We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
In this study, we describe our experience utilising Advisor™ High Density (HD) Grid mapping catheter in transcatheter ablation of intraatrial re-entrant and focal atrial tachycardias with or without CHD.
Methods:
Forty-five consecutive patients with intraatrial re-entrant and focal atrial tachycardia who underwent a transcatheter ablation procedure by using Advisor™ HD Grid mapping catheter and high-density mapping system in our hospital from January 2017 to January 2023 were included into the study.
Results:
The mean age of the patients was 14.2 ± 7.3 years (6–32 years), and the mean weight was 48.3 ± 16.2 kg (22–83 kg). Of the total 45 patients, 21 were intraatrial re-entrant tachycardia and 25 were focal atrial tachycardia. Of the 21 re-entrant circuits, 15 were classified as cavotricuspid isthmus-dependent and 5 were non-cavotricuspid isthmus-dependent. In one patient, two re-entrant circuits were identified. A transbaffle ablation was successfully performed from the left atrium in one patient. Of the 25 focal atrial tachycardia, 19 were from right atrium and 6 were from left atrium. A cryoablation was performed in only one patient and radiofrequency ablation in others. The mean procedure time was 180 ± 64 minutes. The mean follow-up period was 69.3 ± 35.3 months. Acute success was 95.5%. Recurrence was noted in two patients (4.4%).
Conclusion:
Advisor™ HD Grid mapping catheter was found to be safe and achieved an acceptable success in transcatheter ablation of patients with intraatrial re-entrant tachycardia and focal atrial tachycardias.
Recommend this
Email your librarian or administrator to recommend adding this to your organisation's collection.