We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
The control of patient position, posture and respiratory movements during radiotherapy is important for effective and specific treatment of malignancy. We have developed an infrared (IR) interactive patient position guidance and acquisition control system for clinical use, comprising IR cameras, IR markers and dedicated software.
Materials and methods
We evaluated the system with ten healthy volunteers and ten experienced operators. IR markers were placed on the body surface. Their positions were calculated using vectors of three translational and three rotational parameters, and the intrafractional error for each marker was acquired with and without respiratory motion. The inclusion of multiple positioning markers allowed for real-time visualisation of the patient posture, with feedback on misalignment and required postural adjustments.
Results
The positioning time was 73 seconds (with a minimum period of 39 seconds), which was significantly shorter than for conventional line alignment. A comparison of positioning reproducibility between conventional line alignment and this system was <3·5 mm and was not patient dependent or operator dependent. An intrafractional error of displacement of up to 10·0 mm was found in the right iliac crest.
Conclusions
This IR interactive system was shown to be high utility and suitable for monitoring patient position, posture and respiratory movements during radiotherapy.