15–16 did not significantly differ from baseline. The last biweekly period of weeks 21–22 had CCE of 53.19% for a percentage point decrease of 28.03% from baseline. Although all biweekly time periods had decreased CCE from baseline, there were biweekly time periods where a decrease was followed by an increase in the next biweekly time period. For MSU, CCE during baseline weeks 1–2 was 73.42%. Using the McNemar test and compared from baseline, CCE significantly decreased for 7 biweekly periods (either P < .001 or P < .01). However, CCE for biweekly periods of weeks 13–14, weeks 17–18, and weeks 21–22 did not significantly differ from baseline. The last biweekly period of weeks 21–22 had a CCE of 65.11% for a percentage point decrease of 8.31% from baseline.

Figure 3. Percent cross-contamination for the AHHRS.

Time to HHA analysis

Time to HHA analysis for all room exit observations during the pilot period indicated that HH was most commonly performed within 9 seconds of exit, but a reminder after 15 seconds produced another spike in HH events in the first 24 seconds after exit, suggesting that the reminder produces a change in HH behavior (Figure 4). There were 34.70% (3,147/9,068) of potential CCE that occurred during the AHHRS period that were corrected after a badge reminder, potentially preventing pathogen transmission.

Figure 4. Time to HHA analysis for all room exit observations.

Discussion

We found support for our hypothesis that engagement, education/training, data transparency, and optimization period resulted in successful implementation and adoption of the AHHRS. Following successful implementation, AHHRS HHA improved from baseline, consistent with our hypothesis. Our observed HHA percentages of approximately 90% are similar to previous AHHRS studies, supporting the concept that automated reminders and feedback are effective in achieving high rates of HHA in different clinical settings. Reference Edmond, Goodell, Zuelzer, Sanogo, Elam and Bearman35,Reference McCalla, Reilly, Thomas and McSpedon-Rai40,Reference McCalla, Reilly, Thomas, McSpedon-Rai, McMahon and Palumbo44 We suggest that consistent real-time end-user feedback during patient care and reminders when HH is inadvertently missed result in high rates of HHA while using the AHHRS, as supported by the bimodal time-to-HHA analysis in our study. As hypothesized, we observed HHA measurement with AHHRS was lower than DO, this is most likely due to the known impact of the Hawthorne effect on DO-based measurements.

This study is the first to evaluate CCE using an AHHRS and to demonstrate an improvement in CCE over time. Reduction in CCE could be an underlying cause of the reduced HAI observed in other AHHRS studies, and further prospective study of this association is warranted. There was greater variation in biweekly CCE in the MICU than in the MSU. One potential reason is higher acuity of patients requiring rescue and failure to utilize the exception function on AHHRS badges; CCE variation in different clinical settings is an area for future investigation in the future.

We observed that RN/LPNs (69.09%) and CNA/PCAs (17.01%) had the most frequent AHHRS events, and MD/PAs (1.96%) and EVSs (1.06%) had the least frequent AHHRS events. We suggest that differences in frequency of room entry by role and exclusion of MD/PA and EVS staff who were not assigned to the unit consistently are responsible for these observed differences. Literature on DO showed similar differences in HHO by role Reference Pittet, Mourouga and Perneger6 ; this could be an area for further investigation using AHHRS.

Cost of AHHRS and other technology-assisted HH monitoring strategies is a limitation to widespread adoption and implementation. Reference Ellingson, Haas and Aiello18,Reference Wang, Jiang and Yang32 However, DO programs have high costs too. At our institution, to meet Leapfrog (an advocacy group for healthcare safety), HHO requirements (200 observations per unit monthly) 48 , at an estimated 10 minutes per event and 16 clinical units, require an estimated 533 hours of employee time monthly. Reference Pittet, Boyce and Allegranzi49 Data entry and analysis, report generation, and data distribution are another estimated 5 hours per unit monthly, adding an additional 80 hours of employee time monthly. This is approximately 613 hours of employee time monthly for DO. The cost (based on $37.50/h average hourly compensation rate for nurses performing these observations) 50 is $22,987.50 monthly, or $275,850 yearly for our DO program. Furthermore, multimodal HH strategies using AHHRS improve HHA rates and reduce HAI. Reference Banks and Phillips43Reference Boyce, Laughman, Ader, Wagner, Parker and Arbogast45 Cost savings from HAI reductions should be included in financial analysis of AHHRS. Prior studies of AHHRS demonstrate a 45% reduction in central line-associated bloodstream infection, Reference McCalla, Reilly, Thomas, McSpedon-Rai, McMahon and Palumbo44 55% reduction in catheter-associated urinary tract infection, Reference McCalla, Reilly, Thomas, McSpedon-Rai, McMahon and Palumbo44 and 38% reduction in Clostridioides difficile infection. Reference Banks and Phillips43

Our quality improvement project had several limitations and practical challenges. First, the intervention was not designed to measure changes in clinical outcomes, HAI, or employee illness. Second, there was a decrease in AHHRS utilization over time. It is likely that staff turnover, increase in agency staff during COVID-19 surges, and rotation of nurses and housestaff to different units or hospitals impacted utilization; future studies should formally evaluate utilization over time by measuring HCW-specific events. Third, a randomized prospective study design with a longer trial period, more data points, and more disciplines included would provide greater clarity and depth of knowledge regarding changes in behavior with AHHRS. Fourth, double-bedded rooms posed challenges in accurate capturing of HHO, despite changes in position of beacons to reduce inconsistencies. Lastly, our analysis did not include potential employee illness reduction cost savings or avoidance of Centers for Medicare and Medicaid Services penalties through the hospital-acquired condition reduction program or related programs, likely underestimating true return-on-investment for AHHRS implementation.

In conclusion, an AHHRS approach was successfully implemented at our healthcare facility. With ongoing feedback and system optimization, AHHRS improved HHA and reduced CCE over time.

Acknowledgments

Kevin Fehily: Planning and installation of the AHHRS.

Michael Kay: Security review and IT configuration.

Svetlana Lipyanskaya, MPA: Executive sponsorship.

Dianna Jacob, PA, MBA: Executive sponsorship and manuscript review.

Martha Braverman: Training and data support.

Scott Jeffery: Contracting and data support.

Author contribution

All authors have significantly contributed to this work consistent with the CRediT taxonomy.

Financial support

New York City Health and Hospitals contracted with BioVigil Healthcare Systems, Inc. for the pilot data described in this manuscript. There were no other sources of financial support for this work.

Competing interests

The authors report no conflicts of interest.

References

Magill, SS, O’Leary, E, Janelle, SJ, et al. Changes in prevalence of health care-associated infections in U.S. hospitals. N Engl J Med 2018;379:17321744.CrossRefGoogle ScholarPubMed
Magill, SS, Edwards, JR, Bamberg, W, et al. Multistate point-prevalence survey of health care-associated infections. N Engl J Med 2014;370:11981208.CrossRefGoogle ScholarPubMed
Scott, RD II. The Direct Medical Costs of Healthcare-associated Infections in U.S. Hospitals and the Benefits of Prevention. 2009. https://www.cdc.gov/hai/pdfs/hai/scott_costpaper.pdf. Accessed January 3, 2023.Google Scholar
World Health Organization. WHO Guidelines on Hand Hygiene in Health Care: First Global Patient Safety Challenge Clean Care Is Safer Care. 2009. https://www.who.int/publications/i/item/9789241597906. Accessed January 3, 2023.Google Scholar
Gould, DJ, Moralejo, D, Drey, N, Chudleigh, JH, Taljaard, M. Interventions to improve hand hygiene compliance in patient care. Cochrane Database Syst Rev 2017;9:Cd005186.Google ScholarPubMed
Pittet, D, Mourouga, P, Perneger, TV. Compliance with handwashing in a teaching hospital. Infection Control Program. Ann Intern Med 1999;130:126130.CrossRefGoogle Scholar
Kingston, L, O’Connell, NH, Dunne, CP. Hand hygiene-related clinical trials reported since 2010: a systematic review. J Hosp Infect 2016;92:309320.CrossRefGoogle ScholarPubMed
Sanderson, PJ, Weissler, S. Recovery of coliforms from the hands of nurses and patients: activities leading to contamination. J Hosp Infect 1992;21:8593.CrossRefGoogle ScholarPubMed
McFarland, LV, Mulligan, ME, Kwok, RY, Stamm, WE. Nosocomial acquisition of Clostridium difficile infection. N Engl J Med 1989;320:204210.CrossRefGoogle ScholarPubMed
Samore, MH, Venkataraman, L, DeGirolami, PC, Arbeit, RD, Karchmer, AW. Clinical and molecular epidemiology of sporadic and clustered cases of nosocomial Clostridium difficile diarrhea. Am J Med 1996;100:3240.CrossRefGoogle ScholarPubMed
Duckro, AN, Blom, DW, Lyle, EA, Weinstein, RA, Hayden, MK. Transfer of vancomycin-resistant enterococci via health care worker hands. Arch Intern Med 2005;165:302307.CrossRefGoogle ScholarPubMed
McBryde, ES, Bradley, LC, Whitby, M, McElwain, DL. An investigation of contact transmission of methicillin-resistant Staphylococcus aureus. J Hosp Infect 2004;58:104108.CrossRefGoogle ScholarPubMed
Sakamoto, F, Yamada, H, Suzuki, C, Sugiura, H, Tokuda, Y. Increased use of alcohol-based hand sanitizers and successful eradication of methicillin-resistant Staphylococcus aureus from a neonatal intensive care unit: a multivariate time series analysis. Am J Infect Control 2010;38:529534.CrossRefGoogle ScholarPubMed
Tian, C, Lovrics, O, Vaisman, A, et al. Risk factors and protective measures for healthcare worker infection during highly infectious viral respiratory epidemics: a systematic review and meta-analysis. Infect Control Hosp Epidemiol 2022;43:639650.CrossRefGoogle ScholarPubMed
Hall, CB, Douglas, RG, Jr. Modes of transmission of respiratory syncytial virus. J Pediatr 1981;99:100103.CrossRefGoogle Scholar
The Joint Commission. Measuring Hand Hygiene Adherence: Overcoming the Challenges. 2009. https://www.jointcommission.org/-/media/tjc/documents/resources/hai/hh_monograph.pdf. Accessed January 3, 2023.Google Scholar
Boyce, JM, Pittet, D. Guideline for hand hygiene in health-care settings. Recommendations of the Healthcare Infection Control Practices Advisory Committee and the HICPAC/SHEA/APIC/IDSA Hand Hygiene Task Force. Society for Healthcare Epidemiology of America/Association for Professionals in Infection Control/Infectious Diseases Society of America. MMWR Recomm Rep 2002;51:145, quiz CE41-44.Google ScholarPubMed
Ellingson, K, Haas, JP, Aiello, AE, et al. Strategies to prevent healthcare-associated infections through hand hygiene. Infect Control Hosp Epidemiol 2014;35:937960.CrossRefGoogle ScholarPubMed
Haas, JP, Larson, EL. Measurement of compliance with hand hygiene. J Hosp Infect 2007;66:614.CrossRefGoogle ScholarPubMed
Larson, EL, Early, E, Cloonan, P, Sugrue, S, Parides, M. An organizational climate intervention associated with increased handwashing and decreased nosocomial infections. Behav Med 2000;26:1422.CrossRefGoogle ScholarPubMed
Pittet, D, Hugonnet, S, Harbarth, S, et al. Effectiveness of a hospital-wide programme to improve compliance with hand hygiene. Infection Control Programme. Lancet 2000;356:13071312.CrossRefGoogle ScholarPubMed
Hagel, S, Reischke, J, Kesselmeier, M, et al. Quantifying the Hawthorne effect in hand hygiene compliance through comparing direct observation with automated hand hygiene monitoring. Infect Control Hosp Epidemiol 2015;36:957962.CrossRefGoogle ScholarPubMed
Srigley, JA, Furness, CD, Baker, GR, Gardam, M. Quantification of the Hawthorne effect in hand hygiene compliance monitoring using an electronic monitoring system: a retrospective cohort study. BMJ Qual Saf 2014;23:974980.CrossRefGoogle ScholarPubMed
Pan, SC, Tien, KL, Hung, IC, et al. Compliance of health care workers with hand hygiene practices: independent advantages of overt and covert observers. PLoS One 2013;8:e53746.CrossRefGoogle ScholarPubMed
Sharma, D, Thomas, GW, Foster, ED, et al. The precision of human-generated hand-hygiene observations: a comparison of human observation with an automated monitoring system. Infect Control Hosp Epidemiol 2012;33:12591261.CrossRefGoogle ScholarPubMed
Hlady, CS, Severson, MA, Segre, AM, Polgreen, PM. A mobile handheld computing application for recording hand hygiene observations. Infect Control Hosp Epidemiol 2010;31:975977.CrossRefGoogle ScholarPubMed
Chen, LF, Carriker, C, Staheli, R, et al. Observing and improving hand hygiene compliance: implementation and refinement of an electronic-assisted direct-observer hand hygiene audit program. Infect Control Hosp Epidemiol 2013;34:207210.CrossRefGoogle ScholarPubMed
Armellino, D, Trivedi, M, Law, I, et al. Replicating changes in hand hygiene in a surgical intensive care unit with remote video auditing and feedback. Am J Infect Control 2013;41:925927.CrossRefGoogle Scholar
Marra, AR, Moura, DF, Jr., Paes, AT, dos Santos OF, Edmond MB. Measuring rates of hand hygiene adherence in the intensive care setting: a comparative study of direct observation, product usage, and electronic counting devices. Infect Control Hosp Epidemiol 2010;31:796801.CrossRefGoogle ScholarPubMed
Marra, AR, Edmond, MB. Hand hygiene: state-of-the-art review with emphasis on new technologies and mechanisms of surveillance. Curr Infect Dis Rep 2012;14:585591.CrossRefGoogle ScholarPubMed
McGuckin, M, Waterman, R, Govednik, J. Hand hygiene compliance rates in the United States--a one-year multicenter collaboration using product/volume usage measurement and feedback. Am J Med Qual 2009;24:205213.CrossRefGoogle ScholarPubMed
Wang, C, Jiang, W, Yang, K, et al. Electronic monitoring systems for hand hygiene: systematic review of technology. J Med Internet Res 2021;23:e27880.CrossRefGoogle ScholarPubMed
Cheng, VC, Tai, JW, Ho, SK, et al. Introduction of an electronic monitoring system for monitoring compliance with Moments 1 and 4 of the WHO “My 5 Moments for Hand Hygiene” methodology. BMC Infect Dis 2011;11:151.CrossRefGoogle ScholarPubMed
Polgreen, PM, Hlady, CS, Severson, MA, Segre, AM, Herman, T. Method for automated monitoring of hand hygiene adherence without radio-frequency identification. Infect Control Hosp Epidemiol 2010;31:12941297.CrossRefGoogle ScholarPubMed
Edmond, MB, Goodell, A, Zuelzer, W, Sanogo, K, Elam, K, Bearman, G. Successful use of alcohol sensor technology to monitor and report hand hygiene compliance. J Hosp Infect 2010;76:364365.CrossRefGoogle ScholarPubMed
Radhakrishna, K, Waghmare, A, Ekstrand, M, et al. Real-time feedback for improving compliance to hand sanitization among healthcare workers in an open layout ICU using radiofrequency identification. J Med Syst 2015;39:68.CrossRefGoogle Scholar
Sahud, AG, Bhanot, N, Radhakrishnan, A, Bajwa, R, Manyam, H, Post, JC. An electronic hand hygiene surveillance device: a pilot study exploring surrogate markers for hand hygiene compliance. Infect Control Hosp Epidemiol 2010;31:634639.CrossRefGoogle ScholarPubMed
Levchenko, AI, Boscart, VM, Fernie, GR. The feasibility of an automated monitoring system to improve nurses’ hand hygiene. Int J Med Inform 2011;80:596603.CrossRefGoogle ScholarPubMed
Levchenko, AI, Boscart, VM, Fernie, GR. The effect of automated monitoring and real-time prompting on nurses’ hand hygiene performance. Comput Inform Nurs 2013;31:498504.CrossRefGoogle ScholarPubMed
McCalla, S, Reilly, M, Thomas, R, McSpedon-Rai, D. An automated hand hygiene compliance system is associated with improved monitoring of hand hygiene. Am J Infect Control 2017;45:492497.CrossRefGoogle ScholarPubMed
Boscart, VM, McGilton, KS, Levchenko, A, Hufton, G, Holliday, P, Fernie, GR. Acceptability of a wearable hand hygiene device with monitoring capabilities. J Hosp Infect 2008;70:216222.CrossRefGoogle ScholarPubMed
Meng, M, Sorber, M, Herzog, A, Igel, C, Kugler, C. Technological innovations in infection control: a rapid review of the acceptance of behavior monitoring systems and their contribution to the improvement of hand hygiene. Am J Infect Control 2019;47:439447.CrossRefGoogle Scholar
Banks, M, Phillips, AB. Evaluating the effect of automated hand hygiene technology on compliance and C. difficile rates in a long-term acute care hospital. Am J Infect Control 2021;49:727732.CrossRefGoogle Scholar
McCalla, S, Reilly, M, Thomas, R, McSpedon-Rai, D, McMahon, LA, Palumbo, M. An automated hand hygiene compliance system is associated with decreased rates of health care-associated infections. Am J Infect Control 2018;46:13811386.CrossRefGoogle ScholarPubMed
Boyce, JM, Laughman, JA, Ader, MH, Wagner, PT, Parker, AE, Arbogast, JW. Impact of an automated hand hygiene monitoring system and additional promotional activities on hand hygiene performance rates and healthcare-associated infections. Infect Control Hosp Epidemiol 2019;40:741747.CrossRefGoogle ScholarPubMed
Strauch, J, Braun, TM, Short, H. Use of an automated hand hygiene compliance system by emergency room nurses and technicians is associated with decreased employee absenteeism. Am J Infect Control 2020;48:575577.CrossRefGoogle ScholarPubMed
Whitby, M, McLaws, ML, Slater, K, Tong, E, Johnson, B. Three successful interventions in health care workers that improve compliance with hand hygiene: is sustained replication possible? Am J Infect Control 2008;36:349355.CrossRefGoogle ScholarPubMed
Leapfrog Group. Leapfrog Hospital Survey Factsheet: Hand Hygiene. 2020. https://ratings.leapfroggroup.org/sites/default/files/2020-08/2020-Hand-Hygiene-Fact-Sheet.pdf. Accessed January 3, 2023.Google Scholar
Pittet, D, Boyce, J, Allegranzi, B. Hand Hygiene: A Handbook for Medical Professionals . Chichester West Sussex UK: John Wiley & Sons; 2016.CrossRefGoogle Scholar
US Bureau of Labor Statistics. Occupational Outlook Handbook. 2021. https://www.bls.gov/ooh/healthcare/registered-nurses.htm. Accessed October 11, 2022.Google Scholar
Figure 0

Table 1. Risk/benefit analysis of BioVigil's automated hand hygiene reminder system

Figure 1

Figure 1. BioVigil: how it works diagram.Copyright © BioVigil LLC; Reproduced with permission.

Figure 2

Table 2. HH observation comparison and pilot participation by healthcare worker role

Figure 3

Table 3. HHA comparisons between direct observation and the AHHRS

Figure 4

Figure 2. Percent HHA for the AHHRS.

Figure 5

Figure 3. Percent cross-contamination for the AHHRS.

Figure 6

Figure 4. Time to HHA analysis for all room exit observations.