We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
During left-sided breast radiotherapy, the heart is often exposed to radiation dose. Shielding can be utilised to reduce heart exposure, but compromises the dose delivered to the breast tissue and, in a proportion of patients, to the tumour bed. Deep inspiration breath hold (DIBH) can be used as a technique to move the heart away from the treatment area and thus reduce heart dose. This study examines the efficacy of the Elekta Active Breathing Coordinator (ABC), a DIBH method, in reducing heart dose.
Materials and methods
In total, 12 patients receiving radiotherapy to the left breast were planned for treatment with both a free-breathing (FB) and an ABC scan. The dose volume histogram data for the plans was analysed with respect to heart V13, V5 Gy, mean heart dose and ipsilateral lung V18 Gy. Tumour bed D98%, threshold lung volume in breath hold (BH) and the maximum BH time for each patient was also measured. Patients then received their radiotherapy treatment using the ABC plan and the systematic error in the craniocaudal, lateral and vertical axes was assessed using orthogonal imaging.
Results
The median heart V13 Gy for FB and DIBH patients was 3% (range, 0·85–11·28) and 0% (range, 0–1·56), respectively, with a mean heart dose of 2·62 Gy (range, 1·21–4·93) in FB and 1·51 Gy (range, 1·17–2·22) in ABC. The median lung V18 Gy was 8·7% (3·08–14·87) in FB plans and 9% (4·88–12·82) in ABC plans. The mean systematic set-up errors in all three planes were within the departmental set-up tolerance of 5 mm for both techniques. Median FB tumour bed D98% was 97·4% (92·8–99·5) and 97·5% (97·3–98·5) for ABC.
Conclusion
ABC represents a good method of reducing radiation dose to the heart while not compromising on dose to the tumour bed, and it has a clear advantage over FB radiotherapy in reducing the risk of cardiac toxicity. It is tolerated well by patients and does not produce any difficulties in patient positioning.