Generation of 1-10 Ps Hard X-Rav Pulses for Time Resolved X-Ray Diffraction
Published online by Cambridge University Press: 06 March 2019
Abstract
We present a further improvement of our experimental system for the generation of hard x-ray pulses in the range 1-10 ps, A laser system based on a cw mode locked Nd:YLF laser is utilized for the emission of deep UV pulses at 193 nm with duration 1.5 ps and repetition rate of 300 Hz, This UV radiation is used to pump an x-ray diode which produces CuKa x-ray pulses with a duration shorter than 10 ps at 300 Hz.
- Type
- Research Article
- Information
- Copyright
- Copyright © International Centre for Diffraction Data 1995
References
Kmetec, J. D., Gordon, C. L., III, Macklin, J. J., Lemoff, B. E., Brown, G. S., and Harris, S. E, Phys. Rev. Lett., 86, 1527 (1992).Google Scholar
4.
Tomov, L. V., Anderson, T. and Rentzepis, P. M., J. X-ray Sci. Technol., 4, 44 (1993).Google Scholar
6.
Girardeau-Montaut, C., Girardeau-Montaut, J. P. and Leboutet, H., Appl, Phys, Lett, 55, 2556 (1989).Google Scholar
7.
Tomov, I. V., Anderson, T., and Rentzepis, P. M., Appl, Phys. Lett.
61, 1157 (1992); 61, 3193E (1992).Google Scholar
8.
Dyson, N. A., “X-ray in atomic and nuclear physics”, Cambridge Univrsity Press, 1990.Google Scholar