The aim of the study was to estimate the sensitivity and specificity of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for detecting antibodies of Neospora caninum in dairy cows, in the absence of a gold standard. The study complies with STRADAS-paratuberculosis guidelines for reporting the accuracy of the test. We tried to apply Bayesian models that do not require conditional independence of the tests under evaluation, but as convergence problems appeared, we used Bayesian methodology, that does not assume conditional dependence of the tests. Informative prior probability distributions were constructed, based on scientific inputs regarding sensitivity and specificity of the IB test and the prevalence of disease in the studied populations. IB sensitivity and specificity were estimated to be 98.8% and 91.3%, respectively, while the respective estimates for ELISA were 60% and 96.7%. A sensitivity analysis, where modified prior probability distributions concerning IB diagnostic accuracy applied, showed a limited effect in posterior assessments. We concluded that ELISA can be used to screen the bulk milk and secondly, IB can be used whenever needed.