Summary

Optical Imaging

Optical imaging has been used by countless species since the evolution of the eye. It is used as a critical observational technique in assessing the skin of patients by dermatologists. It is used for internal examination by endoscopists. However, following the invention of the microscope in the late 1500s, optical imaging began to be extended to much smaller objects. The capabilities of the microscope have evolved over the recent centuries, with many different approaches, such that it is impossible to fully review optical microscopy in a brief chapter. The major focus of this chapter is fluorescent and bioluminescent imaging in small animals, and when feasible in humans. A recent textbook that covers the subject area in greater depth is Biomedical Optical Imaging. The reader can also find an excellent review of general microscopy in Wikipedia and of optical microscopy at the Olympus Microscopy Research Center.

Fundamental Issues

As photons propagate through tissue, they are attenuated and scattered. The degree of attenuation and scattering depends on the wavelength of the light and the characteristics of the tissue being imaged. In most animals, including humans, a major determinate of the absorption of light is hemoglobin. Visible light extends from 380 nm (deep violet) to 750 nm (dark red). Hemoglobin absorbs markedly from about 500 nm to 600 nm, with significant difference in absorption between oxygenated and deoxygenated hemoglobin. Above 600 nm, extending into the near infrared, the absorption is much less, allowing penetration of photons to several millimeters or even centimeters. This illustrates why near infrared imaging is the favored part of the spectrum to use for in-vivo optical imaging.

Fluorescence Imaging

The essential elements of fluorescence imaging are: (1) existence of a fluorescent molecule within tissue that has localized there by bulk flow (i.e. blood vessels or lymphatics), binding to a receptor, or metabolic trapping; (2) illumination of the tissue with a light source of appropriate wavelength, which excites the fluorescent molecule; and (3) a detection system that can image the emitted light from the fluorescent molecule.

Type
Chapter
Information
Molecular Imaging
An Introduction
, pp. 16 - 18
Publisher: Cambridge University Press
Print publication year: 2017

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Fujimoto, JG, Farkas, DL, Eds. Biomedical Optical Imaging, Oxford University Press, 2009 New York.Google Scholar
2. www.olympusmicro.com/primer/opticalmicroscopy
3. Polom, K, Murawa, D, Rho, YS, Nowaczyk, P, Hünerbein, M, Murawa, P. Current trends and emerging future of indocyanine green usage in surgery and oncology: a literature review. Cancer. 2011 Nov 1;117(21):4812–22.CrossRefGoogle Scholar
4. Sevick-Muraca, EM. Translation of near-infrared fluorescence imaging technologies: emerging clinical applications. Annu Rev Med. 2012; 63:217–31.CrossRefGoogle ScholarPubMed
5. Ntziachristos, V, Bremer, C, Weissleder, R. Fluorescence imaging with near-infrared light: new technological advances that enable in vivo molecular imaging. Eur Radiol. 2003 Jan;13(1):195–208.Google ScholarPubMed
6. O'Neill, K, Lyons, SK, Gallagher, WM, Curran, KM, Byrne, AT. Bioluminescent imaging: a critical tool in pre-clinical oncology research. J Pathol. 2010 Feb;220(3):317–27.Google ScholarPubMed
7. Xia, J, Wang, LV. Small-animal whole-body photoacoustic tomography: a review. IEEE Trans Biomed Eng. 2014 May;61(5):1380–9.Google ScholarPubMed
8. Foster, FS, Cheung, K, Cherin, E. Ultrasound. In: Molecular Imaging-Principles and Practice. Weissledder, R, Ross, BD, Rehemtulla, A, Gambhir, SS (Eds.). People's Medical Publishing House, Shelton, CT, 2010. pp. 225–36.Google Scholar
9. Wen, Q, Wan S, Liu Z, Xu S, Wang H, Yang B. Ultrasound contrast agents and ultrasound molecular imaging. J Nanosci Nanotechnol 2014; 14:190–209.CrossRefGoogle ScholarPubMed
10. Hyvelin, JM, Tardy I, Arbogast C, Costa M, Emmel P, Helbert A, et al. Use of ultrasound contrast agents in preclinical research: recommendations for small animal imaging. Invest Radiol 2013; 48:570–83.CrossRefGoogle ScholarPubMed
11. Lin, Y, Chen, ZY, Yang, F. Ultrasound-based multimodal molecular imaging and functional ultrasound contrast agents. Curr Pharm Des 2013; 19:3342–51.CrossRefGoogle ScholarPubMed
12. Unnikrishnan, S, Kilbanov, AL. Microbubbles as ultrasound contrast agents for molecular imaging. Preparation and application. AJR Am J Roentgenol 2012; 199:292–9.CrossRefGoogle ScholarPubMed
13. Kiessling, F, Bzyl J, Fokong S, Siepmann M, Schmitz G, Palmowski M. Targeted ultrasound imaging of cancer: an emerging technology on its way to the clinic. Curr Pharm Des 2012; 18:2184–99.CrossRefGoogle Scholar

Save book to Kindle

To save this book to your Kindle, first ensure [email protected] is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats No formats are currently available for this content.
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats No formats are currently available for this content.
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats No formats are currently available for this content.
×