We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Pulmonary atresia and intact ventricular septum is a complex congenital heart disease with great morphological variability. Approximately two-thirds of patients may be suitable for transcatheter pulmonary valvotomy. We reviewed our experience in the use of two different percutaneous approaches to evaluate the impact on fluoroscopy time and morbidity of a new technique to perform transcatheter radiofrequency perforation and valvotomy in newborns with pulmonary atresia and intact ventricular septum.
Methods and Results
In all, 31 patients underwent radiofrequency perforation of the pulmonary valve. The first 14 infants were treated using a 5 French Judkins right coronary catheter, which was manoeuvred directly underneath the atretic pulmonary valve (Group A). The others were treated using a telescopic system consisting of Northstar Lumax Flex and White Lumax Guiding Catheters (Cook; Group B). In both groups, after radiofrequency perforation of the pulmonary valve, a 0.014-inch superfloppy guidewire was advanced into the descending aorta and balloon dilations were performed. Required fluoroscopy time was significantly lower in Group B (48.5 ± 28.1 versus 24.9 ± 14.4 minutes, respectively; p < 0.01). A higher incidence of unfavourable events including the need for early surgery was found in Group A.
Conclusion
In our experience, telescopic catheter proved to be a valid option able to decrease the fluoroscopy time of percutaneous radiofrequency perforation of pulmonary valve and consequently patients’ exposure to procedure-related risks.