Introduction
Drifting snow is significant for the mass budget of the Antarctic ice cap. For example, the estimated amount of 109 kg km−1 a−1 at Mizuho Station (Reference KobayashiKobayashi 1978) is not small compared with the mass transport by ice-sheet flow. Now that improved mass-transportation models are available, accurate flux measurements become increasingly important. Until now measurements of drifting snow have employed almost exclusively the principle of trapping the wind-blown snow particles. A great variety of slit-type, cyclone-type, and rocket-type collectors have been used (Reference Budd, Dingle, Radok and RubinBudd and others 1966). The many shapes and sizes of these traps have different degrees of efficiency and make it difficult to compare the results. For flux measurements the collected snow must be weighed at regular time intervals. The final drift transport, obtained from integration of drift flux, must be measured at different levels above ground. Drift densities, sometimes needed for models, are derived from flux values if the wind velocity is known at the corresponding level.
Whereas the use of snow traps is rather cumbersome, a real-time processing optical system was designed by Reference SchmidtSchmidt (1977). It measures the number, velocity, and size of snow particles through a double-beam light pass, but can only be used at counting rates less than 1 kHz. Since the optical properties of snow particles differ widely with shape and size, the device must be carefully calibrated.
This paper describes an alternative small-size, new type of sensor for continuous observation of drift flux in real time over long periods.
Instrumentation
The detector is based on the momentum transfer of individual snow particles to a sensitive surface. Each impact is transformed into a single-voltage pulse proportional to the mass and velocity of the particle. The momentum spectrum is displayed in real time by a computer-controlled multi-channel analyzer system.
Sensor head
The sensor head, shown in Figure 1a, consists of two ceramic cylinders 10 mm long and 4 mm in diameter, which are mounted symmetrically about a small piezo crystal. A particle impact to the front surface produces longitudinal oscillations of the frequency
where c is the sound velocity (4700 m/s) and l is the total cylinder length (20.5 mm). These sonic oscillations are converted to electrical oscillations by the crystal. As the crystal is positioned at the nodal point of the basic oscillation (n = 1), it shows a maximum signal amplitude for the second harmonic (n = 2) at 230 kHz. For the chosen dimensions of the cylinder, higher harmonics were not observed. The resonance frequency was independent of particle mass and velocity. For good conductivity the inner half of the cylinder area is covered with a thin layer of chromium and gold. The main problem was to get only one small, well-shaped voltage pulse from a sensor oscillation, which had a time constant of about 80 μs (18 Hz). To avoid multiple counting of the same event, the damping had to be increased. This was achieved by covering the central part of the cylinder with a thin layer of indium. The time constant could be reduced to about 8 μs without significant loss of sensitivity. Compared to many other materials, indium was found to be best suited to our application. It ensures that the time constant remains unchanged at least down to the temperature of −30°C at which the sensor was tested. The measurements will be continued in a cold-room down to −60°C.
Electronics
The sensor housing (Fig. 1b) contains a two-stage amplifier and current booster for cable transmission. The negative pulse of a particle event is amplified and inverted to a positive signal. Because of the short time constant of the sensor head and the insensitivity of the first amplifier to positive voltage, the final detector output is a single pulse in the range 0–10 V. The width and shape of the pulse correspond to the first negative half-wave of the original 230 kHz oscillation. The sensor electronics operate at temperatures down to −55°C.
The data processing is shown in the block diagram of Figure 1c (a similar technique is also used for nuclear spectroscopy). The events are counted in 4096 separate channels as a function of pulse height and displayed in real time. Several mathematical functions can easily be applied to the momentum distribution. For example, the drift flux is computed from the integral of the spectrum, if the mean particle velocity is taken from separate wind measurements. The electronic equipment is placed in a 19 in housing of about 20 kg. The largest component is a multi-channel analyzer, type 7450, from EG&E Ortec.
Measurements
Typical snow-drift particles have a size of 50–150 μm and are out of round by less than a factor of 3 (Budd and others 1966). Adopting a weight ratio of 50 for large particles in relation to small ones (Reference Ishimoto and TakeuchiIshimoto and Takeuchi 1984) and a velocity range from 5 to 30 m/s, the dynamic range of the sensor should be at least 300, which corresponds to pulse heights from 0.03 to 10.0 V.
The calibration of the sensor under real field conditions is rather difficult, because the mass and velocity distribution of the particles need to be well known. For laboratory measurements, therefore, the snow was replaced by small grains of sand. As the detector is sensitive to particle momentum only, for easier operation the mass was increased and the velocity decreased relative to field conditions. Particles used for the experiment had a mass of 0.2–2.0 mg and a diameter of 0.3–0.8 mm. Individual grains were weighed in a highly sensitive balance to an accuracy of ±2 × 10−5 g and were dropped on to the sensor surface from heights between 2 and 20 cm. Under these conditions the correction for air friction, derived from Stokes' law, was 1–4% of gravitational forces. The measured pulse height was found to be proportional to the fall velocity, as shown in Figure 2. Particles of different mass, which were dropped from a constant height (v = 1.4 m/s), showed the same linearity (Fig.3). Consequently, the pulse height must be proportional to the root of the particle momentum. The amplifier sensitivity was reduced by 25 dB to keep the input voltage for the pulse analyzer below 10 V.
An uncalibrated version of this device was tested during an Antarctic expedition in September 1986. The sensor was mounted on a ship, about 15 m above sea-ice level. A momentum spectrum obtained during a snow-storm with a wind speed of 17 m/s is shown in Figure 4. An explanation for the two peaks in the spectrum might be provided by a different mass distribution of drift and precipitation particles. An accumulation of snow particles at the sensor surface was not observed. Ice crystals resulting from sublimation were only found once at the sensor edge, when the humidity was high and the temperature close to 0°C.
Errors
The laboratory experiments show that the momentum of single particles can be measured with an accuracy of about 5%. Errors were introduced mainly by the uncertainty of particle mass, air friction, and center-to-edge effects of the sensor. The particle shape had no significant influence on the pulse height. Only particles of an extreme shape (needles, discs) showed asymmetrical pulses of varying height, because their impact was not well defined.
For field measurements additional systematic errors become important. One source of error is the effective cross-section (intersecting area / physical area) of the sensor head, due to changes in the trajectories of snow particles before their impact. From the wind profile close to the sensor, the cross-section was estimated to be about 0.95 for particles of 5 m/s and 100 μm in diameter. The cross-section mainly depends on particle mass and decreases for smaller particles.
Another error arises from variation in snow hardness as a function of temperature. The destruction of particles during the impact might have an influence on the pulse height.
As the measurement is based on pulse-counting technique, dead-time corrections become important with increasing counting rate. With a dead time of 10 μs for the drift sensor, the correction is 1% at 1 kHz. At the expected maximum of about 10 kHz, derived from flux observations at Mizuho Station (Reference Takahashi, Ohmae, Ishikawa, Katsushima and NishioTakahashi and others 1984), the correction would increase to 10%.
Conclusions
The method described looks quite promising for measuring the flux of drifting snow. The sensor can be used to build up larger arrays for drift-transport measurements. It is small in size and can easily be placed in the saltation layer, close to the ground. The calibration procedure will be continued in a wind tunnel, using smaller particles at higher velocities. We are going to integrate into one unit the drift detector and solid-state sensors for wind-speed and wind-direction measurements.
Acknowledgement
The author wishes to express his thanks to Dr G. Gravenhorst for his help in solving some hydrodynamic problems.