Abstract

Scanning x-ray fluorescence microscopy is analogous to scanning electron microscopy. Maps of the distribution of chemical elements are produced by scanning the specimen with a very small x-ray beam while collecting the XRF spectrum. Our goal is to perform such scanning microscopy with resolution in the range of <1 to 10 μm, using standard laboratory x-ray tubes. In order to increase the radiation flux on the specimen, we are investigating mirror optics in the Kirkpatrick-Baez (K-B) configuration, K-B optics uses two curved mirrors mounted orthogonally along the optical axis. The first mirror provides vertical focus, the second mirror provides horizontal focus. We have used two types of mirrors: synthetic multilayers and crystals. Multilayer mirrors are used with lower energy radiation such as Cu Kμ. At higher energies such as Ag Kct, silicon wafers are used in order to increase the incidence angles and thereby the photon collection efficiency. In order to increase the surface area of multilayers which reflects x-rays at the Bragg angle, we have designed mirrors with the spacing between layers graded along the optic axis in order to compensate for the changing angle of incidence. Likewise, to achieve a large reflecting surface with silicon, the wafers are placed on a specially designed lever arm which is bent into a log spiral by applying force at one end. In this way, the same diffracting angle is maintained over the entire surface of the wafer, providing a large solid angle for photon collection.

Type
XV. X-Ray Imaging and Tomography
Copyright
Copyright © International Centre for Diffraction Data 1991

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Gurker, N., “Imaging Techniques for X-Ray Fluorescence and X-Ray Diffraction”, Advances in X-Ray Analysis, Vol. 30, (1987), pp. 5365.Google Scholar
2. Nichols, Monte C., Boehme, Dale R., Ryon, Richard W., Wherry, David, Cross, Brian, and Aden, Gary, “Parameters Affecting X-Ray Microfluorescence (XRMP) Analysis”, Advances in X-Ray Analysis, vol. 30 (1987), pp. 4551.Google Scholar
3. Larsson, S., Engstrom, P., and Rindby, A., “X-Ray Capillary Microbeam Spectrometer”, Advances in X-Ray Analysis, Vol. 33, (1990), pp. 623628.Google Scholar
4. Carpenter, D. A., Taylor, M. A., and Holcombe, C. E., “Applications of a Laboratory X-Ray Microprobe to Materials Analysis”, Advances in X-Ray Analysis, vol. 32 (1989), pp. 115120.Google Scholar
5. Kumakhov, Muradin and Gibson, Walter, as reported in “Piping X-Rays Through a Glass Brightly”, Science, vol. 252 (12 April 1991), pp. 208209.Google Scholar
6. Niemann, B., Schmahl, G., et al., “X-Ray Microscopy with Synchrotron Radiation at the Electron Storage Ring BESSY in Berlin”, Nuclear Instruments and Methods in Physics Research A246 (1986), pp. 675680.Google Scholar
7. Bionta, Richard M., Skulina, Kenneth M., et al., “Tabletop X-ray Microscope Using 8 keV Zone Plates”, Optical Engineering, Vol. 29, No. 6 (1990), p 576.Google Scholar
8. Kirkpatrick, Paul and Baez, A. V., “Formation of Optical Images by X-Rays”, Journal of the Optical Society of America, vol. 38, No. 9 (1948), pp. 766774.Google Scholar
9. Underwood, J. H., Thompson, A. C., Wu, Y. and Giauque, R. D., “XRay Microprope Using Multilayer Mirrors”, Nuclear Instruments and Methods in Physics Research A266 (1988), pp. 296302.Google Scholar
10. The multilayer code we use is an adaptation by Barry Jocoby of the Lawrence Livermore National Laboratory of a code by Underwood and Barbee. See James H. Underwood and Troy W. Barbee, Jr., “Synthetic Multilayers as Bragg Diffractors for X-Rays and Extreme Ultraviolet : Calculations and Performance”, American Institute of Physics Conference Proceedings Number 75, Low Energy X-Ray Diagnostics-1981, pp. 170-178.Google Scholar